PubMed Health⌕ Search

Biomedical subjects

Christopher Herzog

Publications and source records attributed to Christopher Herzog.

At least 19 recordsLinked to original sources

Acute abdomen: Added diagnostic value of coronal reformations with 64-slice multidetector row computed tomography.

RATIONALE AND OBJECTIVES: We sought to assess retrospectively the added value of coronal reformations from isotropic voxels obtained with 64-slice multidetector row computed tomography (CT) of the acute abdomen. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board and informed consent was waived. Multidetector helical 64-section CT (section thickness, 0.6 mm; pitch 1.75; table speed 35 mm/sec) was performed in 100 patients (60 women and 40 men; age range, 9-/+85 years; mean age, 45.2 years) with acute nontraumatic abdominal pain who had been referred from the emergency department. Axial images were reconstructed with 5-mm-thick sections at 5-mm intervals. The second data set was reformatted coronally, with 3-mm-thick sections at 3-mm intervals. Four independent, blinded readers with various level of training interpreted first the axial scans alone and then followed immediately by the coronal scans. Confidence in the visualization of anatomy and pathology was scored on a 5-point scale. The final diagnosis was determined by surgical and pathologic reports and by clinical follow-up in those who did not undergo surgery. RESULTS: Based upon the individual patient's clinical history and other comorbid factors, 92 patients received intravenous contrast and 90 patients received oral contrast. In 45 patients, no CT abnormalities were detected for an explanation of the abdominal pain. Mean sensitivity and specificity of axial CT alone were 92.5% and 91%, respectively. No significant differences in sensitivity and specificity were observed for the use of combined axial and coronal images. For the most inexperienced reader, the coronal reformations were helpful in 95% of cases, while for the most experienced reader, the coronal reformations were helpful in 35% of the cases. The coronal images were deemed helpful in an average of 62.3% of the cases for the four readers. However, diagnosing subtle pathology in the abdominal wall was difficult on coronal reformations alone. Overall, coronal reformations improved diagnostic confidence and interobserver agreement over axial images alone for visualization of normal abdominal structures and in the diagnosis of abdominal pathology. CONCLUSION: Axial and coronal reformations of 64-section multidetector row CT have equal sensitivity and specificity for the diagnosis of acute abdominal pathology. However, coronal reformations improved the diagnostic confidence for all readers but most significantly for the least experienced. Therefore, radiology departments with residents should consider routinely generating coronal images in patients with acute abdominal pain.

Abdomen, Acute↗

MR-compatible assistance system for punction in a high-field system: device and feasibility of transgluteal biopsies of the prostate gland.

We present the first cadavic study results concerning the feasibility of the use of an MR-guided assistance system, Innomotion (Innomedic, Herxheim, Germany), for accurate and consistent placement of percutaneous needles in the prostate gland. The MR-compatible assistance system consists of a C-arch, guiding arm and application module (AMO). T1-weighted fast low angle shot (FLASH) 2-D-GRE sequence (TR/TE=110/4 ms) and T2-weighted turbo spin-echo (TSE)-sequences (TR/TE=3200/97 ms) in transversal orientation were used for the monitoring of the punction of the prostate gland. Planning and control of the intervention is to be made outside the scanner room on a desktop computer that receives DICOM images from the scanner. Servopneumatic drives move the AMO to the insertion point. The physician has to introduce the punction needle manually. The mean deviation of the needle tip to the target in a gel phantom was 0.35 mm. An accurate punction of the prostate gland can easily be performed using this system with a transgluteal access. The T2-weighted images are superior for the evaluation of the prostate anatomy and the needle position during the interventions. In conclusion, our preliminary results indicate that this MR-guided assistance system is suitable for an accurate transgluteal needle placement in the prostate.

Automation↗

Preliminary experience with transarterial chemoembolization (TACE) in liver metastases of uveal malignant melanoma: local tumor control and survival.

