PubMed Health⌕ Search

Biomedical subjects

Christophe D Masselon

Publications and source records attributed to Christophe D Masselon.

9 recordsLinked to original sources

High throughput quantitative analysis of serum proteins using glycopeptide capture and liquid chromatography mass spectrometry.

It is expected that the composition of the serum proteome can provide valuable information about the state of the human body in health and disease and that this information can be extracted via quantitative proteomic measurements. Suitable proteomic techniques need to be sensitive, reproducible, and robust to detect potential biomarkers below the level of highly expressed proteins, generate data sets that are comparable between experiments and laboratories, and have high throughput to support statistical studies. Here we report a method for high throughput quantitative analysis of serum proteins. It consists of the selective isolation of peptides that are N-linked glycosylated in the intact protein, the analysis of these now deglycosylated peptides by liquid chromatography electrospray ionization mass spectrometry, and the comparative analysis of the resulting patterns. By focusing selectively on a few formerly N-linked glycopeptides per serum protein, the complexity of the analyte sample is significantly reduced and the sensitivity and throughput of serum proteome analysis are increased compared with the analysis of total tryptic peptides from unfractionated samples. We provide data that document the performance of the method and show that sera from untreated normal mice and genetically identical mice with carcinogen-induced skin cancer can be unambiguously discriminated using unsupervised clustering of the resulting peptide patterns. We further identify, by tandem mass spectrometry, some of the peptides that were consistently elevated in cancer mice compared with their control littermates.

Animals↗

Tailored noise waveform/collision-induced dissociation of ions stored in a linear ion trap combined with liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry.

A new collision-induced dissociation (CID) technique based on broadband tailored noise waveform (TNW) excitation of ions stored in a linear ion trap has been developed. In comparison with the conventional sustained off-resonance irradiation (SORI) CID method commonly used in Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), this MS/MS technique increases throughput by eliminating the long pump-down delay associated with gas introduction into the high vacuum ICR cell region. In addition, the TNW-CID method speeds spectrum acquisition since it does not require Fourier transformation, calculation of resonant frequencies and generation of the excitation waveforms. We demonstrate TNW-CID coupled with on-line capillary reverse-phase liquid chromatography separations for the identification of peptides. The experimental results are compared with data obtained using conventional quadrupole ion trap MS/MS and SORI-CID MS/MS in an ICR cell.

Amino Acid Sequence↗

FTICR mass spectrometry for qualitative and quantitative bioanalyses.

Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is playing an increasing role in the characterization of cellular systems owing to its capabilities for providing higher confidence of identification, increased dynamic range and sensitivity unmatched by other MS platforms. Particularly in proteomics, where global and quantitative approaches are essential, the attributes of FTICR-MS are poised to make significant contributions. Recent advances in the field that have particular importance for proteomic applications include the use of high-performance micro-capillary column separation techniques coupled to FTICR, as well as methods that improve protein identification, sensitivity, dynamic range and throughput.

Animals↗

Collisional activation of ions in RF ion traps and ion guides: the effective ion temperature treatment.

Ion transfer and storage using inhomogeneous radio frequency (RF) electric fields in combination with gas-assisted ion cooling and focusing constitutes one of the basic techniques in mass spectrometry today. The RF motion of ions in the bath gas environment involves a large number of ion-neutral collisions that leads to the internal activation of ions and their effective "heating" (when a thermal distribution of internal energies results). The degree of ion activation required in various applications may range from a minimum level (e.g., slightly raising the average internal energy) to an intense level resulting in ion fragmentation. Several research groups proposed using the effective temperature as a measure of ion activation under conditions of multiple ion-neutral collisions. Here we present approximate relationships for the effective ion temperature relevant to typical operation modes of RF multipole devices. We show that RF ion activation results in near-thermal energies for ions occupying an equilibrium position at the center of an RF trap, whereas increased ion activation can be produced by shifting ions off-center, e.g., by means of an external DC electric field. The ion dissociation in the linear quadrupole ion trap using the dipolar DC ion activation has been observed experimentally and interpreted in terms of the effective ion temperature.

Fibrinopeptide A↗

Integration of electrokinetic-based multidimensional separation/concentration platform with electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry for proteome analysis of Shewanella oneidensis.

