PubMed Health⌕ Search

Biomedical subjects

Claude F Burgoyne

Publications and source records attributed to Claude F Burgoyne.

10 recordsLinked to original sources

Segmentation of trabeculated structures using an anisotropic Markov random field: application to the study of the optic nerve head in glaucoma.

The study of the architecture of the optic nerve head (ONH) may provide valuable information about the development and progression of glaucoma. To this end, we have generated three-dimensional datasets from monkey eyes under controlled intraocular pressure (IOP). Segmentation of the connective tissues in this area is crucial to obtain an accurate measurement of geometrical parameters and to build mechanical models. However, this segmentation is made difficult by the complicated geometry and the artifacts introduced in the dataset building process. We present a novel segmentation algorithm, based on expectation-maximization, which incorporates an anisotropic Markov random field (MRF) to introduce prior knowledge about the geometry of the structure. The structure tensor is used to characterize the predominant structure direction and the spatial coherence at each point. The algorithm, which has been validated on an artificial validation dataset that mimics our ONH datasets, shows significant improvement over an isotropic MRF. Results on the real datasets demonstrate the ability of the new algorithm to obtain accurate, spatially consistent segmentations of this structure.

Algorithms↗

The optic nerve head as a biomechanical structure: a new paradigm for understanding the role of IOP-related stress and strain in the pathophysiology of glaucomatous optic nerve head damage.

We propose here a conceptual framework for understanding the optic nerve head (ONH) as a biomechanical structure. Basic principles of biomechanical engineering are used to propose a central role for intraocular pressure (IOP)-related stress and strain in the physiology of ONH aging and the pathophysiology of glaucomatous damage. Our paradigm suggests that IOP-related stress and strain (1) are substantial within the load-bearing connective tissues of the ONH even at low levels of IOP and (2) underlie both ONH aging and the two central pathophysiologies of glaucomatous damage--mechanical failure of the connective tissues of the lamina cribrosa, scleral canal wall, and peripapillary sclera, and axonal compromise within the lamina cribrosa by a variety of mechanisms. Modeling the ONH as a biomechanical structure generates a group of testable hypotheses regarding the central mechanisms of glaucomatous damage and provides a logic for classifying the principal components of the susceptibility of an individual ONH to a given level of IOP.

Animals↗

Viscoelastic material properties of the peripapillary sclera in normal and early-glaucoma monkey eyes.

PURPOSE: To test the hypothesis that changes in the viscoelastic material properties of peripapillary sclera are present within monkey eyes at the onset of early experimental glaucoma detected by confocal scanning laser tomography (CSLT). METHODS: Short-term (3-9 weeks), moderate (< or =44 mm Hg) intraocular pressure (IOP) elevation was induced in one eye of each of eight male monkeys by lasering the trabecular meshwork. This procedure generated early experimental glaucoma, defined as the onset of CSLT-detected optic nerve head (ONH) surface change, in the treated eye. Scleral tensile specimens from the superior and inferior quadrants of the eight early-glaucoma eyes were subjected to uniaxial stress relaxation and tensile tests to failure and the results compared with similar data obtained in a previous study of 12 normal (nonglaucomatous) eyes. Linear viscoelastic theory was used to characterize viscoelastic material property parameters for each specimen. Differences in each parameter due to quadrant and treatment were assessed by analysis of variance (ANOVA). RESULTS: Peripapillary sclera from the early-glaucoma eyes exhibited an equilibrium modulus (7.46 +/- 1.58 MPa) that was significantly greater than that measured in normal eyes (4.94 +/- 1.22 MPa; mean +/- 95% confidence interval, P < 0.01, ANOVA). Quadrant differences were not significant for the viscoelastic parameters within each treatment group. CONCLUSIONS: The long-term viscoelastic material properties of monkey peripapillary sclera are altered by exposure to moderate, short-term, chronic IOP elevations and these alterations are present at the onset of CSLT-detected glaucomatous damage to the ONH. Damage to and/or remodeling of the extracellular matrix of these tissues may underlie these changes in scleral material properties.

Animals↗

Idiopathic bilateral optic atrophy in the rhesus macaque.

