PubMed Health⌕ Search

Biomedical subjects

Clinton Rubin

Publications and source records attributed to Clinton Rubin.

18 recordsLinked to original sources

Low-magnitude mechanical signals that stimulate bone formation in the ovariectomized rat are dependent on the applied frequency but not on the strain magnitude.

There is growing evidence that extremely small mechanical signals, if applied at a sufficiently high frequency, can serve as anabolic signals to bone tissue. To determine if the responsiveness of bone to low-magnitude, high-frequency parameters is modulated by endocrine imbalance, ovariectomized (OVX) Sprague-Dawley rats were subjected to whole body vibrations (WBV, 0.15 g) at 45 Hz (n=6) or 90 Hz (n=6) for 10 min/day, and compared to OVX age-matched controls (n=6). Five additional rats were used, in vivo, to establish the induced bone surface strain magnitudes (and strain rates). Following a 28 d protocol, bone formation rates in the metaphysis of the proximal tibia were 159% greater in 90 Hz rats when compared to age-matched controls, but 45 Hz rats were not significantly different from controls. Bone morphology of 90 Hz rats indicated significantly greater trabecular bone volume (22% and 25%) and thicker trabeculae (11% and 12%) over either controls or 45 Hz rats in the epiphysis of the distal femur, respectively. Despite the enhanced sensitivity of the skeleton towards the 90 Hz signal, the strain magnitudes and strain rates induced by this frequency were significantly lower than during 45 Hz vibration, suggesting that factors other than matrix strain are driving the anabolic response. Ideally, such mechanical signals represent a non-pharmacologic means of controlling bone mass and morphology in spite of systemic pressures for bone resorption.

Animals↗

Low-level mechanical signals and their potential as a non-pharmacological intervention for osteoporosis.

BACKGROUND: exercise is recognised as a critical regulatory signal to the skeletal system, but which specific aspects of exercise are responsible for influencing bone mass and morphology and resisting fractures remains unknown. Recent data indicate that extremely low-level mechanical signals are anabolic to bone, and thus may be used, non-invasively, as a form of 'passive' exercise to positively influence skeletal status. OBJECTIVE: to summarise recent experimental studies on the effect of low-level mechanical signals (hypothesised to serve as a surrogate for the spectral content of muscle contractility) as a potential non-pharmacological intervention for osteoporosis. RESULTS: low magnitude mechanical signals are anabolic to bone if applied at a high frequency (15-90 Hz). Long-term animal studies (1 year) show that these low-magnitude mechanical signals can increase cancellous bone volume fraction, trabecular thickness, trabecular number and enhance bone stiffness and strength. Studies in the mouse have shown that these low-level signals will stimulate bone formation rate and labelled surface in cortical and cancellous bone, but the molecular and genetic regulation of this mechanosensitivity is extremely complex. Preliminary studies in children with disabling conditions and post-menopausal women indicate that such signals can be efficacious in reversing and/or preventing bone loss. CONCLUSIONS: considering that the strains (deformations) that result from these low-level vibrations are far below (<1/1000th) those which may cause damage to the bone, we believe they represent a unique, non-pharmacological prophylaxis for osteoporosis. Given that so many physiologic systems are tuned to specific frequencies, such as sight, hearing and touch, it should not be entirely surprising that the musculoskeletal system would be responsive to frequency as well.

Animals↗

Low-level, high-frequency mechanical signals enhance musculoskeletal development of young women with low BMD.

