PubMed Health⌕ Search

Biomedical subjects

Clare Tempany

Publications and source records attributed to Clare Tempany.

10 recordsLinked to original sources

Magnetic resonance-guided interstitial therapy for vaginal recurrence of endometrial cancer.

PURPOSE: To evaluate the feasibility and to describe the acute toxicity of a real-time intraoperative magnetic resonance (MR)-image guided interstitial approach to treating vaginal recurrence of endometrial cancer. METHODS AND MATERIALS: From February 2004 to April 2005, 10 patients with recurrent endometrial cancer underwent MR-guided interstitial brachytherapy. Parameters evaluated included needle placement, dose-volume histograms (DVH), and complications. RESULTS: Magnetic resonance-image guidance resulted in accurate needle placement. Tumor DVH values included median volume, 47 cc; V100, 89%; V150, 61%; V200, 38%; D90, 71 Gy; and D100, 60 Gy. DVH of organs at risk resulted in a median D2cc of external beam and brachytherapy dose (% of brachytherapy prescription): bladder, 75Gy(3) (88%); rectum, 70Gy(3) (87%); and sigmoid, 56Gy(3) (41%). All patients experienced either a Grade 1 or 2 acute toxicity related to the radiation; only 1 patient had Grade 3 toxicity. No toxicities were attributable to the use of MR guidance. CONCLUSIONS: Real-time MR guidance during the insertion of interstitial needles reduces the likelihood of an inadvertent insertion of the needles into the bladder and the rectum. Three-dimensional dosimetry allows estimation of the dose to organs at risk. Toxicities are limited.

Aged↗

Neoadjuvant docetaxel before radical prostatectomy in patients with high-risk localized prostate cancer.

PURPOSE: To determine the clinical, pathologic, and molecular effects of neoadjuvant docetaxel chemotherapy in high-risk localized prostate cancer. EXPERIMENTAL DESIGN: Patients with biopsy Gleason scores of 8 to 10, serum prostate-specific antigen levels >20 ng/mL, and/or clinical stage T3 disease received weekly docetaxel (36 mg/m2) for 6 months, followed by radical prostatectomy, and were monitored with weekly visits, serum prostate-specific antigen measurements, and endorectal magnetic resonance imaging (MRI). Frozen tumor specimens were collected for microarray analysis. RESULTS: The 19 patients enrolled received 82% of the planned chemotherapy. Toxicity was mild to moderate; fatigue and taste disturbance were common. Prostate-specific antigen declines of >50% were seen in 11 of 19 patients (58%; 95% confidence interval, 33-80%) and endorectal MRI showed maximum tumor volume reduction of at least 25% in 13 of 19 patients (68%; 95% confidence interval, 47-85%) and at least 50% in 4 patients (21%; 95% confidence interval, 6-46%). Sixteen patients completed chemotherapy and had radical prostatectomy; none achieved pathologic complete response. Microarray analysis identified coordinate up-regulation of genes involved in androgen metabolism associated with docetaxel therapy. Specifically, RNA expression for genes that decrease cellular levels of bioactive androgens was coordinately increased in response to chemotherapy. CONCLUSIONS: Neoadjuvant docetaxel administered for 6 months before radical prostatectomy is feasible, well tolerated, and often results in prostate-specific antigen declines of >50% and decreased tumor volume on endorectal MRI. No pathologic complete responses were observed. Altered androgen metabolism may partially account for the noted declines in prostate-specific antigen and be a mechanism for chemotherapy resistance.

Adult↗

MR imaging-controlled focused ultrasound ablation: a noninvasive image-guided surgery.

