Helical tomotherapy shielding calculation for an existing LINAC treatment room: sample calculation and cautions.

This paper reports a step-by-step shielding calculation recipe for a helical tomotherapy unit (TomoTherapy Inc., Madison, WI, USA), recently installed in an existing Varian 600C treatment room. Both primary and secondary radiations (leakage and scatter) are explicitly considered. A typical patient load is assumed. Use factor is calculated based on an analytical formula derived from the tomotherapy rotational beam delivery geometry. Leakage and scatter are included in the calculation based on corresponding measurement data as documented by TomoTherapy Inc. Our calculation result shows that, except for a small area by the therapists' console, most of the existing Varian 600C shielding is sufficient for the new tomotherapy unit. This work cautions other institutions facing the similar situation, where an HT unit is considered for an existing LINAC treatment room, more secondary shielding might be considered at some locations, due to the significantly increased secondary shielding requirement by HT.

Equipment Design↗

An assessment of biologically-based optimization (BORT) in the IMRT era.

The purpose of this study was to investigate the role of biological-based IMRT (BORT) in treatment planning development; more specifically, to assess the possible advantages of BORT over the classic 3-dimensional conformal radiation therapy (3DRT) and dose-based IMRT based on quantitative and qualitative indices. Three clinical cases are presented to evaluate the differences of BORT, IMRT, and 3DRT. 3DRT, IMRT, and BORT plans were generated for each case using a commercially available treatment planning system (Pinnacle by Philips). The plans were compared by evaluating biological endpoints such as tumor control probability (TCP), normal tissue control probability (NTCP), and uncomplicated tumor control probability (P+), as well as isodose line distribution, dose-volume histograms (DVHs), and dose uniformity. In all cases of this study, BORT yielded improved isodose coverage and P+. Our preliminary results suggest that BORT could play an important role in treatment planning optimization, especially as biological models and predictive assays become more accurate. Further case studies are needed to establish a definitive role for this type of optimization.

Brain Neoplasms↗

Characterization of a novel toxin-antitoxin module, VapBC, encoded by Leptospira interrogans chromosome.

Comparative genomic analysis of the coding sequences (CDSs) of Leptospira interrogans revealed a pair of closely linked genes homologous to the vapBC loci of many other bacteria with respect to both deduced amino acid sequences and operon organizations. Expression of single vapC gene in Escherichia coli resulted in inhibition of bacterial growth, whereas co-expression of vapBC restored the growth effectively. This phenotype is typical for three other characterized toxin-antitoxin systems of bacteria, i.e., mazEF, relBE and chpIK. The VapC proteins of bacteria and a thermophilic archeae, Solfolobus tokodaii, form a structurally distinguished group of toxin different from the other known toxins of bacteria. Phylogenetic analysis of both toxins and antitoxins of all categories indicated that although toxins were evolved from divergent sources and may or may not follow their speciation paths (as indicated by their 16s RNA sequences), co-evolution with their antitoxins was obvious.

Amino Acid Sequence↗

Fast treatment plan modification with an over-relaxed Cimmino algorithm.

A method to quickly modify a treatment plan in adaptive radiotherapy was proposed and studied. The method is based on a Cimmino-type algorithm in linear programming. The fast convergence speed is achieved by over-relaxing the algorithm relaxation parameter from its sufficient convergence range of (0, 2) to (0, infinity). The algorithm parameters are selected so that the over-relaxed Cimmino (ORC) algorithm can effectively approximate an unconstrained re-optimization process in adaptive radiotherapy. To demonstrate the effectiveness and flexibility of the proposed method in adaptive radiotherapy, two scenarios with different organ motion/deformation of one nasopharyngeal case were presented with comparisons made between this method and the re-optimization method. In both scenarios, the ORC algorithm modified treatment plans have dose distributions that are similar to those given by the re-optimized treatment plans. It takes us using the ORC algorithm to finish a treatment plan modification at least three times faster than the re-optimization procedure compared.

Algorithms↗

Optimizer convergence and local minima errors and their clinical importance.

