PubMed Health⌕ Search

Biomedical subjects

Claus D Claussen

Publications and source records attributed to Claus D Claussen.

At least 73 records · Page 4Linked to original sources

Standardized assessment of whole body adipose tissue topography by MRI.

PURPOSE: To assess standardized whole body adipose tissue topography in a cohort of subjects at an increased risk for type 2 diabetes and to compare fat distribution in subgroups regarding anthropometric (age, body mass index [BMI]) and metabolic parameters (insulin sensitivity). MATERIALS AND METHODS: A total of 80 volunteers (40 females, 40 males) underwent T1-weighted MR imaging of the entire body. Standardized adipose tissue (AT) profiles were calculated considering the different body structure of the participants. The measured data were interpolated to a defined number of sampling points enabling a direct comparison of the profiles independent on body structure. Resulting mean profiles and region-dependent standard deviations of four age groups and three BMI-groups were compared for females and males. Correlations between insulin sensitivity and body fat distribution were analyzed. RESULTS: Reliable adipose tissue profiles could be obtained from all volunteers. In BMI-matched subgroups, females show significant higher AT and subcutaneous abdominal AT (P < 0.05 both), but lower visceral AT (P < 0.01) compared to the males. Furthermore, visceral AT increases with age, as shown in the matched age groups. In both gender groups, insulin-resistant subjects are characterized by higher visceral adipose tissue (VAT) compared to insulin-sensitive subjects. In addition, profiles of insulin-resistant subjects show more AT in the shoulder/neck region but less AT in the upper extremities. CONCLUSION: Standardized assessment of whole body AT profiles based on T1-weighted MRI provides a reliable basis for interindividual comparison of the body fat distribution and allows a fast and reliable quantification of total body adipose tissue and the distribution of different AT components as subcutaneous and visceral fat in different body regions. Differences in standardized profiles might enable an early identification of people at risk of metabolic disorders, as not only the amount but also the distribution of AT is expected to play an essential role in the pathogenesis of metabolic diseases.

Adipose Tissue↗

Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience.

PURPOSE: To demonstrate the feasibility of detecting atherosclerotic vascular disease using an innovative magnetic resonance angiography (MRA) protocol in combination with a dedicated whole-body MR scanner with new surface coil technology. MATERIALS AND METHODS: A total of 10 volunteers and eight patients with peripheral arterial occlusive disease (PAOD) were examined at 1.5 T. Conventional digital subtraction angiography (DSA) of the symptomatic region was available as a reference standard in all eight patients. Depending on subjects' size, four to five three-dimensional data sets were acquired using an adapted injection protocol. Images were assessed independently by two readers for vascular pathology. Additionally, signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were measured. RESULTS: Whole-body MRA yielded excellent sensitivity and specificity of more than 95% for both readers with high interobserver agreement (k = 0.93). Surface coil signal reception rendered a high SNR (mean 151.28 +/- 54.04) and CNR (mean 120.75 +/- 46.47). Despite lower SNR and CNR of the cranial and cervical vessels, a two-step injection protocol exhibited less venous superposition and therefore proved to be superior compared to single-bolus injection. CONCLUSION: Our approach provides accurate noninvasive high-resolution imaging of systemic atherosclerotic disease, covering the arterial vasculature from intracranial arteries to distal runoff vessels. The recently introduced MR scanner and coil technology is feasible to significantly increase the performance of whole-body MRA.

Adult↗

Evaluation of cardiac function and myocardial viability with 16- and 64-slice multidetector computed tomography.

Retrospectively ECG-gated MDCT shows a high correlation and acceptable agreement of left-ventricular functional parameters compared to MR imaging. Thus, in addition to the non-invasive evaluation of coronary arteries, further important additional information of left-ventricular functional parameters with clinical and prognostic relevance can be achieved by one single MDCT examination. For assessment of myocardial viability, low-dose CT late enhancement scanning is feasible, and preliminary results look promising. CT late enhancement adds valuable diagnostic information on the haemodynamical significance of coronary stenoses or prior to interventional procedures.

