PubMed Health⌕ Search

Biomedical subjects

Claudio Lamberti

Publications and source records attributed to Claudio Lamberti.

7 recordsLinked to original sources

Quantification of regional left ventricular wall motion from real-time 3-dimensional echocardiography in patients with poor acoustic windows: effects of contrast enhancement tested against cardiac magnetic resonance.

OBJECTIVE: Regional left ventricular function can be assessed by real-time 3-dimensional echocardiography (RT3DE) in patients with good image quality. Our goals were to: (1) test the feasibility of RT3DE quantification of regional wall motion (RWM) in patients with poor acoustic windows who require contrast for endocardial visualization; and (2) validate these measurements against cardiac magnetic resonance (CMR) reference. METHODS: RT3DE datasets and CMR images were obtained in 24 patients. In 16 of 24 patients with suboptimal endocardial definition, RT3DE imaging was repeated with intravenous contrast and triggering at end systole and end diastole. RT3DE datasets were analyzed using custom software designed to semiautomatically detect and segment the endocardial surface and calculate RWM values. CMR images were analyzed using commercial software to obtain reference values for RWM. RESULTS: In 8 of 24 patients with good endocardial definition, RT3DE values of RWM correlated well with CMR (r = 0.73) with a small bias (-1.0 mm). In the remaining 16 patients, analysis of nonenhanced RT3DE datasets yielded lower correlation with CMR (r = 0.61) and a slightly greater bias (-1.5 mm). The agreement with CMR improved significantly (r = 0.76, bias -1.1 mm) with contrast enhancement. CONCLUSIONS: The agreement between RT3DE and CMR values of RWM is directly related to RT3DE image quality. In patients with poor acoustic windows, dual-triggered contrast enhancement improves the accuracy of RWM quantification to a level similar to that noted in patients with good images without contrast.

Computer Systems↗

Mathematical modeling and numerical simulation in maxillo-facial virtual surgery (VISU).

Computer-based surgery simulation is a rapidly emerging and increasingly important area of research that combines a number of disciplines for the common purpose of improving healthcare. The objective of this paper is to provide a virtual surgery (VISU) tool for accurately planning the aesthetic impact of hard and soft tissue movements in dento-skeletal malocclusions. The approach proposed here allows direct interaction with a completely three-dimensional (3-D) computed tomography (CT) model of a solid, highly detailed structure of the head to obtain a realistic prediction of soft tissue behavior. We studied 25 patients who had facial malformations pre- and postoperatively with 3-D hard and soft tissue CT studies, and maxillary or mandibular osteotomies were simulated. The postoperative 3-D CT and facial outcomes were compared with the simulations. In 80% of the cases studied, the simulation-predicted changes, when compared with the clinical outcomes, were within the tolerance level (2 mm) established by maxillo-facial surgeons.

Adolescent↗

Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images.

BACKGROUND: Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. METHODS AND RESULTS: RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)-time and wall motion (WM)-time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98; y=0.99x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (+/-20 mL). WM correlated highly only in basal and midventricular segments (r=0.88; y=0.85x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. CONCLUSIONS: Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

Adult↗

Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models.

PURPOSE: The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. METHODS: Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. RESULTS: VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and -9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). CONCLUSION: VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.

Cardiac Volume↗

Maximum likelihood segmentation of ultrasound images with Rayleigh distribution.

This study presents a geometric model and a computational algorithm for segmentation of ultrasound images. A partial differential equation (PDE)-based flow is designed in order to achieve a maximum likelihood segmentation of the target in the scene. The flow is derived as the steepest descent of an energy functional taking into account the density probability distribution of the gray levels of the image as well as smoothness constraints. To model gray level behavior of ultrasound images, the classic Rayleigh probability distribution is considered. The steady state of the flow presents a maximum likelihood segmentation of the target. A finite difference approximation of the flow is derived, and numerical experiments are provided. Results are presented on ultrasound medical images as fetal echography and echocardiography.

Algorithms↗

Evolutionary partial differential equations for biomedical image processing.

We are presenting here a model for processing space-time image sequences and applying them to 3D echo-cardiography. The non-linear evolutionary equations filter the sequence with keeping space-time coherent structures. They have been developed using ideas of regularized Perona-Malik an-isotropic diffusion and geometrical diffusion of mean curvature flow type (Malladi-Sethian), combined with Galilean invariant movie multi-scale analysis of Alvarez et al. A discretization of space-time filtering equations by means of finite volume method is discussed in detail. Computational results in processing of 3D echo-cardiographic sequences obtained by rotational acquisition technique and by real-time 3D echo volumetrics acquisition technique are presented. Quantitative error estimation is also provided.

Algorithms↗

Left ventricular volume estimation for real-time three-dimensional echocardiography.

The application of level set techniques to echocardiographic data is presented. This method allows semiautomatic segmentation of heart chambers, which regularizes the shapes and improves edge fidelity, especially in the presence of gaps, as is common in ultrasound data. The task of the study was to reconstruct left ventricular shape and to evaluate left ventricular volume. Data were acquired with a real-time three-dimensional (3-D) echocardiographic system. The method was applied directly in the three-dimensional domain and was based on a geometric-driven scheme. The numerical scheme for solving the proposed partial differential equation is borrowed from numerical methods for conservation law. Results refer to in vitro and human in vivo acquired 3-D + time echocardiographic data. Quantitative validation was performed on in vitro balloon phantoms. Clinical application of this segmentation technique is reported for 20 patient cases providing measures of left ventricular volumes and ejection fraction.

Echocardiography, Three-Dimensional↗