UNLABELLED: The potential for brief periods of low-magnitude, high-frequency mechanical signals to enhance the musculoskeletal system was evaluated in young women with low BMD. Twelve months of this noninvasive signal, induced as whole body vibration for at least 2 minutes each day, increased bone and muscle mass in the axial skeleton and lower extremities compared with controls. INTRODUCTION: The incidence of osteoporosis, a disease that manifests in the elderly, may be reduced by increasing peak bone mass in the young. Preliminary data indicate that extremely low-level mechanical signals are anabolic to bone tissue, and their ability to enhance bone and muscle mass in young women was investigated in this study. MATERIALS AND METHODS: A 12-month trial was conducted in 48 young women (15-20 years) with low BMD and a history of at least one skeletal fracture. One half of the subjects underwent brief (10 minutes requested), daily, low-level whole body vibration (30 Hz, 0.3g); the remaining women served as controls. Quantitative CT performed at baseline and at the end of study was used to establish changes in muscle and bone mass in the weight-bearing skeleton. RESULTS: Using an intention-to-treat (ITT) analysis, cancellous bone in the lumbar vertebrae and cortical bone in the femoral midshaft of the experimental group increased by 2.1% (p = 0.025) and 3.4% (p < 0.001), respectively, compared with 0.1% (p = 0.74) and 1.1% (p = 0.14), in controls. Increases in cancellous and cortical bone were 2.0% (p = 0.06) and 2.3% (p = 0.04) greater, respectively, in the experimental group compared with controls. Cross-sectional area of paraspinous musculature was 4.9% greater (p = 0.002) in the experimental group versus controls. When a per protocol analysis was considered, gains in both muscle and bone were strongly correlated to a threshold in compliance, where the benefit of the mechanical intervention compared with controls was realized once subjects used the device for at least 2 minute/day (n = 18), as reflected by a 3.9% increase in cancellous bone of the spine (p = 0.007), 2.9% increase in cortical bone of the femur (p = 0.009), and 7.2% increase in musculature of the spine (p = 0.001) compared with controls and low compliers (n = 30). CONCLUSIONS: Short bouts of extremely low-level mechanical signals, several orders of magnitude below that associated with vigorous exercise, increased bone and muscle mass in the weight-bearing skeleton of young adult females with low BMD. Should these musculoskeletal enhancements be preserved through adulthood, this intervention may prove to be a deterrent to osteoporosis in the elderly.

Adolescent↗

Molecular pathways mediating mechanical signaling in bone.

Bone tissue has the capacity to adapt to its functional environment such that its morphology is "optimized" for the mechanical demand. The adaptive nature of the skeleton poses an interesting set of biological questions (e.g., how does bone sense mechanical signals, what cells are the sensing system, what are the mechanical signals that drive the system, what receptors are responsible for transducing the mechanical signal, what are the molecular responses to the mechanical stimuli). Studies of the characteristics of the mechanical environment at the cellular level, the forces that bone cells recognize, and the integrated cellular responses are providing new information at an accelerating speed. This review first considers the mechanical factors that are generated by loading in the skeleton, including strain, stress and pressure. Mechanosensitive cells placed to recognize these forces in the skeleton, osteoblasts, osteoclasts, osteocytes and cells of the vasculature are reviewed. The identity of the mechanoreceptor(s) is approached, with consideration of ion channels, integrins, connexins, the lipid membrane including caveolar and non-caveolar lipid rafts and the possibility that altering cell shape at the membrane or cytoskeleton alters integral signaling protein associations. The distal intracellular signaling systems on-line after the mechanoreceptor is activated are reviewed, including those emanating from G-proteins (e.g., intracellular calcium shifts), MAPKs, and nitric oxide. The ability to harness mechanical signals to improve bone health through devices and exercise is broached. Increased appreciation of the importance of the mechanical environment in regulating and determining the structural efficacy of the skeleton makes this an exciting time for further exploration of this area.

Animals↗

High-frequency, low-magnitude vibrations suppress the number of blood vessels per muscle fiber in mouse soleus muscle.

Extremely low-magnitude (0.3 g), high-frequency (30-90 Hz), whole body vibrations can stimulate bone formation and are hypothesized to provide a surrogate for the oscillations of muscle during contraction. Little is known, however, about the potential of these mechanical signals to stimulate adaptive responses in other tissues. The objective of this study was to determine whether low-level mechanical signals produce structural adaptations in the vasculature of skeletal muscle. Eight-week-old male BALB/cByJ (BALB) mice were divided into two experimental groups: mice subjected to low-level, whole body vibrations (45 Hz, 0.3 g) superimposed on normal cage activities for 15 min/day (n = 6), and age-matched controls (n = 7). After the 6-wk experimental protocol, sections from end and mid regions of the soleus muscles were stained with lectin from Bandeiraea Simplicifolia, an endothelial cell marker, and smooth muscle (SM) alpha-actin, a perivascular cell marker. Six weeks of this low-level vibration caused a 29% decrease in the number of lectin-positive vessels per muscle fiber in the end region of the soleus muscle, indicating a significant reduction in the number of capillaries per muscle fibers. Similarly, these vibrations caused a 36% reduction in SM alpha-actin-positive vessels per muscle fiber, indicating a reduction in the number of arterioles and venules. The decreases in lectin- and SM alpha-actin-positive vessels per muscle fiber ratios were not significant in the mid muscle sections. These results demonstrate the sensitivity of the vasculature in mouse skeletal muscle to whole body, low-level mechanical signals.