The history of MR-guided FUS demonstrates the need for merging advanced therapy technology with advanced imaging. Without the ability of MR imaging to localize the tumor margins and without the temperature-sensitive imaging that provides the closed-loop control of energy deposition, this method is inadequate for most clinical applications. Given these limitations,high-intensity focused ultrasound initially appeared to have a narrow application area and was not able to compete with other surgical or ablation methods. Today, MR imaging-guided FUS has become a safe and effective means of performing probe-delivered thermal ablations and minimally invasive surgery. Moreover, it has the potential to replace treatments that use ionizing radiation such as radiosurgery and brachytherapy. Although the cost of integrating"big ticket" MR imaging systems with complex and expensive phased arrays is high, this expenditure will largely be offset by eliminating hospitalization and anesthesia and by reducing complications. In effect, an investment in this emerging technology will ultimately redound to the benefit of the health care delivery system and, most important, to the patient. The FUS system provides a safe, repeatable treatment approach for benign tumors (eg, uterine fibroid and breast fibroadenoma) that do not require an aggressive approach. MR-guided FUS can also be used for debulking cancerous tissue. It has already been tested as a breast cancer treatment; its application for other malignancies in the brain, liver, and prostate is under development. MR-guided FUS offers an attractive alternative to conventional surgery because it incorporates intraoperative MR imaging, which provides far more precise target definition than is possible with the surgeon's direct visualization of the lesion. MR-guided FUS is undeniably the most promising interventional MR imaging method in the field of image-guided therapy today. It is applicable not only in the thermal coagulative treatment of tumors but also in several other medical situations for which invasive surgery or radiation may not be treatment options. The use of FUS for treating vascular malformation or functional disorders of the brain is also exciting. It is uniquely applicable for image-guided therapy using targeted drug delivery methods and gene therapy. Further advances in this technology will no doubt improve energy deposition and reduce treatment times. In the near future, FUS will offer a viable alternative to conventional surgery and radiation therapy; in the longer-term, it may also enable a host of targeted treatment methods aimed at eradicating or arresting heretofore intractable diseases such as certain brain malignancies and forms of epilepsy.

Humans↗

Acute urinary retention after magnetic resonance image-guided prostate brachytherapy with and without neoadjuvant external beam radiotherapy.

OBJECTIVES: To evaluate the risk of acute urinary retention (AUR) and sequelae after urethra-sparing magnetic resonance imaging (MRI)-guided prostate brachytherapy. METHODS: Between 1997 and 2003, MRI-guided prostate brachytherapy was performed after external beam radiotherapy (n = 60) or as monotherapy (n = 188) following a diagnosis of low-risk prostate adenocarcinoma. The median prostate gland volume was 40 cm3 (range 16 to 184). Of the 248 patients, 88 (35%) had prostate gland volumes greater than 45 cm3. The median follow-up was 40 months. RESULTS: Of the 248 patients, 18 (7%) developed AUR. Of the 248 patients, 2% (3 of 160), 6% (3 of 49), 28% (8 of 29), and 40% (4 of 10) of patients experienced AUR if the prostate gland volume was less than 45, 45 to 60, 60 to 90, or greater than 90 cm(3), respectively (P <0.0001). Retention requiring intermittent self-catheterization resolved in one half of the patients by 2 weeks and had resolved in all patients by 6 weeks. At 1, 3, and 6 months after implantation, 100%, 57%, and 29% of patients who experienced AUR, respectively, used Flomax (P <0.0001). The mean Flomax dose used decreased from 0.9 mg at 1 month to 0.53 mg at 1 year. CONCLUSIONS: AUR after urethral-sparing MRI-guided prostate brachytherapy is volume dependent and is self-limited despite very large prostate gland volumes.

Acute Disease↗

Detection of fetal lactate with two-dimensional-localized proton magnetic resonance spectroscopy.

BACKGROUND: Antenatal surveillance is inefficient for accurately detecting fetal compromise. A noninvasive technique for assessing fetal metabolic status would be useful for clinical management. CASE: Fetal magnetic resonance spectroscopy was performed at 20 weeks in a pregnancy complicated by severe intrauterine growth restriction to determine if lactate, a metabolite associated with fetal hypoxia, was present. Two-dimensional, single-slice proton magnetic resonance spectroscopy was carried out at 1.5 T using a volume-selective, double-spin echo technique. Lactate was detected in fetal back muscle. Fetal death occurred the next day. CONCLUSIONS: Although this initial report is purely experimental, further development of this technique may prove to be a valuable noninvasive tool in the management of suspected fetal hypoxia.

Adult↗

MRI guidance of focused ultrasound therapy of uterine fibroids: early results.

