Christopher Kai-shun Leung

Publications and source records attributed to Christopher Kai-shun Leung.

6 recordsLinked to original sources

Alignment artifacts in optical coherence tomography analyzed images.

PURPOSE: To compare retinal thickness and retinal height of the original scanned optical coherence tomography (OCT) images with those of the same images after automated retinal thickness analysis. DESIGN: Cross-sectional study. PARTICIPANTS: Thirty normal eyes, 20 eyes with neovascular age-related macular degeneration (AMD), 20 with central serous chorioretinopathy (CSC), 20 with macular holes, and 20 with non-AMD related macular edema from 110 subjects were selected randomly from an OCT database. One of the 6 macular scans in each eye was chosen randomly for analysis. METHODS: Two sets of OCT images--original images and analyzed images (after retinal thickness [single eye] analysis)--in each eye were exported for retinal thickness or retinal height measurement. Comparisons of retinal thickness or retinal height at selected locations were performed. MAIN OUTCOME MEASURES: Retinal thickness (defined as the distance between the anterior boundary of the retinal nerve fiber layer [RNFL] and posterior boundary of the photoreceptor layer) and retinal height (defined as the distance between the anterior boundary of the RNFL and baseline level of the anterior boundary of the retinal pigment epithelium [RPE]). Retinal height was measured when there was detachment of neurosensory retina or RPE. RESULTS: No significant difference in retinal thickness was observed between the original and the analyzed OCT images in normal eyes and in eyes with macular holes or non-AMD related macular edema. However, OCT-analyzed images demonstrated retinal thickness or retinal height measurements in eyes with CSC or neovascular AMD significantly lower than the corresponding measurements in the original images (all with Ps< or =0.001, Wilcoxon signed rank test). In the groups of neovascular AMD and CSC, Bland-Altman plots revealed mean differences of 124 mum (95% limits of agreement between -65.5 and 313.6) and 84.4 mum (95% limits of agreement between -178.0 and 346.8), respectively, between the original and analyzed retinal measurements. CONCLUSIONS: Retinal thickness and retinal height could be underestimated in patients with CSC or neovascular AMD after retinal thickness analysis in Stratus OCT when either automatic measurements or manual caliper-assisted measurements are performed on the analyzed images. We recommend exporting the original scanned OCT images for retinal thickness and retinal height measurement in patients with CSC or neovascular AMD.

Aged↗

Analysis of bleb morphology after trabeculectomy with Visante anterior segment optical coherence tomography.

BACKGROUND: To describe the use of anterior segment optical coherence tomography (OCT) in imaging intrableb morphology after trabeculectomy. METHODS: 14 post-trabeculectomy eyes from 11 primary open angle glaucoma and 3 primary angle closure glaucoma subjects were studied. The blebs were classified with reference to slit lamp morphology and bleb function. They included diffuse filtering (n = 7), cystic (n = 2), encapsulated (n = 2) and flattened (n = 3) bleb types. One eye in each patient was imaged with the Visante anterior segment OCT. A vertical scan line of 10 mm consisting of 512 A-scans was positioned at the centre of the bleb. The images were then analysed by built-in software. Intrableb morphologies and structures, including bleb wall thickness, subconjunctival fluid collections, suprascleral fluid space, scleral flap thickness, intrableb intensity (low, medium or high) and the route under the scleral flap were characterised and measured. RESULTS: Diffuse filtering blebs were found by subconjunctival fluid collections. Suprascleral fluid space and the route under the scleral flap were identified in four of the seven cases. Cystic blebs were composed of a large hyporeflective space with multiloculated fluid collections covered by a thin layer of conjunctiva. Encapsulated blebs had a thick bleb wall with high reflectivity and an enclosed fluid filled space. Flattened blebs demonstrated high scleral reflectivity and no bleb elevation. CONCLUSIONS: Visante anterior segment OCT can be used for bleb imaging. The different patterns of intrableb morphology identified by OCT were related to slit lamp appearance and bleb function. This information may be useful to study the different surgical outcomes and the process of wound healing in trabeculectomised eyes.