Adaptation, Physiological↗

Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular bone.

The ability to evaluate fracture risk at an early time point is essential for improved prognostics as well as enhanced treatment in cases of bone loss such as from osteoporosis. Improving the diagnostic ability is inherent upon both high-resolution non-invasive imaging, and a thorough understanding of how the derived indices of structure and density relate to its true mechanical behavior. Using sheep femoral trabecular bone with a range of strength, the interrelationship of mechanical and microstructural parameters was analyzed using multi-directional mechanical testing and micro-computed tomography. Forty-five cubic trabecular bone samples were harvested from 23 adult female sheep, some of whom had received hind-limb vibratory stimuli over the course of 2 years with consequently enhanced mechanical properties. These samples were pooled into a low, medium, or high strength group for further analysis. The findings show that microCT indices that are structural in nature, e.g., structural model index (SMI) (r2=0.85, p<0.0001) is as good as more density oriented indices like bone volume/total volume (BV/TV) (r2=0.81, p<0.0001) in predicting the ultimate strength of a region of trabecular bone. Additionally, those indices more related to global changes in trabecular structure such as connectivity density (ConnD) or degree of anisotropy (DA) are less able to predict the mechanical properties of bone. Interrelationships of trabecular indices such as trabecular number (TbN), thickness (TbTh), and spacing (TbSp) provide clues as to how the trabecular bone will remodel to ultimately achieve differences in the apparent mechanical properties. For instance, the analysis showed that a loss of bone primarily affects the connectedness and overall number of trabeculae, while increased strength results in an increase of the overall thickness of trabeculae while not improving the connectedness. Certainly, the microCT indices studied are able to predict the bulk mechanical properties of a trabecular ROI well, leaving unaccounted only about 15-20% of its inherent variability. Diagnostically, this implies that future work on the early prediction of fracture risk should continue to explore the role of bone quality as the key factors or as an adjuvant to bone quantity (e.g., apparent density).

Absorptiometry, Photon↗

Low magnitude mechanical loading is osteogenic in children with disabling conditions.

UNLABELLED: The osteogenic potential of short durations of low-level mechanical stimuli was examined in children with disabling conditions. The mean change in tibia vTBMD was +6.3% in the intervention group compared with -11.9% in the control group. This pilot randomized controlled trial provides preliminary evidence that low-level mechanical stimuli represent a noninvasive, non-pharmacological treatment of low BMD in children with disabling conditions. INTRODUCTION: Recent animal studies have demonstrated the anabolic potential of low-magnitude, high-frequency mechanical stimuli to the trabecular bone of weight-bearing regions of the skeleton. The main aim of this prospective, double-blind, randomized placebo-controlled pilot trial (RCT) was to examine whether these signals could effectively increase tibial and spinal volumetric trabecular BMD (vTBMD; mg/ml) in children with disabling conditions. MATERIALS AND METHODS: Twenty pre-or postpubertal disabled, ambulant, children (14 males, 6 females; mean age, 9.1 +/- 4.3 years; range, 4-19 years) were randomized to standing on active (n = 10; 0.3g, 90 Hz) or placebo (n = 10) devices for 10 minutes/day, 5 days/week for 6 months. The primary outcomes of the trial were proximal tibial and spinal (L2) vTBMD (mg/ml), measured using 3-D QCT. Posthoc analyses were performed to determine whether the treatment had an effect on diaphyseal cortical bone and muscle parameters. RESULTS AND CONCLUSIONS: Compliance was 44% (4.4 minutes per day), as determined by mean time on treatment (567.9 minutes) compared with expected time on treatment over the 6 months (1300 minutes). After 6 months, the mean change in proximal tibial vTBMD in children who stood on active devices was 6.27 mg/ml (+6.3%); in children who stood on placebo devices, vTBMD decreased by -9.45 mg/ml (-11.9%). Thus, the net benefit of treatment was +15.72 mg/ml (17.7%; p = 0.0033). In the spine, the net benefit of treatment, compared with placebo, was +6.72 mg/ml, (p = 0.14). Diaphyseal bone and muscle parameters did not show a response to treatment. The results of this pilot RCT have shown for the first time that low-magnitude, high-frequency mechanical stimuli are anabolic to trabecular bone in children, possibly by providing a surrogate for suppressed muscular activity in the disabled. Over the course of a longer treatment period, harnessing bone's sensitivity to these stimuli may provide a non-pharmacological treatment for bone fragility in children.

