Robotically assisted repair of a papillary muscle injury due to blunt trauma.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Clifton C Reade.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: Robotic mitral valve repair increases precision however operative times are longer. Prior studies have indicated that robotic knot tying is time consuming and it is without potential room for improvement. We therefore investigated tissue approximation devices that may shorten operative times. DESCRIPTION: A 67-year-old female was approached through a right mini-thoracotomy with the da Vinci Robotic Surgical System (Intuitive Surgical, Sunnyvale, CA). Using 12 nitinol U-clips (Coalescent Surgical, Sunnyvale, CA) an annuloplasty band was placed under robotic guidance. Clip placement and deployment times were recorded and statistical comparisons were assessed to prior suture annuloplasties. EVALUATION: Clip placement time was 1.3 +/- 0.9 (minutes +/- standard deviation), statistical comparison with first, most recent, and all prior suture annuloplasties proving no significance. Clip deployment time was 0.5 +/- 0.2, whereas knot-tying times and respective statistical comparison for first, most recent, and all prior suture annuloplasties were 2.0 +/- 0.7 (p = 0.003), 1.2 +/- 0.4 (p = 0.0004), and 1.6 +/- 0.6 (p < 0.00001). Follow-up echocardiography performed postoperatively, at 3 months, and at 9 months revealed valvular structural integrity with only minimal mitral regurgitation. CONCLUSIONS: U-clips considerably reduce time for annuloplasty over conventional suture and may help reduce operative times as well.
BACKGROUND: Left atrial microwave ablation for atrial fibrillation has become popular for isolating autonomous atrial foci. Previously, mitral valve repairs (MVP) with atrial fibrillation ablation have been performed through sternotomy. We present a technique that combines robotic MVP with left atrial fibrillation ablation. METHODS: Through a 4-cm right minithoracotomy and using cardiopulmonary bypass, the transverse and oblique sinuses are accessed. A Flex-10 microwave catheter is passed around the pulmonary veins, and after weaning from cardiopulmonary bypass, peripulmonary vein microwave ablations are performed. After cardioplegic arrest, the da Vinci system is used to manipulate the catheter to create endocardial lesions around the left atrial appendage. Another endocardial lesion is made connecting the pulmonary venous line with the mitral annulus near P3. The left atrial appendage is closed, and the MVP performed robotically. Data are expressed as mean +/- standard deviation. RESULTS: Sixteen patients underwent this combined procedure, with 80% returning to a normal sinus rhythm at 6 weeks and 73% remaining in normal sinus rhythm at 6 months. Only 1 patient was in atrial fibrillation at 6 months. The ablation procedure added 42 +/- 16.1 minutes to a robotic MVP. The average length of hospital stay was 6.3 +/- 2.2 days, 1.3 days longer than the mean of the prior 50 consecutive robotic MVP patients without a concomitant ablation. CONCLUSIONS: Robotic microwave ablation during robotic MVP is a safe, effective way to resolve atrial fibrillation. These methods offer a promising prelude to the combined totally endoscopic treatment of atrial arrhythmias and mitral insufficiency.
OBJECTIVES: In minimally invasive and robotic mitral valve surgery, a blade retractor is used to elevate the left atrial roof, which often distorts tissue and impairs visualization. We tested the hemodynamic and histologic changes of intra-atrial suction, using a new suction retractor that may improve stabilization and visualization. METHODS: Swine were divided into 3 equal (n = 4) groups: blade retractor, suction retractor, and arrested heart control. Left atrial ultrasonic crystals were used to record ejection fractions. After cardioplegic arrest, the atrium was opened and sampled for preretractor histology. Retractors remained in place for 1 hour, followed by postretractor histologic sampling. Controls were crossclamped for an equivalent time and postarrest histologic data obtained. Animals were weaned from bypass, data were collected for 4 hours, and postsacrifice atrial histologic samples were obtained. RESULTS: The main effect due to treatment was not statistically significant ( P = .52) between the 3 groups, with the 4-hour average ejection fraction for blade retractor, suction retractor, and control being statistically equivalent at 33.3% +/- 8.3, 35.3% +/- 12.1, and 40.8% +/- 9.9 (mean +/- standard deviation), respectively. Histology showed equivalent amounts of myocyte fragmentation, interstitial edema, eosinophilia, and wavy fibers between blade retraction and suction retraction, while the latter showed slightly increased amounts of hemorrhage. CONCLUSIONS: Atrial endocardial suction retraction appears to be safe with no acute changes in the left atrial ejection fraction or significant acute histologic differences, compared to blade retraction. Furthermore, intra-atrial suction may be applicable to procedures other than minimally invasive and robotic mitral valve repair for providing improved stabilization.