Two of the errors common in the inverse treatment planning optimization have been investigated. The first error is the optimizer convergence error, which appears because of non-perfect convergence to the global or local solution, usually caused by a non-zero stopping criterion. The second error is the local minima error, which occurs when the objective function is not convex and/or the feasible solution space is not convex. The magnitude of the errors, their relative importance in comparison to other errors as well as their clinical significance in terms of tumour control probability (TCP) and normal tissue complication probability (NTCP) were investigated. Two inherently different optimizers, a stochastic simulated annealing and deterministic gradient method were compared on a clinical example. It was found that for typical optimization the optimizer convergence errors are rather small, especially compared to other convergence errors, e.g., convergence errors due to inaccuracy of the current dose calculation algorithms. This indicates that stopping criteria could often be relaxed leading into optimization speed-ups. The local minima errors were also found to be relatively small and typically in the range of the dose calculation convergence errors. Even for the cases where significantly higher objective function scores were obtained the local minima errors were not significantly higher. Clinical evaluation of the optimizer convergence error showed good correlation between the convergence of the clinical TCP or NTCP measures and convergence of the physical dose distribution. On the other hand, the local minima errors resulted in significantly different TCP or NTCP values (up to a factor of 2) indicating clinical importance of the local minima produced by physical optimization.

Algorithms↗

Treatment plan modification using voxel-based weighting factors/dose prescription.

Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used organ-/ROI-based weighting factors are expanded to a set of voxel-based weighting factors in order to obtain greater flexibility in treatment plan modification. Two different but equivalent modification schemes based on Rustem's quadratic programming algorithms--modification of a weighting matrix and modification of prescribed doses--are presented. Case studies demonstrated the effectiveness of the two methods with regard to their capability to fine-tune treatment plans.

Algorithms↗

The method of intercepts in parameter space for the analysis of local minima caused by dose-volume constraints.

The local minima problem in radiotherapy optimization has been a concern for both researchers and physicians. In this work, local minima induced by dose-volume histogram (DVH) constraints are discussed. The non-convex property of the feasible set formed by DVH constraints is discussed in beam weight space. An intuitive explanation of the origin of this type of local minima is given by a two-beam model setup. Some interesting properties and insights about the DVH-induced local minima are found. Based on this, a heuristic non-random initial guess sampling method is proposed and applied to a clinical nasopharyngeal case, where some significantly different local minima are located.

Algorithms↗

Image guidance for precise conformal radiotherapy.

PURPOSE: To review the state of the art in image-guided precision conformal radiotherapy and to describe how helical tomotherapy compares with the image-guided practices being developed for conventional radiotherapy. MATERIALS AND METHODS: Image guidance is beginning to be the fundamental basis for radiotherapy planning, delivery, and verification. Radiotherapy planning requires more precision in the extension and localization of disease. When greater precision is not possible, conformal avoidance methodology may be indicated whereby the margin of disease extension is generous, except where sensitive normal tissues exist. Radiotherapy delivery requires better precision in the definition of treatment volume, on a daily basis if necessary. Helical tomotherapy has been designed to use CT imaging technology to plan, deliver, and verify that the delivery has been carried out as planned. The image-guided processes of helical tomotherapy that enable this goal are described. RESULTS: Examples of the results of helical tomotherapy processes for image-guided intensity-modulated radiotherapy are presented. These processes include megavoltage CT acquisition, automated segmentation of CT images, dose reconstruction using the CT image set, deformable registration of CT images, and reoptimization. CONCLUSIONS: Image-guided precision conformal radiotherapy can be used as a tool to treat the tumor yet spare critical structures. Helical tomotherapy has been designed from the ground up as an integrated image-guided intensity-modulated radiotherapy system and allows new verification processes based on megavoltage CT images to be implemented.

Animals↗

Re-optimization in adaptive radiotherapy.

In routine clinical practice, radiotherapy treatment planning is performed based on the patient CT images obtained during the patient setup procedure. However, the actual delivered dose to the patient might be different from the planned dose because of various reasons such as patient motion. Under such situations, it is desirable to modify the original treatment plan in order to partially remedy the dose delivery errors in the subsequent dose delivery process. Such modification can be implemented by modifying the original treatment plan using re-optimization. In this work, issues such as the re-optimization dose prescription, optimization constraints in re-optimization, re-optimization in multiple fractionation schemes and re-optimization procedure with generalized dose-based objective functions were investigated and corresponding mathematical schemes proposed. The derived results were applied to a clinical case study in which it was shown that the proposed re-optimization method is able to remedy the cold spots in tumour while delivering low dose to normal structures. Thus the potential effectiveness of the method was demonstrated.

Algorithms↗