PURPOSE: To evaluate results in the palliative treatment of patients with liver metastases of uveal malignant melanoma using transarterial chemoembolization (TACE). MATERIALS AND METHODS: Superselective TACE was repeatedly performed in 12 patients with liver metastases of uveal malignant melanoma. Six patients presented with solitary liver metastases (6-12 cm in size) and six patients with oligonodular metastases (n < or = 6). The embolization suspension consisted of a maximum of 10 mg/m(2) Mitomycin C, 10 ml Lipiodol, and an injection of 200-450 mg resorbable microspheres for vascular occlusion. In the follow-up, magnetic resonance imaging was performed in 3-month intervals. RESULTS: The TACE procedure was well tolerated in all patients without any relevant side effects. Three patients responded to TACE with a size reduction of more than 50% (partial response), five patients with stable disease, and four patients with progressive disease with an increase in volume of more than 25%. Mean survival following primary tumor treatment was 32.9 months, and after first embolization 19.5 months. Lower survival rates were recorded for the progressive group (16.5 months). CONCLUSION: Repeated TACE offers a palliative treatment option in patients with oligonodular liver metastases of uveal malignant melanoma.

Adult↗

Large-sized hepatocellular carcinoma (HCC): a neoadjuvant treatment protocol with repetitive transarterial chemoembolization (TACE) before percutaneous MR-guided laser-induced thermotherapy (LITT).

This study aims to evaluate the efficacy and safety of a neoadjuvant treatment protocol with repeated transarterial chemoembolization (TACE) before MR-guided laser-induced thermotherapy (LITT) for large-sized hepatocellular carcinomas (HCC). Repeated TACE (mean, 3.5 treatments per patient) was performed in 48 patients with neoadjuvant intention (the largest lesion was between 50 and 80 mm in diameter, and there were no more than five lesions). For the TACE treatment, we used 10 mg/m(2) mitomycin, 10 ml/m(2) Lipiodol and microspheres. The tumor volume was measured by MRI. Lipiodol retention of the tumors was evaluated with CT. After the diameter of the tumors had decreased to less than 50 mm, the patients were treated with MR-guided LITT 4 to 6 weeks after embolization. Repeated TACE reduced the tumor size in 32 patients (66.7%), forming the basis for performing MR-guided LITT procedures. These patients received one to four laser treatments (mean, 1.9 per patient) for tumor ablation, resulting in a median survival of 36.0 months after the first treatment. For the remaining patients, no reduction in tumor size was achieved in 12 patients and disease progression in 4 patients. Neoadjuvant TACE appears to be an effective treatment of large-sized HCC, which extends the indication for MR-guided LITT.

Aged↗

Staging of Klatskin tumours (hilar cholangiocarcinomas): comparison of MR cholangiography, MR imaging, and endoscopic retrograde cholangiography.

The aim of the study was to compare prospectively magnetic resonance cholangiography (MRC) and magnetic resonance imaging (MRI) with endoscopic retrograde cholangiography (ERC) in the diagnosis and staging of Klatskin tumours of the biliary tree (hilar cholangiocarcinomas). Forty-six patients with suspected Klatskin tumours of the biliary tract underwent MRI and heavily T2-weighted, non-breathhold, respiratory-triggered fast spin-echo MRC. Forty-two patients underwent ERC within 24 h; in four patients, ERC was not feasible, and percutaneous trans-hepatic cholangiography (PTC) was carried out instead. Two independent investigators evaluated imaging results for the presence of tumour, bile duct dilatation, and stenosis. Clinical and histopathological correlation revealed Klatskin tumours in 33 patients. MRI revealed a slightly hyperintense signal of infiltrated bile ducts in T2-weighted fast spin-echo sequences. The malignant lesion was regularly visualized as a hypointense area in T1-weighted gradient-echo sequences with substantial contrast enhancement along the involved bile duct walls. MRC revealed the location and extension of the tumour in 31 of 33 cases correctly (sensitivity 94%, specificity 100%, diagnostic accuracy 95%). In 27 of 31 cases, ERC enabled accurate staging and diagnosis of Klatskin tumours with a sensitivity of 87%. ERC and PTC combined yielded a sensitivity of 84% and a specificity of 97%. Tumours were grouped according to the Bismuth classification, with MRC allowing correct identification of type I tumour in seven patients, type II tumour in four patients, type III tumour in 12 patients, and type IV tumour in ten patients. MRC provided superior visualization of completely obstructed peripheral systems. MRC in combination with MRI is a reliable non-invasive diagnostic method for the pre-therapeutic staging of Klatskin tumours.

Adult↗

Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool.

The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04+/-43.17 s for the automatic approach and 526.88+/-45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion.

Aged↗

Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality.