Bone Density↗

Genetically based influences on the site-specific regulation of trabecular and cortical bone morphology.

UNLABELLED: The degree of site-specificity by which genes influence bone quantity and architecture was investigated in the femur of three strains of mice. Morphological indices were highly dependent on both genetic makeup as well as anatomical location showing that the assessment of bone structure from a single site cannot be extrapolated to other sites even within a single bone. INTRODUCTION: The identification of genes responsible for establishing peak BMD will yield critical information on the regulation of bone quantity and quality. Whereas such knowledge may eventually uncover novel molecular drug targets or enable the identification of individuals at risk of osteoporosis, the site-specificity by which putative genotypes cause low or high bone mass (and effective bone morphology) is essentially unknown. MATERIALS AND METHODS: microCT was used to determine morphological and microarchitectural features of the femora harvested from three genetically distinct strains of 4-month-old female mice, each with distinct skeletal mass (low: C57BL/6J [B6], medium: BALB/cByJ [BALB], high: C3H/HeJ [C3H]). Two trabecular regions (distal epiphysis and metaphysis) were considered in addition to four cortical regions within the metaphysis and diaphysis. RESULTS AND CONCLUSIONS: Comparing morphological properties of the different trabecular and cortical femoral regions between the three strains of mice, it was apparent that high or low values of specific parameters of bone morphology could not be consistently attributed to the same genetic strain. Trabecular metaphyseal bone volume, for instance, was 385% larger in C3H mice than in B6 mice, yet the two strains displayed similar bone volume fractions in the epiphysis. Similarly, BALB mice had 48% more trabecular bone than C3H mice in the epiphysis, but there were no strain-specific differences in cortical bone area at the diaphysis. These data suggest that the genetic control of bone mass and morphology, even within a given bone, is highly site-specific and that a comprehensive search for genes that are indicative of bone quantity and quality may also have to occur on a very site-specific basis.

Animals↗

Genetically linked site-specificity of disuse osteoporosis.

UNLABELLED: The genetic influence on bone loss in response to mechanical unloading was investigated within diaphyseal and distal femoral regions in three genetically distinct strains of mice. One mouse strain failed to lose bone after removal of function, whereas osteopenia was evident in multiple regions of the remaining two strains but in different areas of the bone. INTRODUCTION: It is well recognized that susceptibility to osteoporosis is, in large measure, determined by the genome, but whether this influence is systemic or site-specific is not yet known. Here, the extent to which genetic variations influence regional bone loss caused by disuse was studied in the femora of adult female mice from three inbred strains. MATERIALS AND METHODS: Adult C57BL/6J (B6), C3H/HeJ (C3H), and BALB/cByJ (BALB) mice were subjected to 15-21 days of disuse, achieved by hindlimb suspension, and six distinct anatomical regions of the femur were analyzed by high-resolution microCT. RESULTS AND CONCLUSIONS: In B6 mice, the amount of disuse stimulated bone loss was relatively uniform across all regions, with 20% loss of trabecular bone and 10% loss of cortical bone. The degree of bone loss in BALB mice varied greatly, ranging from 59% in the metaphysis to 3% in the proximal diaphysis. In this strain, the nonuniformity of bone loss was directly related to the nonuniform distribution of baseline bone morphology (r2 = 0.94). In direct contrast with BALB and B6, disuse failed to produce significant losses of bone in any of the analyzed regions of the C3H mice. Instead, these animals displayed a unique compensatory mechanism to disuse, where the large loss of calcified tissue from the endocortical surface (-24%) was compensated for by an expansion of the periosteal envelope (10%). These data indicate a strong, yet complex, genetic dependence of the site-specific regulation of bone remodeling in response to a powerful catabolic signal. Consequently, the skeletal region of interest and the genetic make-up of the individual may have to be considered interdependently when considering the pathogenesis of osteoporosis or the efficacy of an intervention to prevent or recover bone loss.