Historically, contraindications to minimally invasive or robotic mitral valve surgery have included prior mastectomy, thoracic reconstruction, or chest radiation. However, we believe that by granting flexibility in the choice of skin incision site while performing careful dissection, surgeons can provide these patients the outstanding results afforded by a minithoracotomy. We present a patient who had undergone a prior mastectomy and radiation treatment in whom we performed a minimally invasive mitral valve repair through a right-sided minithoracotomy using the previous mastectomy incision.
Historically, patients with prior aortic valve replacements who subsequently present with an ascending aortic aneurysm require placement of a valve conduit. However, if the patient has a functional mechanical valve with proven long-term durability, an attempt can be made to preserve the intact valve and to graft the aneurysmal aortic root. The case is described of a patient with a previously placed Starr-Edwards aortic valve who subsequently developed a 6-cm ascending aortic aneurysm. By removing the valve ball and using the existing sewing ring, a proximal graft anastomosis was created with ease, eliminating valve excision.
BACKGROUND AND AIM OF THE STUDY: Reoperative cardiac surgery carries a greater morbidity and mortality than primary cardiac surgery. The study aim was to compare perioperative outcomes in patients undergoing mitral valve surgery who had already undergone a previous cardiac operation using either a minimally invasive video-assisted (MIVA) mini-thoracotomy or a redo median sternotomy (MS). METHODS: Between January 1996 and June 2003, 71 consecutive patients with prior cardiac surgery underwent mitral valve surgery. Of these operations, 38 were MIVA procedures, performed through a 5-cm right anterior thoracotomy using voice-activated robotic camera control (AESOP 3000). Outcome was compared with results in 33 consecutive patients who underwent a standard redo MS. RESULTS: The MIVA and redo MS cohorts differed in preoperative ejection fraction (46 +/- 2% versus 55 +/- 2%; p = 0.004) and percentage of urgent operations (33 versus 8.3%; p = 0.01). Operative mortality was similar in both groups (5.7% and 5.9% respectively; p = 0.976), as were cardiopulmonary bypass, operating room, and ICU times. Postoperative intubation time was shorter in the MIVA group than in the redo MS group (29.1 +/- 8.9 versus 38.0 +/- 9.9 h; p = 0.008), and blood transfusion requirements were also reduced (2.9 +/- 0.6 versus 5.5 +/- 0.7 units; p = 0.001) respectively. Length of hospital stay was significantly less in the MIVA group (7.1 +/- 1.3 versus 11.2 +/- 1.1 days; p = 0.001). CONCLUSION: Minimally invasive video-assisted mitral valve operations may be performed safely and efficiently in patients with prior cardiac surgery. Demonstrated advantages include fewer red blood cell and blood product transfusions, as well as decreased intubation time and length of hospital stay.
Our institution has performed over 100 robot-assisted mitral valve repairs. The procedure has shown many advantages to conventional sternotomy-based repair. However, the robotic approach leads to longer cross-clamp and bypass times than conventional sternotomy. As a result of the increased risk of myocardial damage and arrhythmias from lengthy arrest times, nitinol U-clips have been used in the laboratory and currently in patients for the tissue-annuloplasty ring approximation. The technology replaces the time-consuming task of knot tying, as well as provides better visualization during placement of the annuloplasty ring. The animal studies show excellent tissue incorporation. Short-term echocardiographic imaging shows durability without evidence of mitral stenosis or regurgitation. Further studies are ongoing in our patient population, and the data suggest shorter, more efficient and effective robot-assisted mitral valve repairs.
