PubMed Health⌕ Search

Biomedical subjects

Chrit Moonen

Publications and source records attributed to Chrit Moonen.

2 recordsLinked to original sources

Intraluminal high intensity ultrasound treatment in the esophagus under fast MR temperature mapping: in vivo studies.

New curative and palliative treatments are needed to respond to the poor prognosis of esophageal cancer. The purpose of this study was to determine whether magnetic resonance imaging (MRI) and MR thermometry can be used to monitor the thermal ablation induced by an intraluminal high-intensity ultrasound applicator positioned in the esophagus. Experiments were performed in vivo in 2 pig esophagi (25 thermal lesions per pig). Respiratory gated or cardiac gated MR thermometry was performed with segmented echo-planar imaging gradient echo sequences. All MR acquisitions were performed without susceptibility artifacts or radiofrequency interference with the ultrasound device. The experimental procedure proposed for accurate measurement of temperature in the esophagus was found to achieve an SD of +/- 1.5 degrees C for respiratory gating and +/- 3.1 degrees C for cardiac gating. Gd-enhanced T(1)-weighted images were used to depict coagulation necrosis. Autopsy was performed immediately after the treatment. Ultrasound effects were inspected visually, and the dimensions of the lesions in the liver neighboring the esophagus were compared with those determined on the MRI images. The visually assessed thermal lesions showed good correlation with the MRI data (10% mean volume difference). The feasibility of esophageal thermal ablation using intraluminal high-intensity ultrasound and of on-line MR temperature monitoring was demonstrated.

Animals↗

Quantitative cerebral perfusion using the PRESTO acquisition scheme.

PURPOSE: To evaluate the feasibility of using the rapid principles of echo shifting with a train of observations (PRESTO) sequence for measurements of cerebral hemodynamic parameters based on first pass of a contrast agent. MATERIALS AND METHODS: Simulations were performed to investigate potential resolution loss due to relaxation effects. Experimental evaluation was conducted in healthy monkey brains using PRESTO and echo-planar imaging (EPI). RESULTS: For short echo trains, an insignificant contribution of the longitudinal and transversal relaxation rates to the signal amplitude in white matter and gray matter was found, whereas a contribution as large as 40% was found in large vessels. Simulations of the point spread function demonstrated that PRESTO, despite its shorter readout trains, only has a small advantage in terms of maintenance of image resolution during bolus passage compared to EPI as long as the EPI echo train can be kept similar to the T2* value at the top of the bolus. Experimental studies revealed that the PRESTO and EPI gray matter to white matter ratio were similar with respect to cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). CONCLUSION: The study showed that PRESTO and EPI led to comparable quantitative perfusion parameters.

Animals↗