Flatfielding in spatial heterodyne spectroscopy.

Spatial heterodyne spectroscopy (SHS) is a Fourier-transform spectroscopic technique that simultaneously records all path differences using a detector array. Compared to conventional Fourier-transform spectroscopy that measures interferogram samples sequentially in the time domain, SHS is insensitive to a changing scene; however, the effects caused by differences in the detector elements and/or the optics for each sample must be addressed with a flatfield correction. The flatfield correction is typically a characteristic of the instrument and does not change with the observed scene. We present three different flatfielding approaches. Each is based on different assumptions and is applicable depending on the instrumental effects dominating the flatfield.

Journal Article↗

Correction of phase distortion in spatial heterodyne spectroscopy.

The detailed analysis of measured interferograms generally requires phase correction. Phase-shift correction methods are commonly used and well documented for conventional Fourier-transform spectroscopy. However, measured interferograms can show additional phase errors, depending on the optical path difference and signal frequency, which we call phase distortion. In spatial heterodyne spectroscopy they can be caused, for instance, by optical defects or image distortions, making them a characteristic of the individual spectrometer. They can generally be corrected without significant loss of the signal-to-noise ratio. We present a technique to measure phase distortion by using a measured example interferogram. We also describe a technique to correct for phase distortion and test its performance by using a simulation with a near-UV solar spectrum. We find that for our measured example interferogram the phase distortion is small and nearly frequency independent. Furthermore, we show that the presented phase-correction technique is especially effective for apodized interferograms.

Journal Article↗

Robust monolithic ultraviolet interferometer for the SHIMMER instrument on STPSat-1.

We describe the design, fabrication, and testing of a monolithic interferometer consisting entirely of optically contacted fused-silica optical elements that are assembled, adjusted, and permanently bonded in place. The interferometer is part of a spatial heterodyne spectrometer (SHS) [SHIMMER (Spatial Heterodyne Imager for Mesospheric Radicals)] that will be used for near-ultraviolet high-spectral-resolution limb imaging of OH solar resonance fluorescence from low Earth orbit aboard the satellite STPSat-1 scheduled for launch in 2006. The stability of the monolith coupled with the relaxed tolerances on optical quality and alignment inherent to SHS make this new instrument extremely robust and especially attractive for applications in harsh environments.

Journal Article↗

SHIMMER: a spatial heterodyne spectrometer for remote sensing of earth's middle atmosphere.

It is well known and demonstrated that interference spectroscopy offers capabilities to obtain passive remote optical sensing spectra of high precision and also achieves economies in size, cost, and ease of deployment compared with more conventional systems. We describe the development of a near-ultraviolet spatial heterodyne spectrometer designed for remote sensing of the global distribution of the hydroxyl radical OH in the Earth's middle atmosphere. The instrument, known as SHIMMER (Spatial Heterodyne Imager for Mesospheric Radicals), is expected to obtain its first OH measurement from space in early 2002 from the Space Shuttle.

Journal Article↗