PURPOSE: To prospectively evaluate to what extent image quality in 16-detector row computed tomographic (CT) coronary angiography is a function of the heart rate and the image reconstruction technique used. MATERIALS AND METHODS: A total of 70 patients (49 men, 21 women; mean age, 59.1 years +/- 5.8 [standard deviation]) consecutively underwent multi-detector row CT coronary angiography; 49 patients additionally underwent coronary angiography. Image reconstruction was based on both relative and absolute timing. A total of 20 equidistant relative and absolute image reconstructed intervals were assessed by applying a four-step grading scale. Cluster and discrimination analysis, Spearman correlation analysis, and Wilcoxon and chi2 tests were used for statistical analysis. Institutional review board approval and written informed consent were obtained. RESULTS: Though significantly (P < .001) better image quality was observed for image reconstruction based on absolute timing and in patients with lower heart rates, influence on diagnostic accuracy was not significant. Irrespective of the reconstruction technique used, best image quality was observed in patients with a low heart rate for middiastolic reconstruction intervals (starting points: 61% of R-R interval [range, 40%-75%] and 599.3 msec after R [range, 450-840 msec]) and in patients with a high heart rate for end-systolic or early-diastolic intervals (starting points: 27.3% of R-R interval [range, 10%-45%] and 202.3 msec after R [range, 82-336 msec]). With regard to the vessel section and reconstruction technique, cutoff heart rates of the intervals were 64.0-68.5 beats per minute. Patients with stenoses of more than 50% were identified with 86% sensitivity and specificity, and there was no significant difference between relative and absolute timing (P = .99). CONCLUSION: In multi-detector row CT coronary angiography, image quality depends on the choice of a suited reconstruction interval. In patients with high heart rates, the best image quality can be obtained with end-systolic and early-diastolic intervals; in patients with low heart rates, the best results are achieved with middiastolic intervals.

Adult↗

Peripheral artery stent visualization and in-stent stenosis analysis in 16-row computed tomography: an in-vitro evaluation.

The accuracy of 16-row multidetector CT in the visualization of different peripheral artery stents and in the appraisal of in-stent stenosis was assessed. Nine different stent types (nitinol and stainless steel) with three diameters (6, 8 and 10 mm) were used; altogether 27 stents were analyzed in a barrel-shaped vascular model. Low-grade (<40%) and high-grade (>60%) in-stent stenoses were simulated by polyurethane sticks (70 HU) of differing diameters (2-6 mm). Imaging was performed with 16x0.75-mm detector collimation, 130 mAs, 120 kV, 12-mm table feed/rotation, 1.0-mm slice thickness and 0.5-mm increment. The stent diameter, strut thickness, in-stent attenuation values, degree and degree of in-stent stenosis were evaluated. Nitinol stents showed significantly (P<10-6) less stent lumen narrowing, artificial strut thickening and overestimation of the degree of in-stent stenoses than stainless steel stents. In-stent attenuation values and artificial strut thickening were significantly (P<10-6) lower in 10- and 8-mm stents than in 6-mm stents. Stent lumen narrowing was significantly less in 10-mm stents than in 8-mm (P<10-4) or 6-mm (P<10-6) stents. In-stent stenoses were significantly overestimated, irrespective of the stent diameter. In 6-mm stents overestimation was significantly higher than in 8-mm (P<0.01) or 10-mm stents (P<10-6). Under in-vitro conditions 16-row MDCT allowed an accurate identification of in-stent stenosis, but significantly overestimated the effective degree of the stenosis.

Constriction, Pathologic↗

Percutaneous interventional reconstruction of the iliac arteries: primary and long-term success rate in selected TASC C and D lesions.

We report the primary and long-term outcome of patients with selected TransAtlantic Inter-Society Consensus (TASC) C or D lesions of the iliac arteries after percutaneous interventional reconstruction. Between 1999 and 2001, 89 patients with peripheral arterial disease categorized as TASC C (n=37) and D (n=52) underwent percutaneous interventional reconstruction and stent implantation. Patients were followed for 1-62 months (mean 36 months). Patency rates were assessed by Duplex ultrasound and ankle-brachial index (ABI) measurement. The primary technical success rate was 96.9% with an overall complication rate of 5.6%. The ABI improved from an average of 0.51+/-0.15 before intervention to 0.79+/-0.16 on the day following intervention and to 0.81+/-0.17 within 3 years after intervention. Clinical improvement was observed in 97.3% of the patients in the TASC C group and in 88.5% in the TASC D group. Eighty of 89 patients (89.9%) remained patent at 3-year follow-up. In five patients the reintervention was successful. The secondary patency rate was 95.5%. The patency rates were similar in our selected TASC C and D patients to those so far published for TASC A and B, with low complication rates. Therefore, percutaneous intervention can be recommended for these patients.

