PubMed Health⌕ Search

Biomedical subjects

Christopher Y Kim

Publications and source records attributed to Christopher Y Kim.

8 recordsLinked to original sources

Assessment of mRNA Decay and Calculation of Codon Occurrence to mRNA Stability Correlation Coefficients after 5-EU Metabolic Labeling.

mRNA translation and decay are tightly connected. This chapter describes a method to assess the influence of each codon identity on mRNA stability in cultured cells. The technique involves metabolic labeling of the nascent mRNAs by addition of the nucleoside analog 5-ethynyluridine (5-EU), purification of the RNA at different time-points after chase of the 5-EU, then biotinylation with Click chemistry, pull-down, and sequencing. The transcripts' half-lives are calculated from the expression level of each mRNA at the different time-points. Finally, the method describes the calculation of the Codon occurrence to mRNA Stability correlation Coefficient, or CSC, as a correlation between the codon occurrence in a transcript and the transcript half-life, for each codon.

RNA Stability↗

Tele-endoscopy: a way to provide diagnostic quality for remote populations.

BACKGROUND: Flexible endoscopy plays an important role in digestive health. However, access to endoscopy is limited in many rural areas throughout the world. Training non-physician personal to perform diagnostic endoscopy and to transmit images to a central hospital, where experienced endoscopists can review the procedures, may improve digestive health for patients in remote areas. The aim of this study was to evaluate the diagnostic quality and accuracy of upper-GI tele-endoscopy. METHODS: Fifty patients scheduled for EGD underwent upper-GI tele-endoscopy. The procedures were observed simultaneously by the endoscopist and a gastroenterologist observing from a remote station connected by 4 integrated services digital network telephone lines. The interpretation of the findings by both were compared and concordance for diagnosis of major and minor lesions was analyzed. RESULTS: Tele-endoscopic image quality was adequate to support diagnosis of abnormal lesions by the remote observer. Technical issues included worsening image quality caused by mild pixelation during rapid endoscope movement and rare loss of the telephone lines. The endoscopist identified 47 different major and 44 minor findings in the 50 patients. The observer missed one major lesion (columnar-lined esophagus) because of suspected inflammation and described 10 non-existing major lesions (sensitivity 98%: 95% CI[89%, 99%], specificity 80%: 95% CI[66%, 90%]). Some of the differences were because of interobserver variability. CONCLUSIONS: Upper-GI tele-endoscopy by using telephone lines has good diagnostic quality and is highly sensitive with regard to major findings. The misinterpretation of certain findings (esophageal ring, gastric erosions) may be caused by interobserver variability. The data strongly suggest that endoscopist and observer see similar endoscopic views.

Adult↗

Cost-effectiveness of screening a population with chronic gastroesophageal reflux.

BACKGROUND: Persons with chronic esophageal reflux are at increased risk for the development of Barrett's esophagus and adenocarcinoma. Recently developed ultrathin endoscopes are less expensive and better tolerated than standard endoscopes, they can be used without sedation, and are sensitive and specific for Barrett's esophagus. The cost-effectiveness of one-time screening strategies were evaluated for 50-year-old patients with chronic reflux: no screening, standard endoscopy, and screening by an ultrathin endoscope. METHODS: Markov models were created to simulate the clinical course for patients with chronic reflux. Costs and quality-adjusted life-years were estimated from cancer registry data, published medical data, and expert opinion. RESULTS: Under baseline assumptions, no screening resulted in average costs of $11,785 per person and 19.3226 quality-adjusted life-years. Ultrathin endoscopy screening resulted in costs of $12,119 per person and 19.3326 quality-adjusted life-years, yielding a marginal cost-effectiveness ratio of $55,764 per quality-adjusted life-year. Using standard endoscopy yielded costs of $12,332 with only slightly greater effectiveness, yielding a marginal cost-effectiveness ratio of $709,260 when compared with ultrathin endoscopy and $86,833 compared with no screening. Results were most sensitive to variation in the incidence of cancer in the population with Barrett's esophagus. CONCLUSIONS: Screening for Barrett's esophagus with ultrathin endoscopy is more cost-effective than standard endoscopy, and both strategies appear to improve quality-adjusted life-years among patients with chronic reflux at costs that are similar to those of other accepted preventive measures.

