PubMed Health⌕ Search

Biomedical subjects

Christopher F Beaulieu

Publications and source records attributed to Christopher F Beaulieu.

At least 19 recordsLinked to original sources

Surface normal overlap: a computer-aided detection algorithm with application to colonic polyps and lung nodules in helical CT.

We developed a novel computer-aided detection (CAD) algorithm called the surface normal overlap method that we applied to colonic polyp detection and lung nodule detection in helical computed tomography (CT) images. We demonstrate some of the theoretical aspects of this algorithm using a statistical shape model. The algorithm was then optimized on simulated CT data and evaluated using a per-lesion cross-validation on 8 CT colonography datasets and on 8 chest CT datasets. It is able to achieve 100% sensitivity for colonic polyps 10 mm and larger at 7.0 false positives (FPs)/dataset and 90% sensitivity for solid lung nodules 6 mm and larger at 5.6 FP/dataset.

Algorithms↗

Automatic detection and classification of hypodense hepatic lesions on contrast-enhanced venous-phase CT.

The objective of this work was to develop and validate algorithms for detection and classification of hypodense hepatic lesions, specifically cysts, hemangiomas, and metastases from CT scans in the portal venous phase of enhancement. Fifty-six CT sections from 51 patients were used as representative of common hypodense liver lesions, including 22 simple cysts, 11 hemangiomas, 22 metastases, and 1 image containing both a cyst and a hemangioma. The detection algorithm uses intensity-based histogram methods to find central lesions, followed by liver contour refinement to identify peripheral lesions. The classification algorithm operates on the focal lesions identified during detection, and includes shape-based segmentation, edge pixel weighting, and lesion texture filtering. Support vector machines are then used to perform a pair-wise lesion classification. For the detection algorithm, 80% lesion sensitivity was achieved at approximately 0.3 false positives (FP) per slice for central lesions, and 0.5 FP per slice for peripheral lesions, giving a total of 0.8 FP per section. For 90% sensitivity, the total number of FP rises to about 2.2 per section. The pair-wise classification yielded good discrimination between cysts and metastases (at 95% sensitivity for detection of metastases, only about 5% of cysts are incorrectly classified as metastases), perfect discrimination between hemangiomas and cysts, and was least accurate in discriminating between hemangiomas and metastases (at 90% sensitivity for detection of hemangiomas, about 28% of metastases were incorrectly classified as hemangiomas). Initial implementations of our algorithms are promising for automating liver lesion detection and classification.

Algorithms↗

Asymmetric closure of ischiopubic synchondrosis in pediatric patients: correlation with foot dominance.

OBJECTIVE: The enlarged ischiopubic synchondrosis is a well-known anatomic structure; however, little is known about its physiology. In early childhood, enlargement of this synchondrosis occurs bilaterally, whereas before complete ossification, it is frequently found unilaterally. In most children, the unilateral enlarged ischiopubic synchondrosis is observed in the left hemipelvis, a finding that was hitherto unexplained. During common athletic activities, increased ground reaction forces are exerted on the weight-bearing nondominant limb, which in up to 87% of the general population is the left leg. The asymmetric exertion of these forces may explain the distinct closure sequence of this temporary joint. The purpose of this study was to correlate unilateral enlarged ischiopubic synchondrosis with foot dominance. MATERIALS AND METHODS: The study cohort comprised 32 children who had undergone unenhanced radiography, CT, or MRI for reasons other than bone disorders and who presented with enlarged ischiopubic synchondroses. In these children, the distribution of enlarged ischiopubic synchondrosis and foot dominance were evaluated either retrospectively (n = 11) or prospectively (n = 21). RESULTS: In this cohort, 78% of patients were right-footed and 22% were left-footed. Nine of the 32 children presented with unilateral enlarged ischiopubic synchondrosis (left, seven [78%] of nine; right, two [22%] of nine). All children with enlarged left ischiopubic synchondrosis were right-footed, and all children with enlarged right ischiopubic synchondrosis were left-footed. CONCLUSION: Unilateral enlarged ischiopubic synchondrosis is closely correlated with foot dominance. The asymmetric ossification pattern of the ischiopubic synchondrosis indicates delayed ossification of this anatomic structure due to asymmetrically applied mechanical forces to the nondominant limb.