PURPOSE: To document the existence of idiopathic bilateral optic atrophy (BOA) in rhesus macaque monkeys and to characterize the structural and functional consequences of this condition. METHODS: In vivo assessment of retinal and optic nerve structure included fundus biomicroscopy and stereophotography. Functional analyses included transient pattern-reversal electroretinography (PERG) and full-field flash ERG, with both white flashes while dark adapted and red flashes on a blue background used to assess the photopic negative response (PhNR). Also measured were visual evoked cortical potentials (VEPs) and multifocal (mf)ERGs, with both a standard fast and slowed (7F) stimulation sequence. Post mortem histologic evaluation was performed on a subset of five animals with BOA and compared with data from 22 healthy normal animals. Blood tests, including vitamin E, B(12), folate, lead, and complete blood cell count with differential were obtained on the four animals that remained alive. RESULTS: Animals with BOA showed temporal pallor of the optic nerve head and thinning of the retinal nerve fiber layer (RNFL) between the temporal vascular arcades (i.e., of the papillomacular bundle). Severity of optic atrophy and RNFL loss varied between animals from mild to severe, but was similar in the two eyes of each animal. Functional changes included greater loss of the PERG N95, compared with the P50 component and substantial reduction of mfERG high-frequency components. The mfERG low-frequency components were slightly larger than normal. None of the full-field flash ERG amplitudes (a-wave, b-wave, oscillatory potentials, or PhNR) was significantly different from normal. There were no consistent abnormalities found in the results of any blood test. Histologic findings included axonal loss and gliosis limited to the temporal optic nerve, reduction of nuclei within the retinal ganglion cell layer, and thinning of the temporal retinal RNFL. CONCLUSIONS: The existence of BOA in nonhuman primates warrants caution on the part of investigators who use these animals in experimental models of ophthalmic disease.

Animals↗

Three-dimensional reconstruction of normal and early glaucoma monkey optic nerve head connective tissues.

PURPOSE: To introduce high-resolution, digital three-dimensional (3-D) reconstruction of the connective tissues of the optic nerve head (ONH). METHODS: Trephinated ONH and peripapillary sclera from both eyes of three monkeys with early glaucoma (EG; one eye normal, one eye given laser-induced EG) were embedded in paraffin and serial sectioned at 3-mum thickness from the vitreous surface through the orbital optic nerve, with the embedded tissue block face stained and imaged after each cut. Each image was aligned, and then the scleral canal wall, sclera, border tissue of Elschnig, Bruch's membrane, lamina cribrosa, optic nerve septa, pial sheath, and vasculature were delineated as unique objects. Delineated images were stacked, color mapped, and volume rendered and then serial sagittal and transverse digital sections of the resultant voxel geometries were viewed and measured. RESULTS: Substantial differences in the 3-D architecture of the peripapillary sclera, scleral canal wall, and lamina cribrosa were present among the three normal eyes. All three EG eyes displayed permanent posterior deformation of the central lamina cribrosa, as well as expansion of the anterior and posterior neural canal openings in comparison with their respective contralateral normal control eyes. Peripherally, whereas laminar deformation was greatest inferiorly or superiorly in all three EG eyes, statistically significant deformation was present in all four quadrants of all three eyes. CONCLUSIONS: High-resolution, digital 3-D reconstructions of the load-bearing connective tissues of the monkey ONH confirm that the ONH connective tissues are profoundly altered at the onset of detectable ONH surface change in experimental glaucoma.

Animals↗

Viscoelastic characterization of peripapillary sclera: material properties by quadrant in rabbit and monkey eyes.

In this report we characterize the viscoelastic material properties of peripapillary sclera from the four quadrants surrounding the optic nerve head in both rabbit and monkey eyes. Scleral tensile specimens harvested from each quadrant were subjected to uniaxial stress relaxation and tensile ramp to failure tests. Linear viscoelastic theory, coupled with a spectral reduced relaxation function, was employed to characterize the viscoelastic properties of the tissues. We detected no differences in the stress-strain curves of specimens from the four quadrants surrounding the optic nerve head (ONH) below a strain of 4 percent in either the rabbit or monkey. While the peripapillary sclera from monkey eyes is significantly stiffer (both instantaneously and in equilibrium) and relaxes more slowly than that from rabbits, we detected no differences in the viscoelastic material properties (tested at strains of 0-1 percent) of sclera from the four quadrants surrounding the ONH within either species group.

Animals↗

Deformation of the lamina cribrosa and anterior scleral canal wall in early experimental glaucoma.

