PubMed Health⌕ Search

Biomedical subjects

Christopher M Snively

Publications and source records attributed to Christopher M Snively.

5 recordsLinked to original sources

High-throughput heterogeneous catalytic science.

High-throughput experimentation in heterogeneous catalysis has recently experienced nearly exponential growth. Initial qualitative screening has evolved into quantitative high-throughput experimentation, characterization, and analysis. This allows high-throughput catalysis now to rise above simple screening to the level of fundamental understanding of reaction mechanisms, which will lead on a faster path to the Holy Grail of catalysis: rational catalyst design.

Journal Article↗

Experimental aspects of asynchronous rapid-scan fourier transform infrared imaging.

In the asynchronous, rapid-scan approach to Fourier transform infrared (FT-IR) imaging, data sampling is not correlated with the zero crossings of the interference fringes of the HeNe reference laser. The success of this data collection scheme depends on the reproducibility of the clock signals driving the interferometer mirror and focal plane array data collection. In previous studies, it was shown that this implementation provides for markedly faster data acquisition without sacrificing data quality, as compared with stepscan imaging. This approach to data collection introduces some unique peculiarities to the acquisition and processing of imaging data. The purpose of this paper is to address a few of these concerns in terms of their effect on final data quality. Also, the practical aspects of implementing such an acquisition scheme are described in detail.

Calibration↗

Acquisition of mid-infrared spectra from nonrepeatable events with sub-100-micros temporal resolution using planar array infrared spectroscopy.

A novel method is presented that is capable of collecting time-resolved vibrational spectroscopic information with sub-100-micros temporal resolution. Unlike previous step scan FT-IR approaches, the phenomena under study do not necessarily need to be repeatable. The methodology described herein is based on the planar array infrared (PA-IR) technique, which utilizes a spectrograph for wavelength dispersion and a mid-infrared focal plane array (FPA) detector for simultaneous detection of multiple wavelengths. Unlike previous PA-IR approaches, a rolling mode FPA is employed. This unique data readout mode, where data are read out of the array two rows at a time, is exploited to generate increased temporal resolution. The capabilities of this technique are demonstrated using the example of the electric field-induced Freedericksz transition of a nematic liquid crystal. It is shown that the orientational dynamics of a single transition can be tracked over a spectral range of 154 cm(-)(1) with a temporal resolution of 99.17 micros while requiring a total experimental time of less than 1 s.

Journal Article↗

Performance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.

A no-moving-part planar array infrared spectrograph (PA-IR) equipped with a 256 x 256 mercury cadmium telluride (MCT) focal plane array has been designed and constructed. The performance of the instrument, whose frequency range extends from 2000-975 cm(-1), has been assessed in terms of resolution, bandwidth, and signal-to-noise ratio. The PA-IR spectrograph is able to record spectra with an 8.7 ms time resolution and has peak-to-peak noise levels as low as 2.4 x 10(-4) A.U. As a demonstration of the potential of PA-IR, the dynamics of reorientation of a liquid crystalline sample exposed to a single electric field pulse has been studied. It was shown that PA-IR can be used for the simultaneous acquisition of two orthogonally polarized spectra. The advantages and limitations of PA-IR, step-scan Fourier transform infrared (FT-IR), and ultrarapid-scanning FT-IR for real-time studies of reversible and irreversible phenomena are thoroughly discussed.

Polymers↗