Adenocarcinoma↗

Accuracy of esophagoscopy performed by a non-physician endoscopist with a 4-mm diameter battery-powered endoscope.

BACKGROUND: A cost-effective technique is needed for screening of a broad population at risk for esophageal cancer. A solution would be to have non-physician endoscopists perform esophagoscopy with small-caliber battery-powered endoscopes. METHODS: In a prospective blinded study, the diagnostic accuracy of sedated esophagoscopy performed by a trained nurse practitioner with a battery-powered 4-mm diameter endoscope was compared with that for a sedated standard video-endoscopy performed by a gastroenterologist. Patients were recruited to undergo peroral esophagoscopy by the nurse practitioner followed by sedated standard endoscopy by the supervising gastroenterologist, each blinded to the findings of the other. Major esophageal findings of nurse practitioner and gastroenterologist were compared. RESULTS: Findings in 40 patients were analyzed. In 4 patients both endoscopists could not assess the presence or absence of columnar-lined esophagus because of severe erosive esophagitis (n = 3) or severe candida-esophagitis (n = 1). By using sedated standard endoscopy as the standard, on a per finding basis, esophagoscopy by the nurse practitioner had a sensitivity for columnar-lined esophagus of 89%: 95% CI [75%, 97%] and specificity of 96%: 95% CI [84%, 99%]. The missed columnar epithelium was a 3 x 3-mm island. For all lesions, the sensitivity of endoscopy performed by the nurse practitioner with the battery-powered endoscope was 75%: 95% CI [67%, 82%] and specificity 98%: 95% CI [96%, 99%]. The nurse practitioner missed all of 4 rings (3 considered clinically irrelevant). CONCLUSION: Esophagoscopy with a battery-powered 4-mm diameter endoscope by a non-physician endoscopist is feasible and accurate in detecting esophageal pathologies. It may be an efficient screening method for the detection of columnar-lined esophagus. There was a distinct underestimate of the presence of esophageal rings.

Barrett Esophagus↗

A prospective, blinded study of diagnostic esophagoscopy with a superthin, stand-alone, battery-powered esophagoscope.

OBJECTIVES: A more widely available, well-tolerated, and cost-effective technique is needed to screen a broad population at risk for esophageal cancer. An ideal solution might be to perform unsedated esophagoscopy with an entirely self-contained, small-caliber endoscope. In a prospective, blinded study in three phases, we compared the feasibility, patient tolerance, and diagnostic accuracy of esophagoscopy performed with a prototype, superthin, battery-powered esophagoscope (BPE) with standard video esophagogastroduodenoscopy (SVE). METHODS: In phase I, 10 healthy volunteers underwent both peroral and transnasal esophagoscopy with BPE to evaluate the technical feasibility of the examination. For phases II and III, patients were recruited to have BPE before SVE. In phase II, both procedures were performed with conscious sedation. In phase III, the BPE was performed with only topical anesthesia. Two endoscopists assessed the technical performance of the endoscope and patient tolerance and recorded the esophageal findings independently. RESULTS: In phase I, all endoscopists reported adequate visualization of the esophagus in the 10 volunteers. A total of 181 patients were evaluated in phases II and III (89 in phase II, 92 in phase III). The sensitivity for detecting columnar lined esophagus was 94% in phase II and 95% in phase III. The sensitivity for all esophageal findings was 87% and 86% in phases II and III, respectively. The technical performance of the endoscope was significantly worse for BPE compared with the SVE. The patient tolerance as evaluated by the endoscopist was similar for both procedures. Ninety-five percent of the patients undergoing unsedated BPE were willing to have the procedure repeated under similar circumstances. CONCLUSIONS: Unsedated esophagoscopy with a 3.1-mm, battery-powered, stand-alone esophagoscope is feasible, well tolerated, and accurate in detecting esophageal pathologies. It might be an efficient and cost-effective screening tool for the detection of columnar lined esophagus.

Adult↗

High-resolution chromoendoscopy for classifying colonic polyps: a multicenter study.

