PubMed Health⌕ Search

Biomedical subjects

Chuen-Ying Liu

Publications and source records attributed to Chuen-Ying Liu.

14 recordsLinked to original sources

Capillary electrochromatographic separation of proteins on a column coated with titanium dioxide nanoparticles.

A TiO2 nanoparticle (TiO2 NP)-coated open-tubular column for the capillary electrochromatographic separation of proteins is described. The surface chemistry of the TiO2 NPs on the inner wall of the fused silica was significantly affected by the running buffer. By varying of the phosphate buffer pH, only cathodic EOF was indicated. The results showed that TiO2 NPs are existed as a complexed form with the buffer ligand. Good separation of conalbumin (ConA), apo-transferrin (apoTf), ovalbumin (OVA), and BSA could be achieved with phosphate buffer (40 mM, pH 8.0) and an applied voltage of 15 kV. Five peaks of glycoisoforms of OVA were observed under these conditions. In comparison with the retention behavior of the analytes on the bare fused-silica column, the new column's high resolving power seems to be predominantly derived from the ligand exchange of the analytes with the phosphate adsorbed onto the TiO2 NPs. The method was also used to separate egg-white proteins. Both acidic and basic proteins in egg white were separated in a single run. The microheterogeneities of OVA could also be found in it. The separation efficiency for the main peak of OVA in egg white was around 10,000 plates/m.

Animals↗

Speciation of selenium compounds by open tubular capillary electrochromatography-inductively coupled plasma mass spectrometry.

We introduce a T-type interface and a crossflow nebulizer to find ways to combine CEC with inductively coupled plasma MS (ICP-MS) detection for selenium speciation. For CEC separation, we employed a macrocyclic polyamine-bonded phase capillary as the separation column and a bare fused-silica capillary filled with the make-up liquid (0.05 M HNO3). The effect of nebulizer gas flow rate, make-up liquid flow, type, concentration and pH of the mobile phase on the separation have been studied. Tris buffer of 50 mM at pH 8.50 gave the best performance for selenium speciation. The reproducibility of the retention time indicated that sample injection by electrokinetic and nebulizer gas flow was better than that by self-aspiration alone. The detection limits for selenate, selenite, selenocystine and selenomethionine were found to be 2.40, 3.53, 12.86 and 11.25 ng/mL, respectively. Due to the high sensitivity and element-specific detection, as well as the high selectivity of the bonded phase, quantitative analysis of selenium speciation in urine was also achieved.

Buffers↗

Phase transfer of gold nanoparticles from aqueous to organic solution containing resorcinarene.

Citrate-capped gold nanoparticles (NPs) in aqueous solution were transferred directly into the organic solution mesitylene containing C-undecylcalix[4]-resorcinarene (C11-resorcinarene). C11-resorcinarene, which has long hydrophobic tails and phenolic hydroxyl groups, acted as both a phase-transfer and a capping agent. The C11-resorcinarene-capped gold particles could be isolated and dispersed in different organic solvents. Optical absorption spectra corresponding to surface plasmon resonance provided a broad band centered at 534 nm for C11-resorcinarene-capped gold NPs in mesitylene. High-resolution transmission electron micrograph images revealed that the average particle diameter of C11-resorcinarene-capped gold NPs is approximately 12 nm.

Calixarenes↗

Titanium dioxide nanoparticles-coated column for capillary electrochromatographic separation of oligopeptides.

A novel column made through the condensation reaction of TiO2 nanoparticles (TiO2 NPs) with silanol groups of the fused-silica capillary is described. EOF measurements under various buffer constitutions were used to monitor the completion of reactions. The results indicated that the EOF was dependent on the interactions between buffers and the bonded TiO2 NPs. With formate/Tris buffer, EOF reversal at pH below 5 and cathodic EOF at pH above 5 were indicated. The pI of the bonded TiO2 NPs was found at approximately ph 5. Only cathodic EOF was illustrated by substituting the mobile phase with either glutamate or phosphate buffer. It was elucidated that both glutamate and phosphate buffer yield a negative charge layer on the surface of TiO2 NPs attributable to the formation of a titanium complex. The CEC performance of the column was tested with angiotensin-type oligopeptides. Some parameters that would affect the retention behavior were investigated. The interactions between the bonded phases and the analytes were explicated by epitomized acid-base functional groups of the oligopepetides and the speciation of the surface oxide in different pH ranges. The average separation efficiencies of 3.1 x 10(4) plates/m is readily achieved with a column of 70 cm (50 cm) x 50 mum ID under an applied voltage of 15 kV, phosphate buffer (pH 6.0, 40 mM), and UV detection at 214 nm.

