PubMed Health⌕ Search

Biomedical subjects

Christopher Gebert

Publications and source records attributed to Christopher Gebert.

3 recordsLinked to original sources

The morphology and biomechanical characteristics of subcutaneously implanted tissue-engineered human septal cartilage.

The purpose of the study was to examine the morphology and biomechanical characteristics of in vivo cultured tissue-engineered human septal cartilage as a prospective autogenous transplant material for subcutaneous implantation in reconstructive procedures. Chondrocytes were enzymatically isolated from human septal cartilage biopsies. The cell number was expanded in monolayer culture. Chondrocytes were then fixed on a non-woven poly-lactide-poly-glycolide (PGLA) polymer scaffold by means of fibrin glue. The PGLA-polymer construct was implanted subcutaneously on the back of athymic mice and allowed to mature for 6 or 12 weeks. After killing the mice, the formed cartilage was tested on a material testing machine with a highly standardized reproducible setting. Biomechanical testing consisted of an indentation test, which revealed the failure load and compressive modulus of the neocartilage. The failure load shows the upper limit of supported stress. The compressive modulus is a measure of the templates' stiffness. After testing, the templates were histologically stained. Native human septal cartilage served as a control group. Histological and macroscopic examination showed cartilage formation of a hyaline-like morphology. Histological staining revealed the synthesis of abundant mucopolysaccharid matrix. The biomechanical characteristics of neocartilage proved to be of no statistical difference compared to native human septal cartilage. The failure load and compressive modulus were initially somewhat lower and reached the control group's results after 12 weeks in-vivo. Summarizing, tissue engineered nasal cartilage matches typical mechanical characteristics of native hyaline cartilage. Its elasticity and failure load are of sufficient quality to meet the clinical requirements for reconstructive surgery.

Animals↗

Creating artificial perichondrium by polymer complex membrane macroencapsulation: immune protection and stabilization of subcutaneously transplanted tissue-engineered cartilage.

Functional organ or tissue failure is one of the most frequent, devastating and costly problems in modern health care. The field of tissue engineering has tremendous potential for developing new functional tissue. In reconstructive surgery, cartilage engineering could be a serious alternative to the established method of autologous cartilage transplantation. Recent studies demonstrate cartilage engineering by subcutaneous implantation of chondrocyte-seeded PGA/PLA-fibrin glue scaffolds in the backs of nude mice. In both autologous cartilage transplantation and cartilage engineering, the host immune response affects transplant integrity and cartilage morphology to an unforeseeable extent. To investigate whether polyelectrolyte complex (PEC) membranes can prevent rejection of cartilage transplants without neglecting tissue metabolism, tissue-engineered cartilage encapsulated with a PEC membrane was subcutaneously implanted in the backs of nude mice. Non-encapsulated tissue-engineered cartilage was used for the control group. Histochemistry and scanning electron microscopy were performed 4 and 12 weeks after implantation. There was no interaction between the host and the implant with an intact PEC membrane. With protection by PEC encapsulation, implanted tissue-engineered cartilage showed no signs of degeneration and had a significantly weaker cellular immune response than without it. Thus, PEC membrane encapsulation appears to be a novel approach for protecting cartilage implants from host immune response after autologous transplantation.

Animals↗

A tissue-engineering model for the manufacture of auricular-shaped cartilage implants.

The established surgical methods of external ear reconstruction using autogenous tissue represent the current state of the art. Because of the limited possibilities for shaping conventional harvested autogenous rib cartilage, the cosmetic results of auricular reconstruction are frequently unsatisfactory. Tissue engineering could represent an alternative technique for obtaining a precisely shaped cartilage implant that avoids donor site morbidity and unsatisfactory cosmetic results. In this study, the reliability and quality of a tissue-engineering model for the manufacture of auricular-shaped human cartilage implants was investigated, focusing on the feasibility of the manufacturing process and the in vivo and in vitro maturation of an extracellular cartilage-like matrix. Implants were molded within an auricular-shaped silicone cylinder, and human nasal septal chondrocytes crosslinked by human fibrin within bioresorbable PGLA-PLLA polymer scaffolds were used. After an in vitro incubation of up to 6 weeks, defined fragments of the prefabricated auricular-shaped construct were implanted subcutaneously on the backs of nude mice for at least 6 to 12 weeks ( n=7). Scaffolds without cell loading served as controls. Macroscopic and histochemical examination after 3 and 6 weeks in vitro showed a solid compound of homogenously distributed chondrocytes within the polymer scaffold, leading only to a limited pericellular matrix formation. Analysis after 6 and 12 weeks of in vivo maturation demonstrated a solid tissue compound and neocartilage formation with the presence of cartilage-specific matrix components. Implants obtained shape and size during the entire period of implantation. The model of cartilage implant manufacturing presented here meets all biocompatible requirements for in vitro prefabrication and in vivo maturation of autogenous, individually shaped cartilage transplants.

Animals↗