Animals↗

Genetic variations that regulate bone morphology in the male mouse skeleton do not define its susceptibility to mechanical unloading.

Genetics can substantially influence bone morphology and may define the skeleton's response to mechanical unloading. Recent data indicated that disuse produces different site-specific responses in the skeleton of genetically distinct adult female C3H/HeJ (C3H) and BALB/cByJ (BALB) mice; while disuse BALB mice had significantly less bone than age-matched controls in the distal and diaphyseal femur, the removal of weight bearing had a much smaller influence in C3H. Using adult male mice from these two inbred strains, the hypothesis was tested that interactions between genetic variations and anatomic location define bone morphology and its susceptibility to unloading. Four-month-old male BALB and C3H mice were either subjected to 21 days of hindlimb unloading or served as controls. Multiple cortical and trabecular regions within the distal and diaphyseal femur were analyzed by micro-computed tomography. C3H controls had significantly greater diaphyseal and metaphyseal cortical bone area (45% and 32%) and greater metaphyseal trabecular bone volume fraction (67%) than BALB controls, but epiphyseal trabecular bone volume fraction was similar between the two strains. Despite these substantial, site-specific differences in bone morphology, disuse induced similar changes in bone morphology in these two strains. Compared to controls, disuse BALB and C3H had significantly less metaphyseal (17% and 19%) and epiphyseal (10% and 13%) trabecular bone, while diaphyseal and metaphyseal cortical bone geometry was unaffected. These data indicate that the genetic variations that caused spatially nonuniform differences in trabecular and cortical bone morphology between the two strains had little influence on the susceptibility of a specific site to unloading. Cross-gender comparisons with previous data from female BALB and C3H mice further suggest strong interactions by which gender, genotype, and anatomical location define the response of the skeleton to the removal of weight bearing.

Animals↗

Prevention of postmenopausal bone loss by a low-magnitude, high-frequency mechanical stimuli: a clinical trial assessing compliance, efficacy, and safety.

UNLABELLED: A 1-year prospective, randomized, double-blind, and placebo-controlled trial of 70 postmenopausal women demonstrated that brief periods (<20 minutes) of a low-level (0.2g, 30 Hz) vibration applied during quiet standing can effectively inhibit bone loss in the spine and femur, with efficacy increasing significantly with greater compliance, particularly in those subjects with lower body mass. INTRODUCTION: Indicative of the anabolic potential of mechanical stimuli, animal models have demonstrated that short periods (<30 minutes) of low-magnitude vibration (<0.3g), applied at a relatively high frequency (20-90 Hz), will increase the number and width of trabeculae, as well as enhance stiffness and strength of cancellous bone. Here, a 1-year prospective, randomized, double-blind, and placebo-controlled clinical trial in 70 women, 3-8 years past the menopause, examined the ability of such high-frequency, low-magnitude mechanical signals to inhibit bone loss in the human. MATERIALS AND METHODS: Each day, one-half of the subjects were exposed to short-duration (two 10-minute treatments/day), low-magnitude (2.0 m/s2 peak to peak), 30-Hz vertical accelerations (vibration), whereas the other half stood for the same duration on placebo devices. DXA was used to measure BMD at the spine, hip, and distal radius at baseline, and 3, 6, and 12 months. Fifty-six women completed the 1-year treatment. RESULTS AND CONCLUSIONS: The detection threshold of the study design failed to show any changes in bone density using an intention-to-treat analysis for either the placebo or treatment group. Regression analysis on the a priori study group demonstrated a significant effect of compliance on efficacy of the intervention, particularly at the lumbar spine (p = 0.004). Posthoc testing was used to assist in identifying various subgroups that may have benefited from this treatment modality. Evaluating those in the highest quartile of compliance (86% compliant), placebo subjects lost 2.13% in the femoral neck over 1 year, whereas treatment was associated with a gain of 0.04%, reflecting a 2.17% relative benefit of treatment (p = 0.06). In the spine, the 1.6% decrease observed over 1 year in the placebo group was reduced to a 0.10% loss in the active group, indicating a 1.5% relative benefit of treatment (p = 0.09). Considering the interdependence of weight, the spine of lighter women (<65 kg), who were in the highest quartile of compliance, exhibited a relative benefit of active treatment of 3.35% greater BMD over 1 year (p = 0.009); for the mean compliance group, a 2.73% relative benefit in BMD was found (p = 0.02). These preliminary results indicate the potential for a noninvasive, mechanically mediated intervention for osteoporosis. This non-pharmacologic approach represents a physiologically based means of inhibiting the decline in BMD that follows menopause, perhaps most effectively in the spine of lighter women who are in the greatest need of intervention.