Animals↗

Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography.

OBJECTIVE: The goal of this study was to establish the feasibility of a low-dose whole-body multidetector row-CT (MDCT) protocol in the diagnosis of multiple myeloma (MM), as an alternative to conventional X-ray imaging, which is currently still state-of-the-art in these patients, with emphasis on the comparison of image resolution on axial and multiplanar reformatted (MPR) scans and reduction of radiation dose. MATERIAL AND METHODS: 100 patients with known MM, or monoclonal gammopathy of unknown significance (MGUS) underwent unenhanced whole-body MDCT on a 16-slice scanner in a randomised fashion, using a 16 x 1.5 mm collimation and four different energy parameters (40, 50, 60 and 70 mAs). Three different reconstruction algorithms were used in every patient (B40f, B50f and B60f kernel). CT scans were reviewed independently by two radiologists, with regard to correct classification into one of the three known MM stages, and recognition of fracture risk. Thereafter, axial and MPR images were evaluated in consensus by both readers, with respect to image resolution. Diagnosis of osteolytic lesions was performed on the basis of axial and multiplanar reformatted images, whereas the assessment of spinal misalignment and fracture was done only on MPR images. The distribution of image resolution categories (very good, good, sufficient, insufficient for diagnosis) was evaluated depending on following parameters: current time product, patient's weight, bone density and reconstruction algorithm. The effective radiation dose was determined with the aid of an anthropomorphic Alderson Rando-Phantom, using a tube current time product of 40 mAs, and then extrapolating it on all current time products applied in this study on a commercially available software program WinDose (Institute of Medical Physics, Erlangen, Germany). RESULTS: In all 100 patients, image resolution was diagnostic, regardless of scanning parameters, enabling correct classification of multiple myeloma patients. Image quality of MPR images was either equal or inferior to correspondent axial images in the delineation of smaller lytic lesions, because of the use of non-isotropic voxel size. However, they proved accurate in diagnosing fracture and spine misalignment. A strong dependency of image resolution on bone density was observed, with reduced quality in patients with either diffuse skeleton infiltration or concurrent osteoporosis. Spatial resolution was also dependent on the reconstruction algorithm and energy level (mAs) used, as well as on patient's weight, but their influence was low within the given ranges. A middle-frequency reconstruction algorithm (B50f kernel) proved beneficial for all energy protocols. The interobserver agreement was excellent (kappa = 0.95) for classification of MM-patients. Effective radiation dose of MDCT calculated at a tube current time product of 40 mAs was 1.7-fold higher than the mean radiation dose of conventional X-ray (4.1 mSv versus 2.4 mSv). DISCUSSION: Our study shows that whole-body low-dose MDCT investigational protocols are appropriate for the diagnosis of lytic bone changes and for assessment of fracture risk in multiple myeloma patients, representing a serious alternative to current standards.

Aged↗

Assessment of minimally invasive direct coronary artery bypass grafting of the left internal thoracic artery by means of magnetic resonance imaging.

OBJECTIVES: We sought to evaluate graft patency, flow, and flow reserve in patients with minimally invasive direct coronary artery bypass surgery of internal thoracic artery grafts by a combined magnetic resonance protocol with a phase-contrast technique and magnetic resonance angiography. METHODS: At 1.5 T (Magnetom Sonata, Siemens), 30 symptomatic patients with 30 left internal thoracic artery grafts were examined 6 years after minimally invasive surgical intervention. Navigator-gated magnetic resonance angiography and contrast-enhanced FLASH-3D magnetic resonance angiography (0.2 mmol gadopentate-diethylene triamine pentetic acid [Gd-DTPA]/kg body weight) was used to assess bypass patency. Phase-contrast flow measurements with retrospective gating were performed in the internal thoracic artery grafts at rest and after stress induction with dipyridamole (0.57 mg/kg body weight). Graft patency was evaluated by means of multidetector computed tomography (Sensation 16, Siemens). RESULTS: Internal thoracic artery grafts were occluded in 5 of 30 patients. In 6 patients the anastomosis to the left anterior descending artery was highly stenotic (>70 % ) at multidetector computed tomography. In patients with regular grafts (multidetector computed tomography), a significant improvement of graft flow ( P < .001) and diastolic/systolic peak velocity ratio ( P < .001) after stress induction was detected. Magnetic resonance angiography combined with flow reserve measurements could differentiate between occluded-stenotic and regular minimally invasive direct coronary artery bypass grafts. CONCLUSIONS: Magnetic resonance imaging allows a combined assessment of bypass patency and flow with flow reserve in patients after the minimally invasive direct coronary artery bypass operation. The protocol of this study might be applicable for the evaluation of graft status in symptomatic patients after revascularization.