Adolescent↗

Circular tomosynthesis: potential in imaging of breast and upper cervical spine--preliminary phantom and in vitro study.

Phantom and in vitro studies were performed to evaluate the potential application of digital circular tomosynthesis in imaging of the breast and upper cervical spine. A prototype volumetric x-ray system was used to image a mammographic phantom, a fresh mastectomy specimen, and a head phantom containing the upper cervical spine. Results show that breast tissue visualization is improved by the ability to produce sectional images that blur overlying structures and yield three-dimensional information about calcification clusters. In upper cervical spine imaging, digital circular tomosynthesis effectively blurs overlying jaw and skull structures so that C1 and C2 can be visualized in a standard anteroposterior view.

Cervical Vertebrae↗

Comparison of new sequences for high-resolution cartilage imaging.

The high prevalence of osteoarthritis continues to demand improved accuracy in detecting cartilage injury and monitoring its response to different treatments. MRI is the most accurate noninvasive method of diagnosing cartilage lesions. However, MR imaging of cartilage is limited by scan time, signal-to-noise ratio (SNR), and image contrast. Recently, there has been renewed interest in SNR-efficient imaging sequences for imaging cartilage, including various forms of steady-state free-precession as well as driven-equilibrium imaging. This work compares several of these sequences with existing methods, both theoretically and in normal volunteers. Results show that the new steady-state methods increase SNR-efficiency by as much as 30% and improve cartilage-synovial fluid contrast by a factor of three. Additionally, these methods markedly decrease minimum scan times, while providing 3D coverage without the characteristic blurring seen in fast spin-echo images.

Cartilage↗

Protocols in sports magnetic resonance imaging.

Magnetic resonance imaging, with its multiplanar imaging capability and superior soft-tissue contrast, has become the preferred method for imaging sports-related injuries. Advances in gradient technology, receiver coils, and imaging software have allowed the imaging of the injured athlete to take place quickly and at high resolution. Understanding the tissues being imaged, the underlying anatomy, and the capabilities of today's scanners is crucial to the design of intelligent and efficient protocols.

Athletic Injuries↗

Interactive and interventional sports medicine imaging.

The concepts and clinical potential of interactive magnetic resonance imaging (MRI) in which an examiner manipulates the joint of interest during MRI, and of interventional sports medicine imaging in which radiological guidance is used for targeted therapy of injuries and masses are described. As illustrated by a series of clinical cases, we believe that with further development, interactive MRI will play an important role in the comprehensive evaluation of patients with shoulder pain or dysfunction as well as other joint derangements. Interventional sports medicine takes advantage of the increasingly sophisticated diagnostic value of MRI and the radiologist's ability to use imaging to guide percutaneous therapy. We review our recent experience treating a wide variety of disorders such as cysts, hematomas, and inflammatory disorders, focusing on techniques utilizing ultrasound and MR guidance.

Adolescent↗

The effect of pronation and supination on the minimally displaced scaphoid fracture.

The amount of rotation that occurs at the scaphoid waist fracture site with pronation and supination of the forearm is studied in 10 upper extremities from cadavers. Two colinear metal markers were placed in the osteotomized scaphoid and a below-the-elbow cast was applied. Spiral volumetric computed tomography scanning of the scaphoid was done with multiplanar reformation to evaluate displacement of the metal markers. Four of the 10 specimens also were studied without any immobilization. The total magnitude of motion from pronation to supination averaged 0.2 mm in the specimens with a below-the-elbow thumb spica cast, and 2.4 mm in specimens without immobilization. The current study showed no significant rotation at the minimally displaced scaphoid waist fracture site during pronation and supination in a below-the-elbow cast. Furthermore, there is unacceptable rotation at the fracture site in the absence of a cast. Based on this study, a below-the-elbow thumb spica cast seems adequate for fracture immobilization; however, clinical correlation is needed.

Cadaver↗

CT colonography: does improved z resolution help computer-aided polyp detection?

Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners.

Colon↗

Magnetic resonance imaging in diagnosis of chronic posterolateral rotatory instability of the elbow.