Bone Density↗

Transmissibility of 15-hertz to 35-hertz vibrations to the human hip and lumbar spine: determining the physiologic feasibility of delivering low-level anabolic mechanical stimuli to skeletal regions at greatest risk of fracture because of osteoporosis.

STUDY DESIGN: Experiments were undertaken to determine the degree to which high-frequency (15-35 Hz) ground-based, whole-body vibration are transmitted to the proximal femur and lumbar vertebrae of the standing human. OBJECTIVES: To establish if extremely low-level (<1 g, where 1 g = earth's gravitational field, or 9.8 ms-2) mechanical stimuli can be efficiently delivered to the axial skeleton of a human. SUMMARY OF BACKGROUND DATA: Vibration is most often considered an etiologic factor in low back pain as well as several other musculoskeletal and neurovestibular complications, but recent in vivo experiments in animals indicates that extremely low-level mechanical signals delivered to bone in the frequency range of 15 to 60 Hz can be strongly anabolic. If these mechanical signals can be effectively and noninvasively transmitted in the standing human to reach those sites of the skeleton at greatest risk of osteoporosis, such as the hip and lumbar spine, then vibration could be used as a unique, nonpharmacologic intervention to prevent or reverse bone loss. MATERIALS AND METHODS: Under sterile conditions and local anesthesia, transcutaneous pins were placed in the spinous process of L4 and the greater trochanter of the femur of six volunteers. Each subject stood on an oscillating platform and data were collected from accelerometers fixed to the pins while a vibration platform provided sinusoidal loading at discrete frequencies from 15 to 35 Hz, with accelerations ranging up to 1 g(peak-peak). RESULTS: With the subjects standing erect, transmissibility at the hip exceeded 100% for loading frequencies less than 20 Hz, indicating a resonance. However, at frequencies more than 25 Hz, transmissibility decreased to approximately 80% at the hip and spine. In relaxed stance, transmissibility decreased to 60%. With 20-degree knee flexion, transmissibility was reduced even further to approximately 30%. A phase-lag reached as high as 70 degrees in the hip and spine signals. CONCLUSIONS: These data indicate that extremely low-level, high-frequency mechanical accelerations are readily transmitted into the lower appendicular and axial skeleton of the standing individual. Considering the anabolic potential of exceedingly low-level mechanical signals in this frequency range, this study represents a key step in the development of a biomechanically based treatment for osteoporosis.

Adult↗

Combining high-resolution micro-computed tomography with material composition to define the quality of bone tissue.