Angioplasty, Balloon↗

Decreased intermediate term patency of automated proximal anastomoses evaluated by sequential ultrafast CT.

OBJECTIVE: The Symmetrytrade mark aortic connector creates proximal anastomoses of saphenous vein grafts using a nitinol implant. The device avoids partial clamping and thus possibly reduces neurologic complications. To evaluate graft patency, a single surgeon randomised study was performed in our institution. METHODS: Seventy-seven patients were randomised either to automated proximal anastomoses (group I, n=39, 61 vein grafts connected using the aortic connector, 47 as single, 15 as sequential bypasses) or controls (group II, n=38, 62 proximal anastomoses handsewn, 46 as single, 16 as sequential bypasses). Ultrafast CT-scans were performed on postoperative day 5 in 34 patients of group I and 16 patients of group II to evaluate early graft patency. Intermediate term patency was evaluated with ultrafast CT-scan in 30 patients of group I (46 grafts) and 25 patients of group II (39 grafts) 1 year after the operation. RESULTS: Two early graft occlusions were detected in group I (3.8%). In group II all evaluated grafts were patent 5 days after surgery. 11.4 months after surgery, seven out of 46 grafts were found occluded (15.2%) in group I. In the control group, only one occlusion was detected (2.6%). CONCLUSIONS: We observed a trend towards an increased occlusion rate 1 year after surgery with automated connector devices. For evaluation of long-term patency larger patient groups have to be evaluated. Other benefits of these devices have to be proven to promote their clinical application.

Adult↗

Flat-panel detector computed tomography for the assessment of coronary artery stents: phantom study in comparison with 16-slice spiral computed tomography.

PURPOSE: The evaluation of coronary artery stents is a major limitation of cardiac multislice spiral computed tomography (MSCT). The development of flat-panel detector computed tomography (FPCT) with truly isotropic spatial resolution may overcome this limitation. Thus, we evaluated the use of FPCT in comparison to MSCT for the assessment of coronary artery stents. MATERIAL AND METHODS: Eight different coronary artery stents with a diameter of 3 mm each were placed in a static chest phantom. The phantom was positioned in the CT gantry at angles of 0 degrees , 45 degrees , and 90 degrees toward the z-axis and examined with the prototype of a FPCT (Siemens, Forchheim, Germany) and a commercially available 16-detector row MSCT (Sensation 16, Siemens). Slice thickness was 0.25 mm with FPCT whereas for MSCT, an effective slice thickness of 1 mm with a reconstruction increment of 0.5 mm was used. Image quality was assessed visually using a 5-point grading scale. Stent diameters were measured and compared using a repeated-measures analysis of variance. RESULTS: When compared with MSCT, artificial lumen reduction was significantly less using FPCT. On average the visible stent lumen was reduced by 16.1% with FPCT, whereas the mean of the lumen reduction was 47.2% with 16-detector row MSCT. Visible lumen diameter as well as image noise significantly increased using FPCT (P < 0.001). With FPCT delineation of the different stent struts became possible. CONCLUSION: FPCT proved to be superior when compared with 16-detector row MSCT for the in vitro assessment of coronary artery stents. Improved spatial resolution allows for a detailed assessment of the coronary artery stent lumen.

Coronary Angiography↗

MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation.

