PubMed Health⌕ Search

Biomedical subjects

Claudia Alcaraz Zini

Publications and source records attributed to Claudia Alcaraz Zini.

4 recordsLinked to original sources

Detector technologies for comprehensive two-dimensional gas chromatography.

The detector is an integral and important part of any chromatographic system. The chromatographic peak profiles (i.e. peak separation) should, ideally, be unaffected by the detector--it should only provide the sensing capacity required at the end of a column separation process. The relatively new technique of comprehensive 2-D GC (GC x GC) extends the performance of GC manyfold, but comes at a price--existing GC systems may not be adequately designed with the requirements of GC x GC in mind. This is primarily the need for precise measurement of very fast peaks entering the detector (e.g. as fast as 50 ms basewidth in some instances). The capacity of the detector to closely track a rapidly changing chromatographic peak profile depends on a number of factors, such as design of flow paths and make-up gas introduction, type of detector response mechanism, and the chemistry of the response. These factors are discussed here as a means to appreciate the technical demands of detection in GC x GC. The MS detector will not be included in this review.

Chromatography, Gas↗

Applications of comprehensive two-dimensional gas chromatography to the characterization of petrochemical and related samples.

This article discusses the application of comprehensive two-dimensional gas chromatography (GC x GC) to samples derived from petrochemicals. The use of GC x GC for characterization of petroleum and petroleum derivatives, through group type analysis, such as benzene, toluene, ethylbenzene, xylenes (BTEX), total aromatic hydrocarbons, polyaromatic hydrocarbons, and heteroatomic sulfur-, oxygen-, and nitrogen-containing compounds is presented. The capability of GC x GC to provide additional chemical-specific information regarding petroleum-processing steps, such as linear alkanes dehydrogenation, Fischer-Tropsch process, hydrogenation and oligomerization, is also described. In addition, GC x GC analyses of petrochemical biomarkers and environmental petrochemical-derived pollutants are reported. The role of comparison of samples through use of simple fingerprint approaches is highlighted.

Biomarkers↗

Optimization of the sonication extraction method of Hibiscus tiliaceus L. flowers.

The influence of several experimental parameters on the ultrasonic extraction of Hibiscus tiliaceus L. flowers were investigated: extraction time, solvent polarity, sample amount, solvent volume and sample particle size. It was concluded that the most influential variables were extraction time and solvent polarity. The optimized procedure employed 5 g of ground flowers, 150 mL of methanol and 140 min of extraction. The extracts were fractionated using preparative silica columns and the resulting fractions were analyzed by GC/MS. Some saturated hydrocarbons, fatty acids, fatty acid methyl esters, phytosterols, and vitamin E were identified in the plant extracts.

Flowers↗

Quantitative analysis of benzene, toluene, and xylenes in urine by means of headspace solid-phase microextraction.

A simple method for benzene, toluene, and xylenes (BTX) quantitative analyses in human urine was developed, using headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled to mass spectrometry detection in the single ion monitoring mode. The developed method is solventless, non-invasive, requires small volume of sample (1 ml), shows high selectivity, sensitivity, repeatability, and linearity (correlation coefficients >0.998), providing a useful alternative to assess human exposure to BTX compounds due to occupational reasons or eventual exposure to organic solvents. Detection limit varies from 0.28 to 0.5 ppb (v/v).

Benzene↗