Angiotensins↗

Polystyrene monolithic column functionalized with copper-iminodiacetate complex as a stationary phase for open tubular capillary electrochromatography.

Polystyrene-divinylbenzene copolymer functionalized with copper-iminodiacetate complex was prepared in situ for the capillary electrochromatographic separation of amino acids and oligopeptides. The steps included silanization of the fused-silica capillary column, functionalization, polymerization, hydrolysis and complexation. For having a homogeneous polymerization system in the selected porogen, the functional monomer was obtained from the reaction of 4-vinylbenzyl chloride and diethyl iminodiacetate. Scanning electron microscopy showed that the polymeric monolith column was an open tubular column with a thickness of 0.3 microm. Various modes of hydrolysis were investigated via the electroosmatic flow measurement to find the optimization condition prior to introducing the copper ion. The influence of pH, composition and concentration of mobile phase as well as the organic modifier were investigated. Judging from our results, the recognition performance of the prepared stationary phase might be integrated from the mechanisms of ligand exchange, electrophoretic mobility, hydrophobic interaction, and hydrogen bonding.

Chromatography, Micellar Electrokinetic Capillary↗

Preparation and evaluation of nickelmesogen for micropacked gas chromatography.

The preparation and mesomorphic properties of a substituted bis(dithiolene)nickel complex derived from 4, 4'-dimethoxybenzil are reported. The phase transition temperatures were based on data obtained by polarized light microscopy and differential scanning calorimetry. The mesogenic phase existed over the temperature range from 77 to 175 degrees C. A novel micropacked column (1.5 or 3 m x 1 mm i.d.) prepared from the slurry of bis[1,2-bis(4-n-undecyloxyphenyl)ethane-1,2-dithiolene] nickel(II) (5%, w/w), coated on Chromosorb W was applied for the separation of dialkyl sulfides. The non-linearity (discontinuity) of Van't Hoff plots suggests that the liquid crystal property existed even in the coated phase. Factors affecting the retention and the sample selectivity on the prepared column were examined by using a flame photometric detector (FPD). The separation might be based on the mechanism of ligand exchange, shape selectivity and polarity interaction besides the vapor pressure. LOD for the determination of dialkyl sulfides was below 1 ng for most of the analytes.

Calibration↗

Preparation and evaluation of molecularly imprinted polymers based on 9-ethyladenine for the recognition of nucleotide bases in capillary electrochromatography.

A molecularly imprinted polymer (MIP) comprising 9-ethyladenine was polymerized in situ inside the capillary for the electrochromatographic separation of nucleotide bases. The capillary wall was first functionalized with 3-trimethoxysilylpropyl methacrylate (10% v/v) and 1,1-diphenyl-2-picrylhydrazyl (0.01% w/v) in toluene. Following this treatment, the capillary was filled with acetonitrile containing 9-ethyladenine, methacrylic acid, ethylene glycol dimethacrylate, and initiator. After polymerization, the MIP was shrunk into a film against the inner wall of the capillary with the syringe pump. The template was then removed with methanol under nitrogen flow. For evaluation the feasibility of the MIP column for the separation of nucleotide bases, some parameters including the pH, concentration of the background electrolyte, the applied voltage as well as the effect of organic modifier were studied. The migration behavior of nucleotide bases on the MIP column was also compared with that on the bare fused-silica column. The results indicated that the MIP columns demonstrated better recognition properties at a pH range of 6-8. The efficiency (plates/m) at pH 8 for the nonimprinted analyte was 75,300 for cytosine, 50,200 for thymine, and 14,800 for guanine. However, the efficiency for the imprinted analyte, adenine, was quite low. This was evidenced by the broad peak, yielding only 2600 plates/m.

Adenine↗

Optimization of sample stacking for the simultaneous determination of nonsteroidal anti-inflammatory drugs with a wall-coated histidine capillary column.