Adult↗

Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA).

OBJECTIVE: To describe a novel approach to measuring anterior chamber angle dimensions and configurations. METHODS: Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 (white), and the edge points outlining the angle were detected and fitted with straight lines. The dimensions and profiles of anterior chamber angles were then measured. RESULTS: The algorithm failed to identify the edge points correctly in 8 (11.6%) of 69 images because of strong background noise. Three basic types of angle configuration were identified based on the derived angle profiles: constant, increasing, and decreasing, which corresponded to flat, bowed forward, and bowed backward iris contours, respectively. The angle measurements demonstrated high correlation with trabecular-iris angle and angle opening distance 500 (calculated as the distance from the corneal endothelium to the anterior iris surface perpendicular to a line drawn at 500 mum from the scleral spur). The strongest association was found between the averaged angle derived from the angle profile and the angle opening distance 500 (r = 0.91). CONCLUSION: The proposed algorithm has high correlations with angle opening distance and trabecular-iris angle with the added advantages of being fully automated, reproducible, and able to capture the characteristic angle configurations. However, good-quality ultrasound biomicroscopic images with high signal-to-noise ratio are required to identify the edge points correctly.

Algorithms↗

Analysis of retinal nerve fiber layer and optic nerve head in glaucoma with different reference plane offsets, using optical coherence tomography.

PURPOSE: To evaluate the performance of retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters analyzed with different offsets of reference plane in detecting early glaucomatous changes and in correlation with visual function using optical coherence tomography (OCT). METHODS: This was a cross-sectional study consisting of 41 normal subjects and 30 with early and 40 with advanced glaucoma. RNFL thickness and ONH parameters were measured with reference planes positioned at 95, 150, and 205 microm above the level of retinal pigment epithelium (RPE). Discriminating power for early glaucoma detection and correlation with visual field MD for each parameter at different levels of reference plane were compared by using the analyses of area under the receiver operating characteristic curves (AUCs) and linear regression, respectively. RESULTS: All ONH measurements were significantly different between normal and glaucoma groups, irrespective of the level of reference plane. In normal eyes, changing the reference plane position resulted in significant differences in ONH measurements. Among all the parameters examined, integrated rim volume and RNFL thickness measured at 150 microm above the RPE showed the largest AUC (0.966) for early glaucoma detection, and the strongest correlation with visual function (r = 0.793), respectively. CONCLUSIONS: OCT analysis of the ONH and RNFL is useful for early glaucoma detection. Among the three reference planes examined in this study, measurements analyzed at 150 microm above the RPE demonstrated the best performance for glaucoma detection and correlation with visual function. Compared with ONH measurements, RNFL thickness may be a better indicator, reflecting retinal ganglion cell function and monitoring disease progression.

Cross-Sectional Studies↗

Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx VCC, I: correlation analysis in glaucoma.