BACKGROUND: Robotic mitral valve repair with the da Vinci robotic surgical system has been performed in more than 70 patients at our institution. This procedure reduces the need for blood transfusions, shortens hospital stay, and hastens return to normal activities. However, the robot-assisted repair also requires longer cardiopulmonary bypass and arrested-heart times than conventional open repairs. Because of increased risk of myocardial damage, arrhythmia, and other significant morbidities associated with longer arrested-heart time, a more efficient tissue approximation and adherence technique was evaluated to reduce operating time. METHODS: Twelve Dorset sheep were divided equally into 2 groups. In the control group Cosgrove-Edwards annuloplasty bands were secured to the posterior annulus with conventional 2-0 Ticron mattress sutures placed with robotic assistance. In the experimental group, the band was secured with double-armed nitinol U-clips placed with robotic assistance. Postoperative echocardiography was used to assess mitral valve function, and the animals were sacrificed at 3 or 6 months for histological evaluation. RESULTS: Total U-clip placement time was significantly decreased at 2.6 +/- 0.2 (mean +/- SEM) minutes versus total suture placement time at 4.9 +/- 0.4 minutes (P =.001). The main difference in time occurred between clip deployment at 0.75 +/- 0.1 minutes and suture tying at 2.78 +/- 0.2 minutes (P =.000003). Pathologic review showed excellent band incorporation at 3 and 6 months. Echocardiographic imaging showed no discernible mitral valve stenosis or regurgitation. CONCLUSIONS: With more cardiac procedures progressing toward minimally invasive approaches, novel technology to improve existing techniques must be evaluated. Nitinol U-clips help to reduce arrested-heart time and may improve outcome by decreasing morbidity. U-clip placement is intuitive, easily learned, and effective in securing the annuloplasty band to the mitral annulus.
Mediastinitis is one of the most serious complications of cardiac surgery. The standard of care in mediastinitis includes thorough sequential debridement, flap coverage, and culture-directed antibiotics. The most frequently utilized muscles for flap reconstruction include the rectus abdominus and the pectoralis major. However, in some instances these flaps may be inadequate, unavailable, or fail, thus requiring an alternative choice or adjuvant. Most coronary graft procedures utilize the left internal mammary artery, frequently eliminating the left rectus muscles, while prior open cholecystectomy patients frequently lose availability of their right rectus muscle. In addition, radiation therapy or prior flap failure may exclude other muscle transfer procedures. The omentum offers excellent coverage due to mobility and superb arterial and lymphatic flow. Unfortunately, in the past, this has required a celiotomy in an already critically ill patient. We present a series of 5 patients where the omentum was mobilized laparoscopically and passed through an anterior diaphragmatic incision. This option spares a celiotomy, seals the wound, and hastens recovery in very ill patients. We also present a complete review of literature on the topic and provide an algorithm for complex sternal wound reconstruction.
Explore the source record for details and available documents.
Vacuum Assisted Closure (V.A.C.) Therapy has previously been shown to facilitate healing of wounds. However, the physiological mechanism(s) of this treatment modality and its systemic effects require further investigations. The goal of this porcine study was to investigate the effect of V.A.C. Therapy on the systemic distribution of the inflammatory cytokines interleukin (IL)-6, IL-8, IL-10, and transforming growth factor-beta1. Twelve pigs were each given one full-thickness excisional wound, using electrocautery. Six of the pigs were treated with V.A.C. Therapy and six with saline-moistened gauze. Serum samples were collected immediately after wound creation, and hourly for 4 hours. Samples were analyzed using commercially available enzyme-linked immunosorbent assay kits. During the initial 4 hours of treatment, V.A.C. Therapy resulted in earlier and greater peaking of IL-10 and maintenance of IL-6 levels compared with saline-moistened gauze controls, which showed decreased IL-6 values over the first hour (both at p<0.05). No other treatment-based differences were detected.