PubMed Health⌕ Search

Biomedical subjects

Christopher M Rouleau

Publications and source records attributed to Christopher M Rouleau.

6 recordsLinked to original sources

Normal-incidence generalized ellipsometry using the two-modulator generalized ellipsometry microscope.

A new microscope is described that is capable of measuring the polarization characteristics of materials in normal-incidence reflection with a demonstrated lateral resolution of 4 microm. The instrument measures eight parameters of the sample Mueller matrix, which can be related to the diattenuation, retardation, circular diattenuation, direction of the principal axis, and the polarization factor. With proper calibration, the eight elements of the sample Mueller matrix can be determined to better than 0.001-0.002 for small values. Examples are given for aluminum, rutile (TiO2), and calcite (CaCO3).

Journal Article↗

Nonequilibrium interlayer transport in pulsed laser deposition.

We use time-resolved surface x-ray diffraction measurements with microsecond range resolution to study the growth kinetics of pulsed laser deposited . Time-dependent surface coverages corresponding to single laser shots were determined directly from crystal truncation rod intensity transients. Analysis of surface coverage evolution shows that extremely fast nonequilibrium interlayer transport, which occurs concurrently with the arrival of the laser plume, dominates the deposition process. A much smaller fraction of material, which is governed by the dwell time between successive laser shots, is transferred by slow, thermally driven interlayer transport processes.

Journal Article↗

Determination of optical birefringence by using off-axis transmission ellipsometry.

Utilizing transmission ellipsometry at small angles of incidence, it is shown that c-cut uniaxial samples can be used to determine both the miscut of the optic axis with respect to the plane of incidence as well as very accurate values of the spectroscopic birefringence. For example, wafers of ZnO, LiNbO3, and 6H-SiC single-crystals are examined and the miscut direction and the spectroscopic birefringence are determined. While all materials show strong dispersion in birefringence, ZnO exhibits a distinct isotropic point at 396.8 nm.

Journal Article↗

Strong polarization enhancement in asymmetric three-component ferroelectric superlattices.

Theoretical predictions--motivated by recent advances in epitaxial engineering--indicate a wealth of complex behaviour arising in superlattices of perovskite-type metal oxides. These include the enhancement of polarization by strain and the possibility of asymmetric properties in three-component superlattices. Here we fabricate superlattices consisting of barium titanate (BaTiO3), strontium titanate (SrTiO3) and calcium titanate (CaTiO3) with atomic-scale control by high-pressure pulsed laser deposition on conducting, atomically flat strontium ruthenate (SrRuO3) layers. The strain in BaTiO3 layers is fully maintained as long as the BaTiO3 thickness does not exceed the combined thicknesses of the CaTiO3 and SrTiO3 layers. By preserving full strain and combining heterointerfacial couplings, we find an overall 50% enhancement of the superlattice global polarization with respect to similarly grown pure BaTiO3, despite the fact that half the layers in the superlattice are nominally non-ferroelectric. We further show that even superlattices containing only single-unit-cell layers of BaTiO3 in a paraelectric matrix remain ferroelectric. Our data reveal that the specific interface structure and local asymmetries play an unexpected role in the polarization enhancement.

Journal Article↗

Transmission two-modulator generalized ellipsometry measurements.

The two-modulator generalized ellipsometer has been used to measure samples in transmission. In this configuration, the instrument can completely characterize a linear diattenuator and retarder, measuring birefringence, diattenuation, the angle of the principal axis, and the sample depolarization simultaneously and accurately. This instrument can be operated in two modes: (1) spectroscopic, in which measurements are made through the entire sample aperture as a function of wavelength, and (2) spatially resolved, in which measurements are made at a single wavelength and a birefringence picture is made of the sample. Current spatially resolved measurements have been made at a resolution of approximately 40 microm. Four samples have been examined with this instrument: (1) a mica plate, (2) a Polaroid polarizer, and (3) two quartz plates.

Journal Article↗