The purpose of this study was to investigate the proximal anastomosis of CABG grafts created by a nitinol aortic connector. After receiving CABG, 33 patients underwent CT examination of the heart. On the same patients, CT was performed on postoperative day 5 (4-row CT, group A) and again 1 year thereafter (16-row CT, group B). Twenty-three ACVB to RCX and 27 ACVB to RCA grafts were included. Every anastomosis was reviewed under different reformations (MIP, MPR and VRT). Interobserver correlation was determined. Five days postoperatively, 48/50 anastomoses were classified as patent. One year postoperatively, 42/50 anastomoses were classified as patent. In both groups, the aortic connector could be visualized with good quality: 1.82+/-1.10 (group A) and 1.93+/-1.22 (group B) for ACVB to RCA, similar results for ACVB to RCX grafts (MPR). Image quality at the aortic connector site did not display a significant difference for any reformation between groups (P>0.05). Within groups, MPR displayed better visualization than MIP and VRT (P<0.05). In the presence of metal implants, CT provides reliable data in evaluation of the proximal anastomosis. Sixteen-row CT does not bring a significant benefit to image quality. MPR displayed the best visualization within both groups.

Aged↗

Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography.

UNLABELLED: The purpose of this study was to investigate the image quality of coronary artery bypass graft visualization in 4- and 16-row multidetector CT using multiple imaging reformations. MATERIAL AND METHODS: One hundred sixteen patients underwent CT examination of the heart after receiving CABG. Group A (n=58) received 4-row MDCT; group B (n=58) received 16-row MDCT. Various bypass types such as LITA to LAD and venous grafts to the RCA and RCX were included in the study. A five-point Likert scale was used to grade image quality. Each bypass was reviewed under different imaging reformations: thin slap maximum intensity projection (MIP thin), multiplanar reformation (MPR) and volume rendering technique (VRT). Special attention was paid to the delineation of the distal anastomosis. Interobserver correlation was determined. RESULTS: From 289 bypass grafts examined, 279 (96.54%) were classified as patent and 10 (3.46%) as not patent. Except for the distal anastomosis, 16-row MDCT showed significantly better results for all segments of bypasses. Comparison of reformations within group A and B showed that MIP thin (P<0.05) and VRT (P<0.05) displayed better visualization as compared to MPR. CONCLUSION: Significantly better imaging of all bypass types is possible using 16-row MDCT as compared to 4-row MDCT. Assessment of the distal anastomosis yields no difference between 4- and 16-row technology.

Adult↗

Extracorporeal shock wave therapy in calcific tendinitis of the shoulder.

OBJECTIVE: To investigate clinical (pain, mobility) and radiological (resolution of calcium deposits) efficacy of different energy levels of extracorporeal shock wave therapy (ESWT) in calcific tendinitis of the shoulder. DESIGN AND PATIENTS: There were 90 study subjects with radiographically verified calcific tendinitis of one shoulder, mean age 52+/-6 years (range 29-65 years; females:males=55:35), all of whom had had symptoms for at least 6 months and substantial restriction of shoulder mobility and pain that required taking anti-inflammatory drugs. Calcium deposits were of type I or type II (clearly circumscribed and dense) and ranged from 1 cm to 3 cm in diameter. Subjects were divided into three groups to receive ESWT at one of two energy levels (E1=0.15 mJ/mm2, E2=0.44 mJ/mm2) or sham treatment. Treatment was given at 6 weekly intervals until symptoms resolved, five treatments had been given or the subject dropped out of the programme. RESULTS: All subjects in groups E1 and E2 completed the programme. Those in group E1 had significantly less pain during treatment but more treatments than those in group E2, and at 6 month follow-up had residual calcification and recurrence of pain (87%). Subjects in group E2 had no residual calcification or recurrence of pain. Sham treatment had no effect. There were no side effects except a small number of haematomas (2 in E1, 6 in E2; maximum size 2 cm). CONCLUSION: ESWT in calcific tendinitis of the shoulder is very effective. It does not have significant side effects at an energy level of E=0.44 mJ/mm2, which can therefore be recommended.

Adult↗

MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results.

The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions.

Aged↗

Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner.

