PubMed Health⌕ Search

Biomedical subjects

Christopher P Reinhardt

Publications and source records attributed to Christopher P Reinhardt.

2 recordsLinked to original sources

Method to quantify tail vein injection technique in small animals.

Injection errors, which are often not readily recognized, can greatly impact the outcome of a pre-clinical research study. As a result, unrecognized misadministration of test compounds can render a high cost to the biomedical community. In this report, we propose six criteria for a reagent designed to assess tail vein injection technique in small animals and suggest a reagent, colloidal gold labeled with the stable isotope 197Au, that satisfies these criteria, thereby describing and validating for the first time a method to quantify technical compliance in tail vein injections. In an application of this reagent, we show the degree of variation experienced by technologists performing tail vein injection procedures in mice. In this study, mice were manually restrained and received an injection in the tail vein. One hour after injection, the mice were euthanized, various organs including the tail (the site of the injection) were collected, and their gold content was quantified by neutron activation. The three experienced animal technologists in the study were tested for tail vein injection proficiency in 30 mice. Prior to the study, the supervisor stated that a misinjection occurs when more than 10% of the intended volume remains in the tail. In light of this criterion, 12 of the 30 injections were misadministered: two with technologist 1, three with technologist 2, and seven with technologist 3. Although she was able to correctly rank the injection skills of the three technologists used in this experiment, i.e., technologist 1 and 2 more better skilled than technologist 3, the supervisor greatly underestimated the extent and degree of injection failures for the procedure. The results of the study illustrate the potential problems associated with the technical compliance with this common laboratory procedure and suggest that there is a need to validate injection methods and a need to monitor technical competence. Application of reagents similar to colloidal gold and the methods presented will facilitate the development of improved methods of teaching injection technique and monitoring technical quality in the laboratory setting. In Vivo Micro Computed Tomography of Subchondral Bone in the Rat After Intra-articular Administration of Monosodium Iodoacetate

Animals↗

Neutron-activation analysis: a novel method for the assay of iohexol.

Accurate measurement of glomerular filtration rate (GFR) is of great importance in both research and clinical medicine. Available methods require radiation exposure or are technically difficult, thereby limiting their utility. Recent work has validated plasma clearance of nonradioactive contrast agents (iohexol and iothalamate) for the measurement of GFR. However, their clinical utility has been restricted by the difficulties associated with the detection of contrast agents in serum. In this investigation, we evaluate the sensitivity, accuracy and precision of neutron activation analysis (NAA) to measure serum iohexol at concentrations necessary for estimating GFR. We subjected aliquots of serum containing 0 to 6470 microg/mL iohexol to neutron activation by placing them in a neutron beam for 1 minute. The activation process resulted in the elevation of iohexol's naturally abundant iodine 127 to iodine 128. The spontaneous decay of (128)I to xenon 128 (proportional to the amount of total iodine in the sample) was calculated by means of spectrographic analysis. The correlation between the predetermined elemental mass of iodine in the sample and that measured on NAA was then determined. A similar analysis was performed to establish the intra- and interday accuracy and precision, with multiple measurements taken over a single day and over the course of a month. We noted excellent correlation between iodine measured on NAA and the known elemental mass (r(2) =.99). Measurements were highly accurate (mean accuracy 2.4% +/- 1.8%), with excellent intra- and interday reliability (mean coefficient of variation 4.1% +/- 1.6%). NAA is a feasible and reproducible method of detecting iohexol for the purpose of measuring GFR.

Glomerular Filtration Rate↗