Aged↗

Radio frequency versus susceptibility effects of small conductive implants--a systematic MRI study on aneurysm clips at 1.5 and 3 T.

PURPOSE: Metallic implants cause enlarged artifacts in magnetic resonance (MR) images at higher magnetic fields, B0, due to their magnetic susceptibility. Interactions of conductive material with radio frequency (RF) pulses also change for higher field strengths, B0, due to the frequency dependence of resonance conditions. Systematic measurements on commercial aneurysm clips and simplified copper models were performed in order to investigate both phenomena at 1.5 and 3 T. MATERIALS AND METHODS: Six different commercial aneurysm clips made of titanium, straight copper wires and bent copper models were examined in Gd-DTPA-doped water. RF-related effects were measured by adapted 2D and 3D spin-echo sequences. For reliable differentiation from susceptibility-related effects, variable transmitter voltages were applied. In addition, RF-induced heating was controlled by an infrared (IR) camera. RESULTS: At 3 T, a significant RF-induced electric response could be demonstrated for the copper samples and more moderate for one of the commercial clips, dependent on the geometrical structure determining possible resonant RF coupling. Related RF effects could be distinguished from susceptibility artifacts: a signal enhancement at reduced transmitter voltages indicated locally amplified B1-field amplitudes. No significant heating effect could be measured by IR measurements. CONCLUSION: MR imaging was used to analyze possible RF-induced effects. At 3 T, resonant RF coupling even of small metallic implants has to be considered carefully. Despite a local enhancement of the RF amplitude, no significant RF-induced heating inside the surrounding fluid was found. A direct thermal endangering of patients seems to be unlikely, but extremely high B1-field amplitudes might occur adjacent to the metallic surface with potential nonthermal affection of tissue.

Artifacts↗

Fast whole-body assessment of metastatic disease using a novel magnetic resonance imaging system: initial experiences.

OBJECTIVE: The objective of this study was to investigate the clinical use of a novel whole-body magnetic resonance imaging (MRI) system for comprehensive assessment of tumor spread in clinical routine. MATERIAL AND METHODS: Sixty-five patients with different tumors with known metastatic disease and 6 healthy volunteers were included. High-resolution MRI from head to toe was performed using multiple phased-array surface coil elements, 24 independent receiver channels, and an integrated parallel acquisition technique (iPAT). A total room time of less than 60 minutes was required. Whole-body MRI and conventional spiral computed tomography (CT) were independently evaluated and compared in terms of feasibility, location/number of detected metastases, and therapeutic relevance. RESULTS: Whole-body MRI was successfully performed in 68 of 71 subjects. Compared with CT, more metastases were detected by MRI in 11 of 63 patients (17%), particularly in brain, liver, spleen, lymph nodes, bone marrow, muscle, and subcutaneous fat tissue. According to these findings, therapy had to be modified in 6 of 63 patients (10%). CONCLUSIONS: High-resolution whole-body MRI is feasible in clinical routine within 1 single examination and offers great potential for fast assessment of individual tumor spread and total tumor burden.

Adolescent↗

Functional characterization of prostate cancer by integrated magnetic resonance imaging and oxygenation changes during carbogen breathing.

