PubMed Health⌕ Search

Biomedical subjects

Chunguang G Yang

Publications and source records attributed to Chunguang G Yang.

2 recordsLinked to original sources

MASCOT HTML and XML parser: an implementation of a novel object model for protein identification data.

Protein identification using MS is an important technique in proteomics as well as a major generator of proteomics data. We have designed the protein identification data object model (PDOM) and developed a parser based on this model to facilitate the analysis and storage of these data. The parser works with HTML or XML files saved or exported from MASCOT MS/MS ions search in peptide summary report or MASCOT PMF search in protein summary report. The program creates PDOM objects, eliminates redundancy in the input file, and has the capability to output any PDOM object to a relational database. This program facilitates additional analysis of MASCOT search results and aids the storage of protein identification information. The implementation is extensible and can serve as a template to develop parsers for other search engines. The parser can be used as a stand-alone application or can be driven by other Java programs. It is currently being used as the front end for a system that loads HTML and XML result files of MASCOT searches into a relational database. The source code is freely available at http://www.ccbm.jhu.edu and the program uses only free and open-source Java libraries.

Databases, Protein↗

Investigation of the rapid scan on an electrospray ion trap mass spectrometer.

A rapid scan on a quadrupole ion trap mass spectrometer can improve the signal intensity by over 200 times when scanning at 12 times the normal scan rate. This intensity increase is due to a 5.5-fold increase in mass peak height due to a reduction in the mass peak width over time and a 40-fold increase in signal from the increased number of ions that can be trapped without the deleterious effects of space charge. Detection limits can be further improved by signal averaging more scans in the same period that is required for the normal scan, and the greatest advantage occurs when scanning over the full mass range. The rapid scan impacts the mass accuracy and the resolution is reduced by 6 times. The molecular weight determination of 40 fmol/microL apomyoglobin was determined in 3 s using a rapid scan, but this was not possible when using the normal scan rate. Quantitation results showed that the relative standard deviations for the total ion current peak areas of 500 fmol of angiotensin I were improved by a factor of 2.6 when the rapid scan was used.

Journal Article↗