This work focuses on the development of a multidimensional electrokinetic-based separation/concentration platform coupled with electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS) for achieving the high resolution and ultrasensitive analysis of complex protein/peptide mixtures. A microdialysis junction is employed as the interface for on-line combination of capillary isoelectric focusing (CIEF) with transient capillary isotachophoresis/zone electrophoresis (CITP/CZE) in an integrated platform. Besides the excellent resolving power afforded by both CIEF and CZE separations, the electrokinetic focusing/stacking effects of CIEF and CITP greatly enhance the dynamic range and detection sensitivity of MS for protein identification. The constructed multidimensional separation/concentration platform is demonstrated for the analysis of Shewanella oneidensis proteome, which has considerable implications toward the bioremediation of environmental pollutants. The electrokinetic-based platform offers the overall peak capacity comparable to those obtained using multidimensional chromatography systems, but with a much shorter run time and no need for column regeneration. Most importantly, a total of 1174 unique proteins, corresponding to 26.5% proteome coverage, are identified from the cytosolic fraction of S. oneidensis, while requiring <500 ng of proteolytic digest loaded in the CIEF capillary. The ultrasensitive capabilities of electrokinetic-based proteome approach are attributed to the concentration effect in CIEF, the electrokinetic stacking of CITP, the nanoscale peak volume in CZE, the "accurate mass tag" strategy for protein/peptide identification, and the high-sensitivity, high-resolution, and high-mass measurement accuracy of FTICR-MS.

Amino Acid Sequence↗

Gene expression profiling using advanced mass spectrometric approaches.

In the era of systems biology, computational and high-throughput experimental biological approaches are increasingly being combined to provide global snapshots of entire genomes and proteomes under tissue- and disease-specific conditions. The aim is to identify proteins changing in concentration and/or post-translational state and/or location, and develop a better molecular level understanding of the operation of biological systems. Here we describe an approach for comparative proteomics that builds upon the combination of high-performance nano-scale separations with the high-mass measurement accuracy, mass-resolving power and sensitivity of Fourier transform ion cyclotron resonance mass spectrometry to provide broad dynamic range, comprehensive and quantitative proteome measurements.

Amino Acid Sequence↗

ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation.

Data-dependent external m/z selection and accumulation of ions is demonstrated in use with ESI-FTICR instrumentation, with two different methods for ion selection being explored. One method uses RF/DC quadrupole filtering and is described in use with an 11.5 tesla (T) FTICR instrument, while the second method employs RF-only resonance dipolar excitation selection and is described in use with a 3.5 T FTICR instrument. In both methods ions are data-dependently selected on the fly in a linear quadrupole ion guide, then accumulated in a second linear RF-only quadrupole trap that immediately follows. A major benefit of ion preselection prior to external accumulation is the enhancement of ion populations for low-level species. This development is expected to expand the dynamic range and sensitivity of FTICR for applications including analysis of complex polypeptide mixtures (e.g., proteomics).

Journal Article↗

Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectra.

We have obtained relationships for frequency shifts resulting from the interference of spectral components for the magnitude mode Fourier transform. The approximation of a weak perturbation of well resolved peaks has been used. Both the low- and high-pressure limits for Fourier-transform ion cyclotron resonance (FTICR) operation have been considered. We have found that the shifts can be either negative or positive, depending on the initial phase and/or the choice of the time-domain interval. The magnitude of shifts generally does not exceed the peak width. In the approximation of small perturbations the shifts produced by multiple peaks are additive. We have compared theoretical results with experimental shifts for isotopic clusters of multiply charged insulin. Up to 1 ppm frequency variations were experimentally observed for the insulin 5+ charge state, consistent with theoretical estimates. The peak interference is of particular significance in the case of bio-molecular mass spectra having a large number of peaks and covering a considerable dynamic range (i.e., relative abundance). We conclude that the common mass measurement procedure based on the location of the magnitude mode maxima of well resolved peaks can result in systematic mass measurement errors. The relationships obtained provide corrections for the frequency shifts and thus improve the mass measurement accuracy.

Algorithms↗

Enrichment of integral membrane proteins for proteomic analysis using liquid chromatography-tandem mass spectrometry.

An increasing number of proteomic strategies rely on liquid chromatography-tandem mass spectrometry (LC-MS/MS) to detect and identify constituent peptides of enzymatically digested proteins obtained from various organisms and cell types. However, sample preparation methods for isolating membrane proteins typically involve the use of detergents and chaotropes that often interfere with chromatographic separation and/or electrospray ionization. To address this problem, a sample preparation method combining carbonate extraction, surfactant-free organic solvent-assisted solubilization, and proteolysis was developed and demonstrated to target the membrane subproteome of Deinococcus radiodurans. Out of 503 proteins identified, 135 were recognized as hydrophobic on the basis of their calculated hydropathy values (GRAVY index), corresponding to coverage of 15% of the predicted hydrophobic proteome. Using the PSORT algorithm, 53 of the proteins identified were classified as integral outer membrane proteins and 215 were classified as integral cytoplasmic membrane proteins. All identified integral cytoplasmic membrane proteins had from 1 to 16 mapped transmembrane domains (TMDs), and 65% of those containing four or more mapped TMDs were identified by at least one hydrophobic membrane spanning peptide. The extensive coverage of the membrane subproteome (24%) by identification of highly hydrophobic proteins containing multiple TMDs validates the efficacy of the described sample preparation technique to isolate and solubilize hydrophobic integral membrane proteins from complex protein mixtures.

Amino Acid Sequence↗