PubMed Health⌕ Search

Biomedical subjects

Christophe Bailleul

Publications and source records attributed to Christophe Bailleul.

5 recordsLinked to original sources

Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy. The Resynchronization for the HemodYnamic Treatment for Heart Failure Management II implantable cardioverter defibrillator (RHYTHM II ICD) study.

BACKGROUND: The clinical value of interventricular (V-V) delay optimization in patients with chronic congestive heart failure (CHF) undergoing implantation of a device for cardiac resynchronization therapy (CRT) has not been clearly demonstrated. METHODS: RHYTHM II was a single-blind randomized trial including 121 recipients of a device for CRT with cardioverter/defibrillator capabilities (CRT-D) randomly assigned in a 1:3 ratio to simultaneous (n = 30) versus optimized (OPT) (n = 91) biventricular pacing. V-V delay was optimized by echocardiography. The study end points were (1) freedom from CRT-D system-related complications and (2) changes between preimplant and 6 months of follow-up in (a) New York Heart Association CHF functional class, (b) distance covered during a 6-minute hall walk, and (c) quality of life (QOL). RESULTS: In the OPT group, the V-V delay ranged from 0 to 80 milliseconds, with 28.4% of patients stimulated at an OPT V-V delay of 0 milliseconds. The overall 6-month survival free of adverse events requiring invasive interventions was 81.8%. In the whole cohort, 6 months of CRT-D was associated with a significant decrease in New York Heart Association class, increase in the distance covered during the 6-minute hall walk, and improvement in QOL (each P < .0001). The effects of CRT-D on these end points were similar in both study groups. CONCLUSIONS: Cardioverter-defibrillator capabilities was associated with a significant alleviation of CHF symptoms, increase in functional capacity, and improvement in QOL. The optimization of the V-V delay conferred no additional benefit compared with simultaneous biventricular stimulation.

Aged↗

Biventricular stimulation to prevent cardiac desynchronization: rationale, design, and endpoints of the 'Biventricular Pacing for Atrioventricular Block to Prevent Cardiac Desynchronization (BioPace)' study.

Despite the deleterious effects of cardiac dyssynchrony and the positive effects of cardiac resynchronization therapy, patients with high-degree atrioventricular block continue to receive desynchronizing right ventricular (RV) pacing systems. Although it is unclear whether the negative effects of RV pacing and left bundle branch block (LBBB) are comparable, and whether they depend on the presence and the degree of structural heart disease, one may hypothesize that RV pacing may have similar effects to LBBB. In the BioPace trial, the long-term effects of RV pacing vs. biventricular pacing will be prospectively compared in 1200 pacemaker patients with high likelihood of mostly paced ventricular events, regardless of whether in sinus rhythm or in atrial fibrillation (AF). After echocardiographic examination of left ventricular (LV) function, patients will be randomly assigned to the implantation of an RV vs. a biventricular pacing system and followed for up to 5 years. Primary study endpoints are survival, quality of life (QoL), and the distance covered in a 6-min hall walk (6-MHW) at 24 months after implantation. Secondary endpoints are QoL and the 6-MHW result at 12 months after implantation, hospitalization rate, LV dimensions, LV ejection fraction, and the development of chronic AF and other adverse events.

Cardiac Pacing, Artificial↗

Long-term improvements in quality of life by biventricular pacing in patients with chronic heart failure: results from the Multisite Stimulation in Cardiomyopathy study (MUSTIC).

To assess the impact of biventricular pacing on quality of life over 12 months of follow-up, 76 patients in the MUSTIC trial were evaluated by 2 instruments: The Minnesota Living with Heart Failure Questionnaire and the Karolinska Quality of Life Questionnaire. MUSTIC is a randomized, controlled study to evaluate the effects of biventricular pacing in patients in New York Heart Association class III heart failure with intraventricular conduction delay. Following a single, blind, crossover comparison of 3 months of biventricular pacing to inactive pacing (sinus rhythm group) or ventricular-inhibited pacing (atrial fibrillation group), 85% of patients preferred and were programmed to biventricular pacing and were followed for 12 months. In parallel with clinical improvements, substantial benefits in quality of life for most broad domains of quality of life and cardiovascular symptoms were found during biventricular pacing already within the crossover phase with a maintained benefit over the 12-month follow-up. Biventricular pacing improved quality of life in patients with heart failure and intraventricular conduction delays. The benefits were sustained over 12 months of follow-up.

Aged↗

Long-term benefits of biventricular pacing in congestive heart failure: results from the MUltisite STimulation in cardiomyopathy (MUSTIC) study.

OBJECTIVES: The main objective of this study was to assess if the benefits of biventricular (BiV) pacing observed during the crossover phase were sustained over 12 months. BACKGROUND: MUltisite STimulation In Cardiomyopathies (MUSTIC) is a randomized controlled study intended to evaluate the effects of BiV pacing in patients with New York Heart Association (NYHA) class III heart failure and intraventricular conduction delay. METHODS: Of 131 patients included, 42/67 in sinus rhythm (SR) and 33/64 in atrial fibrillation (AF) were followed up longitudinally at 9 and 12 months by 6-min walked distance, peak oxygen uptake (peak VO(2)), quality of life by the Minnesota score, NYHA class, echocardiography, and left ventricular ejection fraction by radionuclide technique. RESULTS: At 12 months, all SR and 88% of AF patients were programmed to BiV pacing. Compared with baseline, the 6-min walked distance increased by 20% (SR) (p = 0.0001) and 17% (AF) (p = 0.004); the peak VO(2) by 11% (SR) and 9% (AF); quality of life improved by 36% (SR) (p = 0.0001) and 32% (AF) (p = 0.002); NYHA class improved by 25% (SR) (p = 0.0001) and 27% (AF) (p = 0.0001). The ejection fraction improved by 5% (SR) and 4% (AF). Mitral regurgitation decreased by 45% (SR) and 50% (AF). CONCLUSIONS: The clinical benefits of BiV pacing appeared to be significantly maintained over a 12-month follow-up period.

Aged↗