PURPOSE: To evaluate the average and regional correlations of retinal nerve fiber layer (RNFL) thickness measured by StratusOCT (optical coherence tomography; Carl Zeiss Meditec, Inc., Dublin, CA) and GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA). METHODS: Eighty-nine subjects-27 normal, 21 with suspected glaucoma, and 41 with glaucoma-were included in this cross-sectional study. The total average and the mean 12-clock-hour RNFL thickness were measured with the StratusOCT and GDx VCC. The discriminating powers of the two techniques for detection of suspected glaucoma and glaucoma were compared by the area under the receiver operating characteristic curves (AUC). Correspondence between StratusOCT and GDx VCC RNFL measurements in each clock hour was examined with linear regression analysis. RESULTS: The average RNFL thickness in the normal group was measured at 101.38 +/- 7.73 and 55.26 +/- 4.32 mum by StratusOCT and GDx VCC, respectively. Both nerve fiber analyzers demonstrated a double-hump pattern in the RNFL profiles with maximum RNFL thickness located at the inferotemporal and superotemporal clock hours by the StratusOCT and the superior and inferior clock hours by the GDx VCC. Significant differences were found in the total average and the individual clock-hour RNFL thickness between StratusOCT and GDx VCC RNFL measurements in both the normal and the suspected glaucoma/glaucoma groups. The GDx VCC superior RNFL measurement demonstrated the largest AUC (0.909) for detection of suspected glaucoma and glaucoma, whereas the largest AUC (0.901) in StratusOCT was found over the inferotemporal clock hour. The total average RNFL thickness measured with StratusOCT and GDx VCC correlated highly with each other (r = 0.852). When the respective clock-hour RNFL measurements were compared, the correlation coefficient varied with the position around the optic nerve head, with the highest correlation found over the superior and inferior clock hours (11, 12, 1, 6, and 7 o'clock; all with r > 0.700) and the lowest located at the temporal clock hour (9 o'clock; r = 0.277). CONCLUSIONS: Despite the substantial differences in the values of RNFL thickness, significant correlations were observed between StratusOCT and GDx VCC RNFL measurements. The variations of the correlation coefficient around the optic nerve head suggested that GDx VCC RNFL measurement does not have a fixed relationship with that of StratusOCT and the use of site-specific RNFL birefringences may improve the estimation of RNFL thickness by the GDx VCC. Nevertheless, the GDx VCC was found to be as effective as the StratusOCT in detecting the loss of RNFL in glaucoma.

Birefringence↗

Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx VCC, II: structure/function regression analysis in glaucoma.

PURPOSE: To evaluate the structure/function relationship between visual field sensitivity and retinal nerve fiber layer (RNFL) thickness measured by StratusOCT (Carl Zeiss Meditec, Inc., Dublin, CA) and GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA). METHODS: Eighty-nine subjects (27 who had healthy eyes, 21 who were glaucoma suspect, 41 who had glaucoma) were enrolled in this cross-sectional study. RNFL thickness was measured using the StratusOCT and the GDx VCC, and visual field (VF) was examined using the Humphrey VF analyzer. The relationship between RNFL thickness and VF sensitivity-expressed in terms of mean deviation (MD) in decibel (dB) scale, unlogged 1/lambert (L), and Advanced Glaucoma Intervention Study (AGIS) and Collaborative Initial Glaucoma Treatment Study (CIGTS) VF scores-were evaluated with linear and nonlinear regression models. Coefficient of determination (R(2)) was calculated, and regression models were compared using the Akaike information criterion and the F test. RESULTS: In plotting MD against RNFL thickness, curvilinear regression models demonstrated the best fit, whereas linear regression attained the best associations when VF sensitivity was expressed in 1/L. However, when healthy subjects were excluded from the analyses, the second-order polynomial was better than linear regression in describing the relation between 1/L and GDx VCC-measured RNFL thickness. Regression profiles between AGIS/CIGTS VF scores and RNFL thickness were best described in the linear and the first-order inverse models for GDx VCC and StratusOCT RNFL measurements, respectively. In general, StratusOCT RNFL measurements achieved higher associations with visual function in all the respective regression analyses than did GDx VCC. CONCLUSIONS: Description of structure/function relationships in glaucoma depends on the choice of perimetry scale, the type of RNFL measuring device, and the characteristics of the studied groups. The higher association with visual function in StratusOCT RNFL measurements compared with that in GDx VCC suggested optical coherence tomography might be a better approach for evaluating structure/function relationships. Curvilinear regression profiles found between StratusOCT RNFL thickness and MD/VF scores provide an explanation for those longitudinal observations, showing that VFs with higher AGIS/CIGTS VF scores or worse MD at baseline are at higher risk for deterioration. Regression analysis of the structure/function profile could provide important information in the assessment of the trend and pattern of glaucoma progression.

Disease Progression↗