Posterolateral rotatory instability of the elbow can be difficult to diagnose and requires a high degree of clinical suspicion. Cases of chronic posterolateral rotatory instability (symptoms present more than 1 year) may be an even more perplexing subgroup. This is a case report of a patient with a 30-year history of intermittent elbow instability. Clinical examination was equivocal, and magnetic resonance imaging was unable to define any ligamentous injury around the elbow. Examination under anesthesia and surgical findings were consistent with complete disruption of the lateral ulnar collateral ligament. The 12-month follow-up after surgical reconstruction showed complete resolution of symptoms. Posterolateral rotatory instability is a diagnosis largely made by examination under anesthesia. A thorough history and a high clinical suspicion are necessary to support the physician's decision to place the patient under anesthesia. Confirmation of a chronic tear of the lateral ulnar collateral ligament of the elbow with magnetic resonance imaging can be difficult and sometimes misleading.

Adult↗

Edge displacement field-based classification for improved detection of polyps in CT colonography.

Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and less invasive alternative to FOC. It would be desirable to have computer-aided detection (CAD) algorithms to examine the large amount of data CTC provides. Most current CAD algorithms have high false positive rates at the required sensitivity levels. We developed and evaluated a postprocessing algorithm to decrease the false positive rate of such a CAD method without sacrificing sensitivity. Our method attempts to model the way a radiologist recognizes a polyp while scrolling a cross-sectional plane through three-dimensional computed tomography data by classification of the changes in the location of the edges in the two-dimensional plane. We performed a tenfold cross-validation study to assess its performance using sensitivity/specificity analysis on data from 48 patients. The mean specificity over all experiments increased from 0.19 (0.35) to 0.47 (0.56) for a sensitivity of 1.00 (0.95).

Adult↗

Quantification of distention in CT colonography: development and validation of three computer algorithms.

Three bowel distention-measuring algorithms for use at computed tomographic (CT) colonography were developed, validated in phantoms, and applied to a human CT colonographic data set. The three algorithms are the cross-sectional area method, the moving spheres method, and the segmental volume method. Each algorithm effectively quantified distention, but accuracy varied between methods. Clinical feasibility was demonstrated. Depending on the desired spatial resolution and accuracy, each algorithm can quantitatively depict colonic diameter in CT colonography.

Algorithms↗

Automated generation of curved planar reformations from volume data: method and evaluation.

The authors developed and evaluated a method to automatically create interactive vascular curved planar reformations with computed tomographic (CT) angiographic data. The method decreased user interaction time by 86%, from 15 to 2 minutes. Expert reviewers were asked to indicate their confidence in differentiating automatically created images from clinical-quality manually produced images. The area under the receiver operating characteristic curve was 0.45 (95% CI: 0.39, 0.51), and a test of equivalency indicated that reviewers could not distinguish between images. They also graded image quality as equivalent to that with manual methods and found fewer artifacts on automatically created images. Automatic methods rapidly produce curved planar reformations of equivalent quality with reduced time and effort.

Humans↗

Interventional musculoskeletal procedures performed by using MR imaging guidance with a vertically open MR unit: assessment of techniques and applicability.

PURPOSE: To evaluate the safety of and time required for a broad range of musculoskeletal interventional procedures performed by using magnetic resonance (MR) imaging guidance with a vertically open 0.5-T unit. MATERIALS AND METHODS: Sixty-three MR imaging-guided procedures were performed. A vertically open MR unit equipped with in-room display monitors allowed interactive freehand MR guidance predominantly with fast spin-echo and gradient-echo sequences. Each procedure was classified in terms of the anatomic location, procedure type, and tissue type involved. The procedures were evaluated for success of needle placement, adequacy of tissue sampling, total procedural time, needle time, number of needle passes, and complications. RESULTS: Procedures consisted of tissue sampling with core-needle (n = 6) or fine-needle aspiration (n = 20) biopsy, corticosteroid or contrast agent injection (n = 19), joint cyst aspiration (n = 7), and drainage (n = 11). Successful needle placement was achieved in all 63 cases. Cytologic and histologic tissue samples were sufficient for pathologic diagnosis in 24 of 26 cases. In two cases, complications occurred: transient local bleeding and a brief vasovagal episode. The mean total procedural time was 64.8 minutes; the mean needle time, 26.2 minutes; and the mean number of needle passes per patient, 1.6. CONCLUSION: With use of a vertically open MR unit, MR-guided interventional procedures involving bone, soft tissue, intervertebral disks, and joints are safe and sufficiently rapid for use in clinical practice.

Adult↗

Isoattenuating pancreatic adenocarcinoma at multi-detector row CT: secondary signs.

