Publications and source records attributed to Christopher J Easley.

8 recordsLinked to original sources

A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability.

We describe a microfluidic genetic analysis system that represents a previously undescribed integrated microfluidic device capable of accepting whole blood as a crude biological sample with the endpoint generation of a genetic profile. Upon loading the sample, the glass microfluidic genetic analysis system device carries out on-chip DNA purification and PCR-based amplification, followed by separation and detection in a manner that allows for microliter samples to be screened for infectious pathogens with sample-in-answer-out results in < 30 min. A single syringe pump delivers sample/reagents to the chip for nucleic acid purification from a biological sample. Elastomeric membrane valving isolates each distinct functional region of the device and, together with resistive flow, directs purified DNA and PCR reagents from the extraction domain into a 550-nl chamber for rapid target sequence PCR amplification. Repeated pressure-based injections of nanoliter aliquots of amplicon (along with the DNA sizing standard) allow electrophoretic separation and detection to provide DNA fragment size information. The presence of Bacillus anthracis (anthrax) in 750 nl of whole blood from living asymptomatic infected mice and of Bordetella pertussis in 1 microl of nasal aspirate from a patient suspected of having whooping cough are confirmed by the resultant genetic profile.

DNA↗

Chitosan as a polymer for pH-induced DNA capture in a totally aqueous system.

A novel DNA solid-phase extraction protocol based on the pH-dependent charge of chitosan was developed specifically for low-volume DNA extraction on microchips. The method uses chitosan-coated beads to extract DNA at pH 5 and release it from the chitosan at pH 9. DNA extraction efficiency as high as 92% could be attained, even from complex samples such as human blood containing significant amounts of protein. Using this method, PCR inhibitors that are typically used in DNA extraction procedures (e.g., chaotropic salts, 2-propanol) can be avoided, making the method more conducive to downstream sample processing using PCR. A high-density multichannel microchip device was then fabricated and the microchannels coated with chitosan for DNA extraction in an open channel configuration without the need for an additional stationary phase. This design provided a relatively high surface area-to-volume ratio for extraction, while retaining the low flow resistance commensurate with open channels. With a flow rate of approximately 1 microL/min during the extraction, the total extraction time was less than 10 min, with most of the DNA recovered in the first 2 microL of elution buffer. Using the microchip device, extraction efficiencies for lambda-phage DNA and human genomic DNA were as high as 67 and 63%, respectively. Human genomic DNA from whole blood samples could be extracted in 10 min with an extraction efficiency of 75 +/- 4% (n = 3), and the purified DNA was suitable for PCR amplification of a fragment of the gelsolin gene. The combination of an entirely aqueous DNA extraction method with a high-density, low-flow resistance microchannel pattern sets the stage for future integration into microfluidic genomic analysis devices.

Chitosan↗

On-chip pressure injection for integration of infrared-mediated DNA amplification with electrophoretic separation.

Poly(dimethylsiloxane) (PDMS) membrane valves were utilized for diaphragm pumping on a PDMS-glass hybrid microdevice in order to couple infrared-mediated DNA amplification with electrophoretic separation of the products in a single device. Specific amplification products created during non-contact, infrared (IR) mediated polymerase chain reaction (PCR) were injected via chip-based diaphragm pumping into an electrophoretic separation channel. Channel dimensions were designed for injection plug shaping via preferential flow paths, which aided in minimizing the plug widths. Unbiased injection of sample could be achieved in as little as 190 ms, decreasing the time required with electrokinetic injection by two orders of magnitude. Additionally, sample stacking was promoted using laminar or biased-laminar loading to co-inject either water or low ionic strength DNA marker solution along with the PCR-amplified sample. Complete baseline resolution (Res = 2.11) of the 80- and 102-bp fragments of pUC-18 DNA marker solution was achieved, with partially resolved 257- and 267-bp fragments (Res = 0.56), in a separation channel having an effective length of only 3.0 cm. This resolution was deemed adequate for many PCR amplicon separations, with the added advantage of short separation time-typically complete in <120 s. Decreasing the amount of glass surrounding the PCR chamber reduced the DNA amplification time, yielding a further enhancement in analysis speed, with heating and cooling rates as high as 13.4 and -6.4 degrees C s(-1), respectively. With the time requirements greatly reduced for each step, it was possible to seamlessly couple IR-mediated amplification, sample injection, and separation/detection of a 278-bp fragment from the invA gene of <1000 starting copies of Salmonella typhimurium DNA in approximately 12 min on a single device, representing the fastest PCR-ME integration achieved to date.

DNA Replication↗

Rapid DNA amplification in glass microdevices.