OBJECTIVE: The objective of this study was to evaluate the changes in oxygenation of prostate cancer induced by carbogen breathing using blood oxygen level-dependent (BOLD) magnetic resonance image (MRI) with an endorectal coil (eMRI). MATERIALS AND METHODS: In 32 patients with biopsy-proven prostate cancer, endorectal MRI was performed at 1.5 Tesla using the BOLD method. Images were acquired during 4 x 4-minute episodes alternating between room air and carbogen (95% O2/5% CO2) breathing. In each episode, 40 images were acquired (T2*-weighted EPI sequence, 12-14 slices, 3-mm thickness). All patients underwent radical prostatectomy; BOLD-MRI findings were correlated with the histopathologic results. RESULTS: BOLD-MRI could be evaluated in 29 patients, and revealed heterogeneous signal changes of normal prostate and cancer tissue similar to the heterogeneity of prostate tissue in anatomic/pathologic preparation. A significant signal intensity increase (P = 0.004) was found in normal central gland and peripheral zone during carbogen breathing. Signal enhancement in carcinoma was significantly lower (P = 0.004) compared with the contralateral normal side. CONCLUSION: Intrinsic blood-tissue contrast-functional MRI during carbogen breathing may help detect and characterize prostate carcinoma from normal tissue, particularly in small 1-sided carcinomas. This may be useful for identifying candidates for radiotherapy and monitoring noninvasive therapeutic approaches.

Aged↗

Preoperative magnetic resonance imaging-guided localization of 131 breast lesions with modified embolization coils.

OBJECTIVES: The objectives of this study were to assess practicability, outcome, and possible advantages of magnetic resonance imaging (MRI)-guided localizations with modified embolization coils for exclusively MRI-detected suspicious breast lesions. MATERIALS AND METHODS: We performed 131 MRI-guided preoperative localizations in 105 patients with exclusively MRI-detected breast lesions. Contrast-enhanced, T1-weighted, 3-dimensional gradient echo sequences were used for imaging. Breast fixation and needle guidance were achieved by a perforated plate. Lesion localization was performed with a modified embolization coil. The distance between coil and lesion was measured. Results of specimen radiography and histopathology were analyzed. RESULTS: Thirty-four of 131 lesions (26%) were malignant. Lesion localization and excision was successful in all patients. The mean distance between the coil and the lesion was 0.5 mm (+/-1.7 mm standard deviation). CONCLUSIONS: Exact MRI-guided preoperative localization of exclusively MRI-detected breast lesions by using a modified embolization coil is feasible with excellent precision. Advantages over wire localization procedures are the possibility of specimen x-ray and the independence from time and place of operation.

Adult↗

Magnetic resonance-guided percutaneous radiofrequency ablation of renal cell carcinomas: a pilot clinical study.

OBJECTIVE: The objective of this study was to assess the feasibility and efficacy of magnetic resonance imaging-(MRI) guided percutaneous radiofrequency (RF) ablation of renal cell carcinomas (RCC). SUBJECTS AND METHODS: Twelve patients with RCC (63 to 82 years old) were treated with RF ablation in an interventional 0.2-Tesla open MR unit. Tumor sizes varied from 1.6 cm to 3.9 cm in maximum diameter (tumor volumes 1.9 cm3 to 28.7 cm3). RF procedures were entirely performed in the MR suite. For positioning of the MR-compatible RF-electrode, near real-time MR fluoroscopy by means of rapid gradient echo sequences (acquisition time approximately 2 seconds) was used. Monitoring of ablation was obtained by intermittent imaging with T1- and T2-weighted spin echo sequences. RESULTS: Accurate placement of the RF electrodes was possible in all cases using near real-time MR fluoroscopy. Eleven of 12 patients were successfully treated within 1 single session; 1 patient had to be retreated for tumor relapse at 13 months follow up. Mean number of electrode repositionings under MR guidance during 1 session was 1.7; ablation time ranged between 12 and 28 minutes. Mean duration of 1 treatment session was 5 hours. Coagulation volumes ranged from 7.3 cm3 up to 30.2 cm3. All patients now appear to be disease-free with a mean follow up of 10.3 months (range, 3-23 months). CONCLUSION: MRI-guided RF ablation of RCC in an interventional MR unit is safe and feasible. Fast MR imaging is a convenient method for rapid positioning of MR-compatible RF electrodes. MR monitoring of ablation procedure with T2-weighted imaging allows for immediate assessment of coagulation extent.