PURPOSE: To test the hypothesis that pathophysiologic deformation of the lamina cribrosa and anterior scleral canal wall underlies the onset of confocal scanning laser tomography (CSLT)-detected optic nerve head (ONH) surface change in early experimental glaucoma. METHODS: Both eyes of four normal (two normal eyes) monkeys and four with early glaucoma (one eye with laser-induced IOP elevation, observed until the onset of CSLT-detected ONH surface change) were enucleated immediately after death and immersion fixed at IOP 0 mm Hg. In an additional four normal monkeys and five with early glaucoma, both eyes were cannulated, and IOP set to 10 mm Hg in one normal eye and either 30 or 45 mm Hg in the other (normal or early-glaucoma) eye. After 15 to 80 minutes of acute IOP elevation, these nine monkeys were perfusion-fixed. Within images of serial sagittal sections of the ONH tissues in all 17 monkeys, anterior lamina cribrosa position, laminar thickness, and scleral canal diameter were measured. For each parameter, differences between the two eyes of each monkey and between treatment groups were assessed by ANOVA. RESULTS: Within the eyes of the eight monkeys with IOP 0 mm Hg, the lamina cribrosa was posteriorly displaced and thicker and the scleral canal was enlarged at Bruch's membrane and at the anterior laminar insertion in the early-glaucoma eyes compared with the contralateral normal eyes (plastic deformation). Within the high-IOP normal eyes, the lamina cribrosa was posteriorly displaced compared with that in the low-IOP normal eyes, but there were no significant differences in laminar thickness or scleral canal diameter (normal compliance). Within the high-IOP early-glaucoma eyes, the lamina cribrosa was posteriorly displaced and thicker and the scleral canal enlarged, compared with both low-IOP normal eyes and high-IOP normal eyes (hypercompliant deformation). Differences in laminar position between the high-IOP early-glaucoma eyes and the contralateral low-IOP normal eyes (hypercompliant plus plastic deformation) were more than eight times greater than the differences between the high-IOP normal eyes and the contralateral low-IOP normal eyes (normal compliance). CONCLUSIONS: Both plastic (permanent) and hypercompliant deformation of the lamina cribrosa and anterior scleral canal wall are present in young adult monkey eyes with early experimental glaucoma. These findings suggest that damage to the ONH connective tissues occurs early in the monkey model of experimental glaucoma.

Animals↗

Clinician change detection viewing longitudinal stereophotographs compared to confocal scanning laser tomography in the LSU Experimental Glaucoma (LEG) Study.

PURPOSE: To compare optic nerve head (ONH) surface change detection by confocal scanning laser tomography (CSLT) within the LSU Experimental Glaucoma (LEG) study to expert clinicians viewing the LEG stereophotographs. DESIGN: Experimental study. PARTICIPANTS: Four fellowship-trained glaucoma specialists. METHODS: In the LEG study, six 15 CSLT images (TopSS, Laser Diagnostics Technologies, San Diego, CA) and four 2x optic disc stereophotographs were obtained from both eyes of 12 monkeys on 3 separate days and then every 2 weeks after laser to one eye (study eye) to elevate intraocular pressure. ONH surface change detection within the CSLT images is described in our companion report. In this report, the preliminary study compared change detection by the CSLT multivariate strategy with that of a single clinician viewing stereophotograph pairs on three separate occasions as the "gold standard." The main study compared change detection by three additional clinicians viewing a subset of LEG stereophotograph pairs on three separate occasions with that of the CSLT multivariate strategy as the "gold standard." Clinician change detection was assessed for partial (two of three occasions) or complete (three of three occasions) agreement. Three comparison groups within the main study are emphasized: 44 group A comparisons assessed false-positive change detection (specificity); 38 group B comparisons assessed change detection within 38 instances (11 onset and 27 progression events) of CSLT-detected study eye change; and 30 group C comparisons assessed change detection within 30 instances in which the CSLT failed to detect change in study eyes. MAIN OUTCOME MEASURES: Clinician change detection within each comparison with either partial or complete agreement. RESULTS: Within the main study, intrareading (-.29 to 0.67) and interreading (0.24--0.56) session agreement for each clinician was slight to moderate by kappa test. Good specificity (less than 10% false-positive change detection) was achieved within the 44 group A comparisons by two of the three clinicians, but only when the more stringent criterion (change detection on three of three occasions) was applied. Of the 38 group B comparisons (in which the CSLT detected change), the two clinicians who achieved good specificity in group A failed to detect change in 25 and 16 instances, respectively, using the more stringent (three of three) criterion. Similarly, of the 30 group C comparisons (in which the CSLT failed to detect change), these two clinicians detected change in three and seven instances, respectively, but in only one comparison did they both detect change. CONCLUSIONS: This study provides the first direct evidence that an existing CSLT may reasonably meet or exceed the ONH surface change detection performance of fellowship-trained glaucoma specialists in at least those eyes with good CSLT reproducibility.