Atraumatic fractures of the skeleton in osteoporotic patients are directly related to a deterioration of bone strength. However, the failure of the bone tissue to withstand functional load bearing cannot be explained as a simple decrease in bone mineral density (quantity); strength is also significantly dependent upon bone quality. While a formal definition of bone quality is somewhat elusive, at the very least, it incorporates architectural, physical, and biologic factors that are critical to bone strength. Such factors include bone morphology (ie, trabecular connectivity, cross-sectional geometry, longitudinal curvature); the tissue's material properties (eg, stiffness, strength); its chemical composition and architecture (eg, ratio of calcium to other components of the organic and/or inorganic phase, collagen orientation, porosity, permeability); and the viability of the tissue (eg, responsivity of the bone cell population). Combining high-resolution structural indices of bone, as determined by micro-computed tomography; material properties determined by nanoindentation; and the chemical make-up of bone, as determined by infrared spectroscopy, helps to provide critical information toward a more comprehensive assessment of the interdependence of bone quality, quantity, and fracture risk.

Animals↗

Fluid pressure gradients, arising from oscillations in intramedullary pressure, is correlated with the formation of bone and inhibition of intracortical porosity.

Fluid flow that arises from the functional loading of bone tissue has been proposed to be a critical regulator of skeletal mass and morphology. To test this hypothesis, the bone adaptive response to a physiological fluid stimulus, driven by low magnitude, high frequency oscillations of intramedullary pressure (ImP), were examined, in which fluid pressures were achieved without deforming the bone tissue. The ulnae of adult turkeys were functionally isolated via transverse epiphyseal osteotomies, and the adaptive response to four weeks of disuse (n=5) was compared to disuse plus 10 min per day of a physiological sinusoidal fluid pressure signal (60 mmHg, 20Hz). Disuse alone resulted in significant bone loss (5.7+/-1.9%, p< or =0.05), achieved by thinning the cortex via endosteal resorption and an increase in intracortical porosity. By also subjecting bone to oscillatory fluid flow, a significant increase in bone mass at the mid-diaphysis (18.3+/-7.6%, p<0.05), was achieved by both periosteal and endosteal new bone formation. The spatial distribution of the transcortical fluid pressure gradients (inverted Delta P(r)), a parameter closely related to fluid velocity and fluid shear stress, was quantified in 12 equal sectors across a section at the mid-diaphyses. A strong correlation was found between the inverted Delta P(r) and total new bone formation (r=0.75, p=0.01); and an inverse correlation (r=-0.75, p=0.01) observed between inverted Delta P(r) and the area of increased intracortical porosity, indicating that fluid flow signals were necessary to maintain bone mass and/or inhibit bone loss against the challenge of disuse. By generating this fluid flow in the absence of matrix strain, these data suggest that anabolic fluid movement plays a regulatory role in the modeling and remodeling process. While ImP increases uniformly in the marrow cavity, the distinct parameters of fluid flow vary substantially due to the geometry and ultrastructure of bone, which ultimately defines the spatial non-uniformity of the adaptive process.

Animals↗

Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load.

Extremely low magnitude mechanical stimuli (<10 microstrain) induced at high frequencies are anabolic to trabecular bone. Here, we used finite element (FE) modeling to investigate the mechanical implications of a one year mechanical intervention. Adult female sheep stood with their hindlimbs either on a vibrating plate (30 Hz, 0.3 g) for 20 min/d, 5 d/wk or on an inactive plate. Microcomputed tomography data of 1 cm bone cubes extracted from the medial femoral condyles were transformed into FE meshes. Simulated compressive loads applied to the trabecular meshes in the three orthogonal directions indicated that the low level mechanical intervention significantly increased the apparent trabecular tissue stiffness of the femoral condyle in the longitudinal (+17%, p<0.02), anterior-posterior (+29%, p<0.01), and medial-lateral (+37%, p<0.01) direction, thus reducing apparent strain magnitudes for a given applied load. For a given apparent input strain (or stress), the resultant stresses and strains within trabeculae were more uniformly distributed in the off-axis loading directions in cubes of mechanically loaded sheep. These data suggest that trabecular bone responds to low level mechanical loads with intricate adaptations beyond a simple reduction in apparent strain magnitude, producing a structure that is stiffer and less prone to fracture for a given load.

Adaptation, Physiological↗

Genetic predisposition to low bone mass is paralleled by an enhanced sensitivity to signals anabolic to the skeleton.