The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6+/-1.4) who had been admitted for coronary artery bypass graft surgery underwent CT examination of the thorax (Sensation 16, Siemens, Inc., Forchheim, Germany). All patients were examined with 16x0.75-mm collimation. Image reconstruction was performed for two groups. In group A ( n=32), slice thickness of 1.5 mm and an overlap of 0.75 mm were used. In group B ( n=32), slice thickness of 0.75 mm and an overlap of 0.4 mm were applied. Retrospective ECG triggering was performed in all patients. The maximum order of recognizable bronchi was determined in each data set. In addition to assessing the maximum order of bronchial bifurcation, bronchial diameter was determined in truly perpendicular sections in each patient. For every segment proximal to a bifurcation, image quality was subjectively graded as poor (grade 1), moderate (grade 2) or good (grade 3). The observers were asked to identify the minimum cardiac movement ECG-triggered image sets assuming that they would be of better quality than the maximum cardiac movement ECG-triggered image sets. The Mann-Whitney U-test and the Fisher's Exact Test were used for statistical evaluation. In group A, a mean of 4.8+/-0.2 bifurcations was ascertained vs. 6.5+/-0.3 bifurcations in group B [ P<0.0003]. For bronchial diameters in group A, a mean of 7.5+/-0.4 mm was determined vs. 4.6+/-0.4 mm in group B [ P<0.0001]. In group B, two independent radiologists observed a significant shift to better image quality in all segments evaluated [ P<0.006 to P<0.000001]. Motion artifacts were judged as being significantly reduced by minimum cardiac movement ECG-triggering in group B [observer 1: P=0.0007 (20/32); observer 2: P=0.008 (18/32)], but not in group A [observer 1: P=0.286 (13/32); observer 2: P=0.123 (16/32)]. Sub-millimeter collimation and minimum cardiac movement ECG-triggered data acquisition allow deeper penetration into the tracheo-bronchial system allowing visualization of the bronchial surface down to diameters below 5 mm in certain cases up to the eighth bifurcation. Along with an enhanced visualization as such, better image quality is acquired in all segments evaluated. Trade off between better image quality, of doubtful diagnostic consequence, and much higher irradiation dose must be made.

Aged↗

Interstitial photodynamic laser therapy in interventional oncology.

Photodynamic therapy (PDT) is a well-investigated locoregional cancer treatment in which a systemically administered photosensitizer is activated locally by illuminating the diseased tissue with light of a suitable wavelength. PDT offers various treatment strategies in oncology, especially palliative ones. This article focuses on the development and evaluation of interstitial PDT for the treatment of solid tumors, particularly liver tumors. The PDT is mostly used for superficial and endoluminal lesions like skin or bladder malignancies and also more frequently applied for the treatment of lung, esophageal, and head and neck cancer. With the help of specially designed application systems, PDT is now becoming a practicable option for solid lesions, including those in parenchymal organs such as the liver. After intravenous treatment with the photosensitizer followed by interstitial light activation, contrast-enhanced computed tomography shows the development of therapy-induced necrosis around the light-guiding device. With the use of multiple devices, ablation of liver tumors seems to be possible, and no severe side effects or toxicities related to the treatment are reported. PDT can become a clinically relevant adjunct in the locoregional therapy strategies.

Humans↗

Successful treatment of deep sternal infections following open heart surgery by bilateral pectoralis major flaps.

OBJECTIVES: Severe sternum necrosis requiring extended resection necessitates plastic reconstruction of the resulting defect and stabilization of the chest. We analyzed the outcome of patients undergoing bilateral pectoralis major flap repair on functional and cosmetic results, chest stabilization and pulmonary function. METHODS: Twelve patients undergoing cardiac surgery between 1997 and 2001 suffered from a deep mediastinal wound infection and sternum necrosis. After a mean of two attempts of extensive wound debridement, all 12 patients underwent complete sternal resection with plastic reconstruction by bilateral pectoralis major flaps. Risk factors were obesity (n=10) and diabetes (n=11). Six months postoperatively patients underwent physical examination, pulmonary function testing and functional CT scan. RESULTS: Three patients died in hospital (two septic multiorgan failure, one heart failure) and nine were discharged with complete wound closure. One patient suffered a lethal stroke during follow-up. At 6-month follow-up no recurrent sternum infection had occurred. Chest stability was satisfactory without impairment of pulmonary function (VC 77.5+/-12.1% at follow-up vs 77.8+/-12.5% preoperatively). Mobility and force of arms and shoulder were adequate; at CT scan the maximum distance change between the former sternoclavicular joint in inspiration versus expiration was minimal. Quality of life questionnaires showed no significant limitations except a disturbed sleep and mild restriction of executing hobbies and social activities. CONCLUSIONS: Bilateral pectoralis major flap repair is a safe technique to cure severe mediastinitis necessitating complete sternal resection. Wounds close without extensive reconstructive surgery. Cosmetic results as well as stabilization of the chest were good. Patients reported an almost uncompromised quality of life without respiratory impairment.

Aged↗