PubMed Health⌕ Search

Biomedical subjects

Cinzia Stella

Publications and source records attributed to Cinzia Stella.

5 recordsLinked to original sources

Characterization and comparison of the chromatographic performance of different types of reversed-phase stationary phases.

The chromatographic performance of several base-deactivated stationary phases was evaluated with a specific chromatographic test. Seven basic test compounds, possessing different physico-chemical properties were injected on different supports with two mobile phases: one at pH 7.0 (acetonitrile-phosphate buffer, 40:60, v/v), and the other at pH 3.0 (acetonitrile-phosphate buffer, 15:85, v/v). Chromatographic parameters obtained under these conditions were treated by principal component analysis (PCA) to separate base deactivated supports according to their silanol activity (pH 7.0 mobile phase) and hydrophobic properties (pH 3.0 mobile phase). The information given by the specific test column evaluation was improved with complementary chemometric tools such as hierarchical cluster analysis. The same base deactivated supports were also tested following a general test procedure issued from the literature and obtained fundamental properties (in particular silanol activity and hydrophobicity) were compared with column evaluation obtained with the specific test: results were in good agreement, although the use of the specific test offered a better differentiation between numerous base-deactivated supports.

Chemical Phenomena↗

Susceptibility of human metabolic phenotypes to dietary modulation.

Dietary composition has been shown to influence metabolism and to impact on the prevalence and risk for certain diseases, but hitherto, there have been no systematic studies on the effects of dietary modulation of human metabolic phenotype (metabotype). Here, we have applied 1H NMR spectroscopy in combination with multivariate statistical analysis to characterize the effects of three diets: "vegetarian", "low meat", and "high meat" on the metabotype signature of human participants. Twelve healthy male participants (age range of 25-74 years) consumed each of these diets, in a randomized order, for continuous 15-day-periods with an intervening washout period between each diet of 7 days duration. Each participant provided three consecutive 24-hour urine collections on days 13, 14, and 15 of each dietary period, and 1H NMR spectra were acquired on all samples. Pattern recognition analysis allowed differentiation of the characteristic metabolic signatures of the diets with creatine, carnitine, acetylcarnitine, and trimethylamine-N-oxide (TMAO) being elevated in the high-meat consumption period. Application of orthogonal projection to latent structure discriminant analysis (O-PLS-DA) allowed the low-meat diet and vegetarian diet signatures to be characterized, and p-hydroxyphenylacetate (a microbial mammalian cometabolite) was higher in the vegetarian than meat diet samples, signaling an alteration of the bacterial composition or metabolism in response to diet. This work shows the potential for the routine use of metabonomics in nutritional and epidemiological studies, in characterizing and predicting the metabolic effects and the influence of diet on human metabotypes.

Acetylcarnitine↗

A study of interlaboratory influence on column evaluation.

A liquid chromatography method for the characterization of base deactivated columns was investigated in a collaborative study involving six laboratories. This work was carried out on two chromatographic supports (Xterra RP 18 and Symmetry Shield). Different cooling systems, namely water bath and air oven, were tested and it was shown that column thermoregulation did not significantly influence chromatographic data. In order to control the mobile phase composition, the latter was prepared by weight rather than volume. Thanks to the injection of a set of selected neutral compounds, extra-column effects were evaluated in each of the participating laboratories. The results showed that chromatographic supports tested in different laboratories and following the same test protocol could be effectively compared.

Chromatography, High Pressure Liquid↗

Novel RPLC stationary phases for lipophilicity measurement: solvatochromic analysis of retention mechanisms for neutral and basic compounds.

An RPLC was developed to rapidly determine lipophilicity of neutral and basic compounds using three base deactivated RPLC stationary phases particularly designed for the analysis of basic compounds, namely, Supelcosil ABZ(+)Plus, Discovery RP Amide C16, and Zorbax Extend C18. The work consisted of three sets of experiments. In the first log kw values of neutral compounds were extrapolated using hydroorganic mobile phases at different compositions. Good correlation between log kw and log Poct indicated that the method was appropriate for these supports, without adding a silanol masking agent. In the second set of experiments, isocratic log k values of neutral and basic compounds were measured with three different mobile phases. The best estimation of lipophilicity was obtained for neutral and basic compounds when the secondary interactions were strongly reduced (i. e., when basic compounds were under their neutral form). In the third set of experiments, isocratic retention factors of basic compounds (in their neutral form) were measured with a high-pH mobile phase, on a chemically stable support (Zorbax Extend C18). Under these chromatographic conditions, correlation between the isocratic retention factors and log Poct (log D10.5) for basic compounds was similar to that for neutral compounds.

Chromatography, Liquid↗

Analysis of basic compounds at high pH values by reversed-phase liquid chromatography.

Reversed phase high performance liquid chromatography (RPLC) is currently the method of choice for the analysis of basic compounds. However, with traditional silica materials, secondary interactions between the analyte and residual silanols produce peak tailing which can negatively affect resolution, sensitivity, and reproducibility. In order to reduce these secondary interactions, which comprise ion exchange, hydrogen bonding, and London forces interactions, chromatographic analyses can be carried out at low or high pH values where silanol groups and basic compounds are mostly uncharged. The chromatographic behaviour of a particular bidentate stationary phase, Zorbax Extend C18, was studied with a set of basic and neutral compounds. Thanks to a higher chemical stability than traditional silica based supports, analyses were carried out with a high pH mobile phase, which represents a good alternative to the acidic mobile phases generally used to reduce ion exchange interactions. The performance of this bidentate stationary phase was also compared with that of other supports and it was proved that it is advantageous to work with high pH mobile phases when analyzing basic compounds.

Chromatography, High Pressure Liquid↗