A wall-coated histidine capillary column was developed for the on-line preconcentration of nonsteroidal anti-inflammatory drugs (NSAIDs) in capillary electrochromatography (CEC). A wide variety of experimental parameters, such as the sample buffer, background electrolyte (BGE) composition, concentration, sample plug lengths, water plug, and the effect of organic modifiers were studied. The relationship between peak height and injection times for the NSAIDs by variation of sample and BGE buffer concentration was investigated. On addition of sodium chloride (0.3-0.6%) to the sample zone, the stacking efficiency was increased. With acetate buffer (100 mM, pH 5.0)/ethanol (20% v/v) as BGE and sample solution in acetate buffer (0.2 mM, pH 5.0)/ethanol (20% v/v)/NaCl (0.3% w/v), NSAIDs could be determined at low microM levels without sample matrix removal. The detection limit was 0.096 microM for indoprofen, 0.110 microM for ketoprofen, 0.012 microM for naproxen, 0.023 microM for ibuprofen, 0.110 microM for fenoprofen, 0.140 microM for flurbiprofen, and 0.120 microM for suprofen. The method could be successfully applied to the simultaneous determination of NSAIDs in urine. The recoveries were better than 82% for all the analytes. The present method enables simple manipulation with UV detection for the determination of NSAIDs at low concentration levels in complex matrix samples.

Anti-Inflammatory Agents, Non-Steroidal↗

Proline-coated column for the capillary electrochromatographic separation of amino acids by in-column derivatization.

With 3-trimethoxysilylpropyl chloride as the spacer, a proline-coated capillary column was prepared for the capillary electrochromatographic (CEC) separation of amino acids by in-column derivatization. Nine standard mixtures, including aspartic acid, glutamic acid, valine, phenylalanine, alanine, isoleucine, leucine, tyrosine, and tryptophan, were injected. o-Phthalaldehyde (OPA), OPA/2-mercaptoethanol (2-ME) and OPA/N-acetylcysteine (NAC) in borate buffer were tested as the derivatizing agent. Among them, OPA (50 mM) in borate buffer (pH 9.5, 50 mM) gave the best performance. The formation of isoindole could be detected by UV detection. The sandwich-type injection was carried out in hydrostatic mode (10 cm) with the program R(10 s)S(10 s) R(10 s)W(10 min) with R, S, and W being the reagent, sample, and waiting times. Mesityl oxide, benzyl alcohol, and acetone showed some interaction with the column. A current monitoring method was used instead of the determination of the electroosmotic flow (EOF). The direction of EOF was from anode to cathode even under acidic condition lower than the pI value (6.31) of the bonded group due to some unreacted silanol groups. Some parameters including pH, nature, and concentration of the mobile phase and the effect of organic modifier with regard to the CEC separation were investigated. With the proline-coated column (75 (50) cm x 75 microm ID) the best separation was performed in phosphate buffer (pH 4.00, 100 mM) with an applied voltage of -15 kV. The established method was also compared with those precolumn derivatized prior to the separation with proline-coated column as well as with in-capillary derivatization and separation with a bare fused-silica column.

Amino Acids↗

An insight into molecularly imprinted polymers for capillary electrochromatography.

Molecularly imprinted polymers (MIPs) are actively being developed as a practical tool for affinity chromatographic supports. From the viewpoint of separation science, capillary electrochromatography (CEC) might be one of the more promising chromatographic techniques to be used in combination with the MIPs. However, up to the present, very little MIP work has involved CEC. This review gives a full overview of MIP including current trends in MIP, methods for the characterization of MIP, and methods for the preparation of MIP with particular emphasis on application of the resulting materials in CEC. To prepare MIPs with selectivity predetermined for a particular substance or group of structural analogues is an important factor for the development of a new format of CEC. From the fundamental research with the batch method, a better knowledge of imprint formation and imprint recognition will be helpful for expanding the application area of the combination of MIPs with CEC.

Chromatography, Liquid↗

An insight into the phenomena involved in a multiple-function stationary phase for the capillary electrochromatographic separation of 2'-, 3'-, and 5'-monophosphorylated nucleoside isomers.

The electrochromatographic separations of 2'-, 3'- and 5'-monophosphates of adenosine, guanosine, cytidine, and uridine were carried out with an open-tubular capillary column which was wall-coated with a highly selective reagent, 28-membered macrocyclic polyamine, 4, 8, 12, 18, 22, 26-hexaaza-1,15-dioxacyclooctaeicosane ([28]ane-N6O2). The effects of pH, composition and concentration of background electrolyte (BGE), applied voltage, column length, and the additive of the BGE, such as metal ions, borate, beta-cyclodextrin and organic solvent on the separation of these monophosphorylated nucleotide isomers were investigated. The results suggested that the interactions between analytes and the bonded groups on the wall predominantly comprise anion coordination and anion exchange in addition to the electrophoresis. A well-resolved electrochromatogram was obtained with the capillary column of 100 cm (75 cm effective length) x 75 microm inside diameter (ID), citrate buffer (20 mM, pH 3.99), applied voltage of -22 kV and detection at 254 nm. Column efficiency was found with the average theoretical plate numbers of 119,500/m and a low detection limit of 0.01 microM level could be achieved for the separation of these isomers.