The structure of the adult skeleton is determined, in large part, by its genome. Whether genetic variations may influence the effectiveness of interventions to combat skeletal diseases remains unknown. The differential response of trabecular bone to an anabolic (low-level mechanical vibration) and a catabolic (disuse) mechanical stimulus were evaluated in three strains of adult mice. In low bone-mineral-density C57BL/6J mice, the low-level mechanical signal caused significantly larger bone formation rates (BFR) in the proximal tibia, but the removal of functional weight bearing did not significantly alter BFR. In mid-density BALB/cByJ mice, mechanical stimulation also increased BFR, whereas disuse significantly decreased BFR. In contrast, neither anabolic nor catabolic mechanical signals influenced any index of bone formation in high-density C3H/HeJ mice. Together, data from this study indicate that the sensitivity of trabecular tissue to both anabolic and catabolic stimuli is influenced by the genome. Extrapolated to humans, these results may explain in part why prophylaxes for low bone mass are not universally effective, yet also indicate that there may be a genotypic indication of people who are at reduced risk of suffering from bone loss.

Adaptation, Physiological↗

The pathway of bone fluid flow as defined by in vivo intramedullary pressure and streaming potential measurements.

The pathway for intracortical fluid flow response to a step-load was identified in vivo using intramedullary pressure (ImP) and streaming potential (SP) measurements, and allowed the development of a load-induced flow mechanism which considers mechanotransduction and mechanoelectrotransduction phenomena. An avian model was used for monitoring, simultaneously, ImP and SP under axial loading which generated peak strains of approximately 600 microstrain (microepsilon). ImP response to step-load decayed more quickly than SP relaxation, in which multiple time constants were observed during the relaxations. While the initial relaxation of SP showed a decay on the order of 200 ms, ImP decayed on the order of approximately 100 ms. After the initial decay (approximately 200 ms after loading), ImP quickly relaxed to base line, while SP continued to dominate relaxation. It appears that the decay of ImP is indicative of resistive fluid flow occurring primarily in the vasculature and other intraosseous channels such as lacunar-canalicular pores, and that SP represents the fluid flow in the smaller porosities, i.e., lacunar-canalicular system or even microspores. These results suggest that SP and ImP decays are determined by a hierarchical interdependent system of multiple porosities, and that the temporal dynamics of load-bearing define the manner in which the fluid patterns and pressures are distributed.

Animals↗

Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention.

The skeleton's sensitivity to mechanical stimuli represents a critical determinant of bone mass and morphology. We have proposed that the extremely low level (< 10 microstrain), high frequency (20-50 Hz) mechanical strains, continually present during even subtle activities such as standing are as important to defining the skeleton as the larger strains typically associated with vigorous activity (>2000 microstrain). If these low-level strains are indeed anabolic, then this sensitivity could serve as the basis for a biomechanically based intervention for osteoporosis. To evaluate this hypothesis, the hindlimbs of adult female sheep were stimulated for 20 minutes/day using a noninvasive 0.3g vertical oscillation sufficient to induce approximately 5 microstrain on the cortex of the tibia. After 1 year of stimulation, the physical properties of 10-mm cubes of trabecular bone from the distal femoral condyle of experimental animals (n = 8) were compared with controls (n = 9), as evaluated using microcomputed tomography (microCT) scanning and materials testing. Bone mineral content (BMC) was 10.6% greater (p < 0.05), and the trabecular number (Tb.N) was 8.3% higher in the experimental animals (p < 0.01), and trabecular spacing decreased by 11.3% (p < 0.01), indicating that bone quantity was increased both by the creation of new trabeculae and the thickening of existing trabeculae. The trabecular bone pattern factor (TBPf) decreased 24.2% (p < 0.03), indicating trabecular morphology adapting from rod shape to plate shape. Significant increases in stiffness and strength were observed in the longitudinal direction (12.1% and 26.7%, respectively; both, p < 0.05), indicating that the adaptation occurred primarily in the plane of weightbearing. These results show that extremely low level mechanical stimuli improve both the quantity and the quality of trabecular bone. That these deformations are several orders of magnitude below those peak strains which arise during vigorous activity indicates that this biomechanically based signal may serve as an effective intervention for osteoporosis.

Animals↗