PubMed Health⌕ Search

Biomedical subjects

Claus D Claussen

Publications and source records attributed to Claus D Claussen.

128 records · Page 8Linked to original sources

Image quality and diagnostic accuracy of 16-slice multidetector spiral computed tomography for the detection of coronary artery disease in elderly patients.

OBJECTIVES: To determine the image quality and diagnostic accuracy of cardiac multislice spiral computed tomography (MSCT) in elderly patients (>65 years old) in comparison to younger patients, this retrospective analysis was performed. METHODS: The catheter-controlled MSCT results from patients older than 65 years of age were compared with the results of younger patients in a cohort of 117 patients with regard to sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and image quality. Fifty-three patients were older than 65 years of age (group 1: 31 men, age range: 72.2 +/- 4.1 years, number of risk factors: 2.6 +/- 1.3, Agatston score: 866 +/- 1090) and 64 were younger (group 2: 45 men, age range: 57.4 +/- 6.1 years, number of risk factors: 2.6 +/- 1.0, Agatston score: 765 +/- 1013). All patients were examined by MSCT (Sensation 16 Speed 4 D; Siemens, Forchheim, Germany, with a gantry rotation time of 375 milliseconds) and invasive coronary angiography. The MSCT results were compared blinded with the results of the coronary angiography with regard to the presence or absence of significant stenosis (>50%) in a 13-segment model. Image quality was assessed on a qualitative scale between 1 (very good) and 5 (insufficient image quality) for each segment. RESULTS: Sensitivity, specificity, PPV, and NPP were not different statistically in both groups (group 1: 0.80/0.96/0.89/0.93 and group 2: 0.89/0.98/0.93/0.97). Three patients (all <65 years old) had to be excluded from analysis because of technical problems. Image quality was significantly better in group 2. Gender, body mass index, number of risk factors, and mean heart rate were not significantly different in either group. CONCLUSIONS: Age has an impact on MSCT image quality but did not hamper diagnostic accuracy. Thus, MSCT is a noninvasive method to detect or rule out coronary artery disease independently of age. These retrospective data have to be confirmed in larger prospective trials.

Age Factors↗

Detection of pulmonary embolism using 16-slice multidetector-row computed tomography: evaluation of different image reconstruction parameters.

OBJECTIVE: To compare different image reconstruction parameters for detecting emboli of the pulmonary arteries according to anatomic levels using 16-slice multidetector-row computed tomography in patients suspected of having an acute pulmonary embolism (PE). METHODS: Sixty-two patients (33 male and 29 female) with a clinically suspected acute PE were included in the present study. Multidetector-row computed tomography scans were performed using 16-mmx0.75-mm collimation. Based on the computed tomography data set, different image reconstruction parameters were used for each patient: axial slice thicknesses (STs) of 0.75, 2, 4, and 6 mm; axial maximum intensity projection (MIP) STs of 4 mm; and coronal STs of 2 and 4 mm. In joint reading fashion, 2 experienced radiologists reviewed examination findings regarding the presence and/or absence of a PE. The reference standard for visualization and detection of PEs was defined using the axial images with a 0.75-mm ST. RESULTS: In 23 of 62 patients, a PE was diagnosed. For main and lobar pulmonary arteries, the sensitivities and specificities were as follows: axial 2-mm images, 1.0/1.0; axial 4-mm images, 1.0/1.0; axial 6-mm images, 0.97/0.99; MIP 4-mm images, 0.95/0.99; coronal 2-mm images, 1.0/1.0; and coronal 4-mm images, 1.0/1.0. Regarding segmental and subsegmental pulmonary arteries, sensitivity and specificity varied: axial 2-mm images, 0.97/1.0; axial 4-mm images, 0.81/0.99; axial 6-mm images, 0.65/0.99; axial MIP 4-mm images, 0.63/0.99; coronal 2-mm images, 0.91/0.99; and coronal 4-mm images, 0.74/0.99. CONCLUSIONS: In detecting segmental and subsegmental PEs, only the axial images with an ST of 2 mm proved to have results comparable with the axial 0.75-mm images. Therefore, thin-slice collimation and ST are mandatory for visualization of segmental and subsegmental PEs in patients suspected of having an acute PE.

Aged↗