The polymerase chain reaction (PCR) for amplification of DNA has become a very useful tool in scientific research and analytical laboratories, yet conventional techniques are time-consuming, and the reagents are expensive. Miniaturization of this technique has the potential to drastically reduce amplification time and reagent consumption while simultaneously improving the efficiency of the reaction. Increasing the surface area-to-volume ratio using microfluidic reaction chambers allows homogeneous solution temperatures to be achieved much more rapidly than in conventional heating blocks. Employing infrared radiation to selectively heat the reaction solution can additionally reduce the time and energy needed for thermocycling; the reaction container is not heated and can even serve as a heat sink for enhancement of cooling. Microchip systems also provide the potential for fabrication of structures for additional processing steps directly in line with the PCR chamber. Not only can amplification be integrated with product separation and analysis, but sample preparation steps can also be incorporated prior to amplification. The ultimate goal is a miniature total-analysis-system with seamlessly coupled sample-in/answer-out capabilities that consumes very low volumes of reagents and drastically reduces the time for analysis. This chapter will focus on the materials and methods involved in simple straight-channel microchip PCR on glass substrates using non-contact thermocycling.

Bacterial Proteins↗

Glass microfluidic devices with thin membrane voltage junctions for electrospray mass spectrometry.

In this study a novel glass membrane was prepared for conducting high voltage (HV) to solution in the channel of a microfabricated device for generation of liquid electrospray. Taylor cone formation and mass spectra obtained from this microdevice confirmed the utility of the glass membrane, but voltage conduction through the membrane could not be successfully explained based solely on the conductivity of the glass itself. This novel method for developing a high-voltage interface for microdevices avoids direct metal/liquid contact eliminating bubble formation in the channel due to water hydrolysis on the surface of the metal. Further, this arrangement produces no dead volume as is often found with traditional liquid junctions. At the same time, preliminary investigations into the outlet design of glass microdevices for interfacing with electrospray mass spectrometry, was explored. Both the exit shape and the use of hydrophobic coatings at the channel exit of the microdevice electrospray interface were evaluated using standard proteins with results indicating the utility of this type of design after further optimization.

Equipment Design↗

Extrinsic Fabry-Perot interferometry for noncontact temperature control of nanoliter-volume enzymatic reactions in glass microchips.

Optical fiber extrinsic Fabry-Perot interferometry (EFPI) was investigated as a noncontact temperature sensor and utilized for regulating the temperature of small-volume solutions in microchips. Interference pattern analysis determined the optical path lengths (OPL) associated with reflections from various surfaces on or in the microchip, in particular, from gold sputtered on the bottom of a microchannel. Since OPL is directly proportional to refractive index, which is dependent on solution temperature, the EFPI sensor was capable of noncontact monitoring of solution temperature simply from alterations in the measured path length. Calibration of the sensor against a thermocouple was performed while heating the microchip in a noncontact manner with an IR lamp. The combination of EFPI temperature sensor, IR-mediated heating, and air cooling allowed a fully noncontact system for small-volume temperature control in microchip structures, and its utility was illustrated by optimal digestion of DNA by a temperature-dependent restriction endonuclease in 320 nL. The functionality and simplicity of the microchip EFPI temperature sensor was enhanced by replacing the prebonding sputtered gold with a tunable, chemically plated semireflective silver coating created in situ after chip fabrication. This provided an 8-fold improvement in the lowest detectable temperature change (deltaT = 0.1 degrees C), facilitated primarily by enhanced reflection from both the bottom and top surfaces of the microchannel. This approach for controlling micro- and nanoscale reactions--with heating, cooling, and temperature control being carried out in a completely noncontact fashion--provides an accurate and sensitive method for executing chemical and biochemical reactions in microchips.

Biosensing Techniques↗

Capillary electrophoresis with laser-induced fluorescence detection for laboratory diagnosis of galactosemia.

Galactosemia, a metabolic disorder associated with the intolerance to dietary galactose due to an inherited enzymatic deficiency, is indicated by heightened levels of galactose in urine (galactosuria). In this report, capillary electrophoresis (CE) with laser-induced fluorescence detection was evaluated for its ability to screen urinary carbohydrates, particularly galactose. Neonatal urine samples with normal and abnormal levels of galactose were analyzed with galactose concentrations quantitated relative to urinary creatinine concentrations to account for variable urinary dilution. Analysis of nine samples by CE in a single-blind manner defined four as negative (normal) and five as positive for galactosuria with galactose levels as high as 146.8 +/- 5.9 mM. Galactosuria was correlated with clinical galactosemia diagnoses for four of the positive samples, while the remaining positive was associated with a patient diagnosed with Hurler's syndrome.

Electrophoresis, Capillary↗