PURPOSE: To assess the frequency of isoattenuating pancreatic adenocarcinoma with multi-detector row computed tomography (CT) and determine whether there are specific secondary signs that aid in detection. MATERIALS AND METHODS: Fifty-three patients with pancreatic adenocarcinoma underwent contrast material-enhanced biphasic multi-detector row CT with curved planar reformation. Tumors were initially deemed isoattenuating or hypoattenuating to normal pancreatic parenchyma on the basis of visual inspection, and the degree of attenuation was confirmed by calculating the mean attenuation differences between normal pancreatic parenchyma and tumor (tumor-pancreas contrast) during the pancreatic phase. Indirect signs of pancreatic tumor were tabulated in patients with an isoattenuating tumor. RESULTS: Of the 53 patients, six (11%) had isoattenuating tumors with a mean tumor-pancreas contrast of 9.25 HU +/- 11.3 during the pancreatic phase and 4.15 HU +/- 8.5 during the portal venous phase. The secondary signs of pancreatic tumor in these six patients included an interrupted pancreatic duct (n = 5), dilated biliary and pancreatic ducts (n = 1), atrophic distal pancreatic parenchyma (n = 3), and mass effect and/or convex contour abnormality (n = 3). The mean tumor-pancreas contrast for the remaining 47 patients was 74.76 HU +/- 35.61 during the pancreatic phase. CONCLUSION: With no visible tumor-pancreas contrast for isoattenuating tumors, indirect signs such as mass effect, atrophic distal parenchyma, and an interrupted duct sign are important indicators for the presence of tumor.

Adenocarcinoma↗

Local staging of pancreatic carcinoma with multi-detector row CT: use of curved planar reformations initial experience.

PURPOSE: To evaluate the utility of curved planar reformations compared with standard transverse images in the assessment of pancreatic tumors. MATERIALS AND METHODS: Forty-three patients suspected of having pancreatic tumors underwent contrast material-enhanced biphasic multi-detector row computed tomography (CT). Curved planar reformations were generated along the pancreatic duct, common bile duct, and major mesenteric vessels. Three blinded independent readers assessed the curved planar reformations and transverse images separately for the presence of tumor, resectability, and vascular involvement. The results were compared with those of a consensus panel who evaluated the curved planar reformations and transverse images together along with clinical data and surgical findings. RESULTS: Of 43 patients, 20 had pancreatic malignancies as judged by the consensus panel and proven at biopsy and/or clinical follow-up. For tumor detection, transverse images and curved planar reformations had an average sensitivity of 95.0% and 98.4% (P >.05), respectively, and an average specificity of 90.9% and 91.3% (P >.05), respectively. For tumor resectability, transverse images and curved planar reformations had an average sensitivity of 85.7% and 71.4% (P >.05), respectively, and an average specificity of 85.2% and 84.3% (P >.05), respectively. Average interpretation time was 6.4 minutes with transverse images and 4.1 minutes with curved planar reformations. CONCLUSION: Curved planar reformations are equivalent to transverse images in the detection of pancreatic tumors and determination of surgical resectability.

Adenocarcinoma↗

Computed tomography colonography: feasibility of computer-aided polyp detection in a "first reader" paradigm.

OBJECTIVE: : To determine the feasibility of a computer-aided detection (CAD) algorithm as the "first reader" in computed tomography colonography (CTC). METHODS: : In phase 1 of a 2-part blind trial, we measured the performance of 3 radiologists reading 41 CTC studies without CAD. In phase 2, readers interpreted the same cases using a CAD list of 30 potential polyps. RESULTS: : Unassisted readers detected, on average, 63% of polyps > or =10 mm in diameter. Using CAD, the sensitivity was 74% (not statistically different). Per-patient analysis showed a trend toward increased sensitivity for polyps > or =10 mm in diameter, from 73% to 90% with CAD (not significant) without decreasing specificity. Computer-aided detection significantly decreased interobserver variability (P = 0.017). Average time to detection of the first polyp decreased significantly with CAD, whereas total reading case reading time was unchanged. CONCLUSION: : Computer-aided detection as a first reader in CTC was associated with similar per-polyp and per-patient detection sensitivity to unassisted reading. Computer-aided detection decreased interobserver variability and reduced the time required to detect the first polyp.

Adult↗