Borates↗

Capillary electrochromatographic analysis of aliphatic mono- and polycarboxylic acids.

The parameters influencing the electrochromatographic separation of aliphatic organic acids in a capillary column with a wall-coated macrocyclic polyamine have been studied. Indirect detection using chromate, pyromellitate, trimellitate, o-phthalate, benzoate and acetate as background electrolytes has been tested. A complete separation of polyprotic acids could be achieved with pyromellitate buffer (7.5 mM, pH 6.5), and satisfactory results for the simultaneous separation of monoprotic acids and polyprotic acids were found using a capillary column of 70 cm (50 cm effective length)x75 microm inner diameter, electrokinetic injection (-10 kV, 10 s), benzoate buffer (6 mM, pH 4.6), separation voltage of -10 kV, and detection at 220 nm. For the separation of the geometric isomers fumarate and maleate, acetate buffer was found the best choice among the background electrolytes tested. The method so established has been applied to the determination of organic acids in soy sauce, brandy, lemon juice, spinach juice and cigarette. From the retention behavior, it was found that the separation mechanism on the bonded phase was influenced by the macrocyclic effect, electrostatic attraction, hydrogen bonding, van der Waals forces, and anion exchange, in addition to the differences in electrophoretic mobility.

Beverages↗

Capillary electrochromatographic separation of non-steroidal anti-inflammatory drugs with a histidine bonded phase.

An open tubular wall-coated capillary column containing histidine functional groups was prepared and employed for the capillary electrochromatographic separation of non-steroidal anti-inflammatory drugs. The anion exchange along with the hydrogen bonding and hydrophobic properties of the surface coating allowed the separation of analytes with very similar ionic mobility. Selectivity and resolution were studied by changing the pH over the range from 3.5 to 5.0 and the concentration of the buffer from 10 to 25 mM, as well as variation of the organic modifier, such as methanol, ethanol and 1-propanol over the range 7.5 to 20%. The optimum experimental conditions for the separation of a drug mixture, which consisted of indoprofen, ketoprofen, suprofen, naproxen, flurbiprofen, fenoprofen and ibuprofen were using a mixture of acetate buffer (20 mM, pH 5.0)-ethanol (1:5, v/v) as background electrolyte and an applied voltage of -20 kV with UV detection at 220 nm. The separation of these drugs could be achieved with an average plate number of 1.0 x 10(5) m(-1).

Anti-Inflammatory Agents, Non-Steroidal↗

Nucleoside monophosphates recognition using macrocyclic polyamine bonded phase in capillary electrochromatography.

An open-tubular wall-coated macrocyclic polyamine capillary column (70 cm x 75 microm ID) with 50 cm effective length for the separation of nucleoside monophosphates is described. Some parameters with respect to concentration, pH, composition of the buffer, and voltage in order to optimize the separation were studied. The coated capillary showed reversed electroosmotic flow (EOF), allowing anions to be separated in the co-EOF mode. Baseline separations were achieved for the eight nucleotides in less than 26 min using a background electrolyte consisting of H(3)PO(4)-NaH(2)PO(4) (30 mM, pH 3.10), an applied voltage of -15 kV, and detection at 254 nm. The macrocyclic polyamine on the capillary wall introduced anion coordination for the interaction with the analytes, the strength of which could be moderated by the type and concentration of the competing ion used in the background electrolyte (BGE). With a low concentration of the competing ion (phosphate ion), the migration behavior followed that obtained in the electrophoretic system. Increasing the concentration of the competing ion resulted in a faster migration and more complete elution of the analyte. The method established was also employed for the analysis of nucleotides in mushrooms. Aqueous extracts of mushrooms from different species and various extraction methods were injected directly for the analysis. Uridine 5'-monophosphate, guanosine 5'-monophosphate, adenosine 5'-monophosphate, and cytidine 5'-monophosphate, were found in the sample tested.

Agaricales↗