Animals↗

Change detection in regional and volumetric disc parameters using longitudinal confocal scanning laser tomography.

PURPOSE: To develop a clinically specific strategy for optic nerve head (ONH) surface change detection within longitudinally acquired confocal scanning laser tomographic (CSLT) images. DESIGN: Experimental study. PARTICIPANTS AND/OR CONTROLS: Twelve monkeys, each with one glaucomatous and one contralateral normal eye. MAIN OUTCOME MEASURES: Detection of ONH surface change within the CSLT images of each monkey's glaucomatous eye. METHODS: Six 10 and six 15 CSLT images and four stereo optic disc photographs were obtained from both eyes of 12 monkeys on 3 separate days (imaging sessions) and then every 2 weeks after laser to one eye (study eye) to elevate intraocular pressure. For each set of 10 and 15 images per eye (and for each of the 7-25 imaging sessions per monkey), 37 CSLT parameters were calculated. Univariate change required an individual parameter to change in excess of its analysis of variance-determined minimum detectable change (MDC) value. Multivariate change required groups of three parameters, considered together, to demonstrate significant change as determined by a multivariate analysis of variance. The rate of false-positive change detection for each individual parameter and for a group of three-parameter combinations was determined using both a one-in-a-row strategy (change at a single session) and a two-in-a-row strategy (change at two successive sessions) within the postlaser images of the 12 unchanging contralateral normal eyes. Change detection within the study eye images was then assessed for only those individual parameters and three-parameter combinations that were clinically specific (i.e., showed less than 10% false-positive change detection in the normal eyes). RESULTS: A total of 36 prelaser (three per monkey) imaging sessions and 158 postlaser (4-22/monkey) imaging sessions was performed. Clinically specific change detection (low rate of false positives) was achieved only with the two-in-a-row strategy. Overall, multivariate ONH surface change detection performed best; the best-performing three-parameter combination detected only 8 change events (4 onset and 4 progression) in 139 imaging sessions within the postlaser imaging sessions of the contralateral normal eyes and a total of 47 change events (11 onset and 36 progression) within the postlaser imaging sessions of the 12 study eyes. Counterintuitive (anterior) change occurred in most parameters within the late postlaser imaging sessions of the study eyes followed to end-stage damage. CONCLUSIONS: Clinically specific detection of the onset and progression of glaucomatous ONH surface change is possible within longitudinally acquired CSLT images.

Animals↗

Peripapillary scleral thickness in perfusion-fixed normal monkey eyes.

PURPOSE: To characterize the thickness of the peripapillary sclera in perfusion-fixed normal monkey eyes so as to build accurate computational models of intraocular pressure (IOP)-related stress and strain within these tissues. METHODS: Nine rhesus monkeys were perfusion fixed, each with one normal eye set to an IOP of 10 mm Hg by manometer. A 6-mm-diameter specimen containing the optic nerve head and peripapillary sclera was trephined from each scleral shell and cut into 4-microm serial sagittal sections across the scleral canal opening, either horizontally (four eyes) or vertically (five eyes). The thickness of the peripapillary sclera was measured on every 24th section at 100-microm intervals from the posterior scleral canal opening (PSCO) to the peripheral edge of the specimen. The data were pooled by quadrant (superior, inferior, nasal, and temporal), regions within each quadrant, and distance from the PSCO, overall and for individual eyes, and subjected to analysis of variance. RESULTS: In terms of distance from the PSCO, the peripapillary sclera was thinnest nearest the PSCO (201 microm, nasal; 201 microm, temporal; 240 microm, inferior; 249 microm, superior), thickened progressively to a maximum in the midperiphery approximately 600 to 1000 microm from the PSCO (326 microm, nasal; 415 microm, superior; 420 microm, temporal; 422 microm, inferior), and thinned again peripherally in all quadrants. The peripapillary sclera was thinner in the nasal quadrant when compared with the other quadrants superiorly, inferiorly, and temporally (central region means of 291 microm, nasal; 369 microm, superior; 372 microm, inferior; and 369 microm, temporal; P < 0.0001). CONCLUSIONS: In the normal monkey eye, peripapillary scleral thickness varies significantly with distance from the posterior scleral canal opening and is thinner in the nasal quadrant than in the other quadrants. These differences are substantial and are likely to affect the magnitude of IOP-related stress and strain within these tissues for a given level of IOP.

Animals↗