Aged↗

Focal gene induction in the liver of rats by a heat-inducible promoter using focused ultrasound hyperthermia: preliminary results.

OBJECTIVE: We sought to examine high-intensity focused ultrasound (HIFU)-induced hyperthermia in the liver of a rat model to focally induce green-fluorescent protein (GFP). MATERIALS AND METHODS: A total of 25 Copenhagen rats were included in this study. Rats were divided into groups treated with an adenovirus coding for green fluorescent protein (GFP) under the control of a hsp70B promoter and a CMV promoter. Ad-CMV-GFP-treated rats served as positive control. Untreated controls only subjected to MRI +/- HIFU-treatment served to find out optimal power of HIFU in the target area of the liver. Temperature was noninvasively monitored by temperature sensitive magnetic resonance imaging (MRI). RESULTS: Rats treated with Ad-hsp70B-GFP demonstrated localized gene induction within the liver parenchyma, in good correlation with MRI and histology. Applying an acoustic power of 1.92 W a relatively uniform focal temperature up to 42 +/- 5 degrees C within the liver parenchyma could be documented. 3 x 10(9) plaque-forming units proved to account for a very homogeneous liver infection. Number of fluorescent cells in the region of hyperthermia was similar to the control group treated with Ad-CMV-GFP. CONCLUSION: Using the introduced parameters spatially controlled gene induction within a parenchymal organ such as the liver in rats using HIFU under control of MRI is feasible.

Adenoviridae↗

Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences.

PURPOSE: The authors conducted a clinical evaluation of single-slab, 3-dimensional, T2-weighted turbo-spin-echo (TSE) with high sampling efficiency (SPACE) for high isotropic body imaging with large field-of-view (FoV). MATERIALS AND METHODS: Fifty patients were examined in clinical routine with SPACE (regions of interest: pelvis n=30, lower spine n=12, upper spine n=6, extremities n=4) at 1.5 T. For achieving a high sampling efficiency, parallel imaging, high turbofactor, and magnetization restore pulses were used. In contrast to a conventional TSE imaging technique with constant flip angle refocusing, the refocusing pulse train of the SPACE sequence consists of variable flip angle radiofrequency pulses along the echo train. RESULTS: Signal-to-noise ratio and contrast-to-noise ratio of SPACE images were of sufficient diagnostic value. The possibility of image reconstruction in multiple planes was of clinical relevance in all cases and simplified data analysis. CONCLUSION: The achievement of 3-dimensional, T2-weighted TSE magnetic resonance imaging with isotropic and high spatial resolution and interactive 3-dimensional visualization essentially improve the diagnostic potential of magnetic resonance imaging.

Abdominal Neoplasms↗

[Positive contrast in the detection of magnetically labeled cells by MRI--in vitro experiments].