OBJECTIVE: The purpose of this study was to explore our hypothesis that MRI-guided focused ultrasound therapy for the treatment of uterine fibroids will lead to a significant reduction in symptoms and improvement in quality of life. We describe focused ultrasound therapy applications and the method for monitoring the thermal energy deposited in the fibroids, including the MRI parameters required, in a prospective review of 108 treatments. MATERIALS AND METHODS: Patients presenting with symptomatic uterine fibroids who attained a minimal symptom severity score and who would otherwise have been offered a hysterectomy were recruited. Thermal lesions were created within target fibroids using an MRI-guided focused ultrasound therapy system. The developing lesion was monitored using real-time MR thermometry, which was used to assess treatment outcome in real time to change treatment parameters and achieve the desired outcome. Fibroid volume, fibroid symptoms, and quality-of-life scores were measured before treatment and 6 months after treatment. Adverse events were actively monitored and recorded. RESULTS: In this study, 79.3% of women who had been treated reported a significant improvement in their uterine fibroid symptoms on follow-up health-related quality-of-life questionnaires, which supports our hypothesis. The mean reduction in fibroid volume at 6 months was 13.5%, but nonenhancing volume (mean, 51 cm(3)) remained within the treated fibroid at 6 months. CONCLUSION: This early description of MRI-guided focused ultrasound therapy treatment of fibroids includes follow-up data and shows that, although the volume reduction is moderate, it correlates with treatment volume and the symptomatic response to this treatment is encouraging.

Adult↗

Workflow modeling and analysis of computer guided prostate brachytherapy under MR imaging control.

We demonstrate that classical Business Process Reengineering (BPR) methods can be successfully applied to Computer Aided Surgery while increasing safety and efficiency of the overall procedure through an integrated Workflow Management System. Computer guided Prostate Brachytherapy, as a sophisticated treatment by an interdisciplinary team, is perfectly suited to apply our method. Detailed suggestions for improvement of the whole procedure could be derived by our modified BPR method.

Brachytherapy↗

A unified variational approach to denoising and bias correction in MR.

We propose a novel bias correction method for magnetic resonance (MR) imaging that uses complementary body coil and surface coil images. The former are spatially homogeneous but have low signal intensity; the latter provide excellent signal response but have large bias fields. We present a variational framework where we optimize an energy functional to estimate the bias field and the underlying image using both observed images. The energy functional contains smoothness-enforcing regularization for both the image and the bias field. We present extensions of our basic framework to a variety of imaging protocols. We solve the optimization problem using a computationally efficient numerical algorithm based on coordinate descent, preconditioned conjugate gradient, half-quadratic regularization, and multigrid techniques. We show qualitative and quantitative results demonstrating the effectiveness of the proposed method in producing debiased and denoised MR images.

Algorithms↗

A shape-based approach to the segmentation of medical imagery using level sets.

We propose a shape-based approach to curve evolution for the segmentation of medical images containing known object types. In particular, motivated by the work of Leventon, Grimson, and Faugeras, we derive a parametric model for an implicit representation of the segmenting curve by applying principal component analysis to a collection of signed distance representations of the training data. The parameters of this representation are then manipulated to minimize an objective function for segmentation. The resulting algorithm is able to handle multidimensional data, can deal with topological changes of the curve, is robust to noise and initial contour placements, and is computationally efficient. At the same time, it avoids the need for point correspondences during the training phase of the algorithm. We demonstrate this technique by applying it to two medical applications; two-dimensional segmentation of cardiac magnetic resonance imaging (MRI) and three-dimensional segmentation of prostate MRI.

Algorithms↗

Vaginal metastasis from uterine leiomyosarcoma. Magnetic resonance imaging features with pathological correlation.

Vaginal metastases, though more frequent than primary vaginal tumors, are rare. Except for isolated reports of metastatic disease arising from extragenital organs, the vagina is typically a site for metastatic disease from genitourinary tract sites, especially cervix, endometrium, and kidney. We present herein a case of a 68-year-old woman presenting with a vaginal metastasis as the first manifestation of a uterine leiomyosarcoma. The magnetic resonance imaging features are described and correlated with the pathological findings. To the best of our knowledge, this is the first case of vaginal metastasis from uterine leiomyosarcoma described in the literature.

Aged↗