BACKGROUND: Chromoendoscopy may reliably separate adenomatous from nonadenomatous polyps. The aim of this multicenter trial was to determine the accuracy of high-resolution chromoendoscopy for the determination of colonic polyp histology. METHODS: This multicenter trial included 4 academic centers and a primary care practice. In 299 patients referred for routine colonoscopy or sigmoidoscopy, 520 polyps 10 mm in size were sprayed with indigo carmine dye. Using a high-resolution endoscope, the endoscopist predicted the histology of each polyp based on its surface characteristics. Hyperplastic polyps had a "pitted" surface pattern of orderly arranged "dots" that resembled surrounding normal mucosa. Adenomatous polyps had at least one surface "groove" or "sulcus." Each polyp was subsequently resected for histopathologic evaluation. RESULTS: The resected polyps were comprised by 193 adenomas (37%), 225 hyperplastic polyps (43%), and 102 "other" types (20%). Forty polyps (7.7%) could not be classified by high resolution chromoendoscopy with indigo carmine dye. For the remaining polyps, the sensitivity, specificity, and negative predictive value of indigo carmine dye staining for adenomatous polyps were, respectively, 82%, 82%, and 88%. The results were consistent among the academic centers and the primary care practice. CONCLUSIONS: High-resolution chromoendoscopy with indigo carmine dye demonstrates morphologic detail of diminutive colorectal polyps that can reliably be used to separate adenomatous from nonadenomatous polyps.

Adenoma↗

Endoscopic removal of large colonic lipomas.

BACKGROUND: Colonic lipomas are benign adipose tumors that rarely cause symptoms. Removal of lipomas 2 cm or greater in diameter has been associated with a greater risk of perforation. Experience with the evaluation and removal of large colonic lipomas with the assistance of EUS to reduce the risk of perforation is reported. METHODS: Four patients with large colonic lipomas were evaluated and treated with endoscopic methods. EUS was performed to confirm that the lesion was a lipoma superficial to the muscularis propria. Saline or epinephrine solution was injected at the base of the tumor, which was then resected electrosurgically with a snare. OBSERVATIONS: All 4 lesions were successfully removed and histopathologically confirmed to be lipomas (mean maximal diameter 2.8 cm). There were no complications of any procedure. One patient was hospitalized overnight because of abdominal pain that resolved without complication. CONCLUSIONS: Large colonic lipomas can be removed safely by electrosurgical snare resection after injection of the base with epinephrine or saline solution. EUS should be used to ensure that the lipoma does not extend into the muscularis propria. Clinical judgment is important in assessing the need to remove these lesions.

Adult↗

U.S. veterans' experience with rebetron in a nonstudy environment: success or failure?

OBJECTIVE: The aim of this study is to report the clinical response observed in a U.S. veteran population with hepatitis C to combination therapy with Rebetron (interferon/ribavirin) outside of a controlled study environment. METHODS: Ninety-nine consecutive patients with hepatitis C who met the approved guidelines for treatment were offered treatment with Rebetron. Ninety-four patients initiated therapy. All patients received formal instruction on the use of the drug, as well as the side effects and were instructed to report any side effects. Follow-up was scheduled twice a month for the first month, then monthly unless adverse events were observed. RESULTS: Ninety-four of 99 patients initiated therapy. Thirty-two patients were lost to follow-up or did not tolerate therapy. Ethnic distribution comprised 56 whites, 42 African Americans, one Hispanic. Of the 56 whites who started therapy, 39 completed treatment. Sustained viral response (SVR) for all genotypes was observed in 10 of 39 (26%). In the African American patients, 22 of 42 (52%) completed therapy, but a SVR was noted in none. The only Hispanic patient did not respond to therapy. In the veteran population, favorable factors associated with achieving SVR included having genotype other than 1, absence of cirrhosis, and ethnicity. Factors contributing to the low response rates were difficulty in adhering to therapy as well as a predominance of genotype 1. CONCLUSIONS: Using an intention-to-treat analysis, only 10% of veterans achieved SVR. These findings highlight the need to develop a multidisciplinary team to address the complexity of treating the veteran patient with hepatitis C.

Adult↗