PURPOSE: Magnetically labeled cells (MLC) cause local field inhomogenities within the single voxels as well as on a macroscopic scale. The related Larmor frequency shift near MLC was exploited to obtain bright visualization applying spectral selective saturation (SSS). METHODS: SK-Mel28 cells were labeled with the superparamagnetic iron oxide contrast agent SHU 555A. Low cell concentrations (0, 5, 20, 30, 50, 75, and 150 MLC/microl) and high cell concentrations (10 x 10(3), 30 x 10(3), 60 x 10(3), and 100 x 10(3) MLC/10 microl) were examined at 3 Tesla. Shimming and frequency adjustment to spectrometer reference frequency v0 was performed with the built in routine of the scanner. A 2D spin echo sequence with broadband excitation and refocusing pulses was used (BWex = 1.000 Hz). Prior to each TR, a non-selective saturation sinc pulse centred at v0 was applied. Bandwidth (BWsat) of this pulse was varied from 100 Hz to 800 Hz in logarithmic steps. RESULTS: Without SSS the highest value of Crel (i.e. relative MR contrast between labeled to unlabeled samples) was found for 150 MLC/microl and was given by 10%. Applying SSS led to positive contrast of the complete labeled volumes and to remarkable improvements in Crel. With increasing cell concentrations Crel raised to maximum, that was given by 52% (BWsat=100 Hz) and 28% (BWsat = 200 Hz) found for 75 MLC/microl. For 150 MLC/microl Crel decreased. A contrast clarification could also be detected near cell aggregations despite saturation. CONCLUSION: Using SSS positive contrast can be achieved for voxels containing MLC and voxels close to cell clusters. Under in vitro conditions positive contrast improved the sensitivity to detect MLC as compared to negative contrast imaging techniques. It seems reasonable, that positive contrast approaches can be applied in vivo as the underlying physical mechanism are comparable.

Cell Line, Tumor↗

Thermal damage of the genitofemoral nerve due to radiofrequency ablation of renal cell carcinoma: a potentially avoidable complication.

OBJECTIVE: A technique is presented that may prevent damage to the genitofemoral nerve during percutaneous radiofrequency ablation of renal cell carcinomas. The genitofemoral nerve originates from the upper part of the lumbar plexus and descends laterally along the psoas major muscle, which is anatomically close to the kidney. During radiofrequency ablation, nearby healthy nerve tissue could be damaged by heat conductance. In the described technique, the radiofrequency applicator within the renal tumor is used as a lever to displace the kidney away from the psoas muscle. CONCLUSION: Three clinical cases are presented in this study. In one case, the technique was not applied, leading to coagulation of the genitofemoral nerve. In the other two cases, hazard to the genitofemoral nerve was averted by using the mentioned technique.

Aged↗

Rational diagnosis of squamous cell carcinoma of the head and neck region: comparative evaluation of CT, MRI, and 18FDG PET.

OBJECTIVE: We sought to evaluate the efficiency of (18)FDG PET, CT, and MRI for the preoperative staging of squamous cell carcinoma (SCC) of the head and neck region. CONCLUSION: MRI is recommended as the method of choice in the preoperative evaluation of SCC of the oral cavity and the oropharynx. PET can provide relevant diagnostic information in case of equivocal findings by MRI or CT. Routine use of PET, however, does not appear to be necessary if optimized MRI is available.

Adult↗

ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses.

OBJECTIVE: The aim of this study was to investigate image quality and diagnostic accuracy in detecting coronary artery lesions using a 16-MDCT scanner. MATERIALS AND METHODS: Thirty-seven patients (28 men, nine women) underwent unenhanced helical CT and MDCT angiography of the coronary arteries. After patients received oral beta-blocker medication, CT scans were obtained during a single breath-hold with a 16-MDCT scanner using ECG-gating (0.75-mm collimation, 2.8-mm table feed/rotation, 0.42-sec rotation time). The image quality was assessed in terms of artifacts and segment visibility by two reviewers. Stenosis severity was compared with the results of conventional invasive coronary angiography. RESULTS: The data evaluation of the image quality was based on a total of 488 segments, of which 380 segments were considered to have diagnostic image quality. One hundred eight segments (22.1%) could not be sufficiently evaluated because of severe calcifications (35 segments) and motion artifacts (73 segments). The mean calcium score (Agatston score equivalent [ASE]) was 524.3 +/- 807.6. Twenty-eight (75.7%) of the 37 patients had an ASE of less than 1,000 (mean ASE, 90.8 +/- 152.3 [SD]), and nine (24.3%) patients had an ASE of 1,000 or greater (mean ASE, 1,761.0 +/- 637.6). For detecting lesions 50% or greater (without any exclusion criteria), the overall sensitivity, specificity, positive predictive value, and negative predictive value were 59%, 87%, 61%, and 87%, respectively. When limiting the number of patients to those with a calcium score of less than 1,000 ASE, the threshold-corrected sensitivity for lesions 50% or greater was 93%; specificity, 94%; positive predictive value, 68%; and negative predictive value, 99%. CONCLUSION: In patients with no or moderate coronary calcification, MDCT of coronary arteries using 16-MDCT technology allows the reliable detection of coronary artery stenoses with high diagnostic accuracy. Obtaining an initial unenhanced scan was found to be mandatory to avoid performing useless examinations in patients with severe calcifications.

Adrenergic beta-Antagonists↗

Detection of regional myocardial perfusion deficit using rest and stress perfusion MRI: a feasibility study.

OBJECTIVE: Providing high temporal and spatial resolution, perfusion MRI is an attractive alternative to traditional radionuclide methods like SPECT and PET. Although first-pass perfusion MRI examinations have gained increasing attention during the past years, this technique still exhibits relatively low signal-to-noise ratio and cardiac coverage. Previous studies have suggested that refocused gradient sequence technology (e.g., true fast imaging with steady-state precession [FISP]) should improve perfusion MRI examinations. The aim of this study was to assess myocardial perfusion deficits in patients with proven coronary artery disease using a saturation recovery true FISP perfusion sequence. SUBJECTS AND METHODS: Rest and stress perfusion MRI studies were performed in 22 patients with coronary artery disease at 1.5 T using a multislice saturation recovery true FISP sequence after the bolus injection of 0.025 mmol/kg of body weight of gadopentetate dimeglumine. The myocardium of each slice was divided into 12 radial segments with subdivision into subendocardial and subepicardial subregions. Myocardial perfusion was assessed semiquantitatively and independently for each subregion. The standard of reference for myocardial perfusion was SPECT. Delayed enhancement images were acquired after the injection of 0.15 mmol/kg of body weight of gadopentetate dimeglumine. RESULTS: Sensitivity and specificity of perfusion MRI examinations for the detection of perfusion deficits were 81% and 89%, respectively, for the semiquantitative perfusion parameter upslope and 78% and 86% for the parameter peak signal intensity. More specifically, rest perfusion examinations were able to detect areas of infarction, whereas stress examinations increased the perfusion differences between normal and ischemic myocardial areas. Excellent correlation was observed between rest perfusion and late enhancement findings (r = 0.90). CONCLUSION: In patients with single-vessel coronary artery disease, perfusion deficits can reliably be detected using a saturation recovery true FISP sequence. Semiquantitative perfusion parameters upslope and peak signal intensity yielded similar results.

Adult↗

3D proton MR spectroscopic imaging of prostate cancer using a standard spine coil at 1.5 T in clinical routine: a feasibility study.

The objective of this study was to demonstrate the feasibility of 3D proton MR spectroscopic imaging (MRSI) of the prostate using a standard spine instead of a dedicated endorectal coil at 1.5 T. Twenty-eight patients (25 with biopsy proven prostate cancers and three patients with a benign prostate hyperplasia) were examined. MRI and MRSI were conducted with commercial array surface coils at 1.5 T. Ratios of choline (Cho), creatine (Cr) and citrate (Ci) were calculated for tumour, central and peripheral zone retrospectively, based on axial T2 weighed MR images and histology reports. Prostate cancer was characterized by significantly elevated (Cho+Cr)/Ci ratio compared with non-tumourous prostate tissue. The quality of all proton MR spectra was considered to be good or acceptable in 17/28 patients (61%) and poor in 11/28 (39%) examinations. In 20/25 patients with proven malignancy (80%), MRSI was considered to be helpful for the detection of prostate cancer. In 4/25 patients with proven malignancy (16%) who underwent seed implantation, radiotherapy or hormone deprivation before MR examination spectroscopy was of poor and non-diagnostic quality. MRSI of the prostate is feasible within clinical routine using the spine array surface coil at 1.5 T. It can consequently be applied to patients even with contraindications for endorectal coils. However, spectral quality and signal-to-noise ratio is clearly inferior to 3D MRSI examinations with endorectal coils.

Adult↗