PubMed Health⌕ Search

Biomedical subjects

Coen Rasch

Publications and source records attributed to Coen Rasch.

9 recordsLinked to original sources

Target definition in prostate, head, and neck.

Target definition is a major source of errors in both prostate and head and neck external-beam radiation treatment. Delineation errors remain constant during the course of radiation and therefore have a large impact on the dose to the tumor. Major sources of delineation variation are visibility of the target including its extensions, disagreement on the target extension, and interpretation or lack of delineation protocols. The visibility of the target can be greatly improved with the use of multimodality imaging. Both in the head and neck and the prostate, computed tomography (CT)-magnetic resonance imaging coregistration decreases the target volume and its variability. CT-positron emission tomography delineation is promising for delineation in head and neck cancer. Despite the better visibility, a different interpretation of the target extension remains a major source of error. The use of coregistration of CT with a second modality, together with improved guidelines for delineation and an online anatomical atlas, increases agreement between observers in prostate, lung, and nasopharynx tumors. Delineation errors should not be treated differently from other geometrical errors. Similar margin recipes for the correction of setup errors and organ motion should be adapted to incorporate the effect of delineation errors. A calculation of a 3-dimensional clinical target volume-planning target volume margin incorporating delineation errors for the head and neck is around 6.1 to 9.7 mm. Given the good local control of IMRT with smaller margins and smaller pathological specimens, it is likely that the delineated CTV frequently overestimates the actual volume.

Head and Neck Neoplasms↗

Dysphagia and aspiration after chemoradiotherapy for head-and-neck cancer: which anatomic structures are affected and can they be spared by IMRT?

PURPOSE: To identify the anatomic structures whose damage or malfunction cause late dysphagia and aspiration after intensive chemotherapy and radiotherapy (RT) for head-and-neck cancer, and to explore whether they can be spared by intensity-modulated RT (IMRT) without compromising target RT. METHODS AND MATERIALS: A total of 26 patients receiving RT concurrent with gemcitabine, a regimen associated with a high rate of late dysphagia and aspiration, underwent prospective evaluation of swallowing with videofluoroscopy (VF), direct endoscopy, and CT. To assess whether the VF abnormalities were regimen specific, they were compared with the VF findings of 6 patients presenting with dysphagia after RT concurrent with high-dose intra-arterial cisplatin. The anatomic structures whose malfunction was likely to cause each of the VF abnormalities common to both regimens were determined by literature review. Pre- and posttherapy CT scans were reviewed for evidence of posttherapy damage to each of these structures, and those demonstrating posttherapy changes were deemed dysphagia/aspiration-related structures (DARS). Standard three-dimensional (3D) RT, standard IMRT (stIMRT), and dysphagia-optimized IMRT (doIMRT) plans in which sparing of the DARS was included in the optimization cost function, were produced for each of 20 consecutive patients with advanced head-and-neck cancer. RESULTS: The posttherapy VF abnormalities common to both regimens included weakness of the posterior motion of the base of tongue, prolonged pharyngeal transit time, lack of coordination between the swallowing phases, reduced elevation of the larynx, and reduced laryngeal closure and epiglottic inversion, contributing to a high rate of aspiration. The anatomic structures whose malfunction was the likely cause of each of these abnormalities, and that also demonstrated anatomic changes after RT concurrent with gemcitabine doses associated with dysphagia and aspiration, were the pharyngeal constrictor muscles (median thickness near midline 2.5 mm before therapy vs. 7 mm after therapy; p = 0.001), the supraglottic larynx (median thickness, 2 mm before therapy vs. 4 mm after therapy; p < 0.001), and, similarly, the glottic larynx. The constrictors and the glottic and supraglottic larynx were, therefore, deemed the DARS. The lowest maximal dose delivered to a stricture volume was 50 Gy. Reducing the volumes of the DARS receiving > or =50 Gy (V(50)) was, therefore, a planning and evaluation goal. Compared with the 3D plans, stIMRT reduced the V(50) of the pharyngeal constrictors by 10% on average (range, 0-36%, p < 0.001), and doIMRT reduced these volumes further, by an additional 10% on average (range, 0-38%; p <0.001). The V(50) of the larynx (glottic + supraglottic) was reduced marginally by stIMRT compared with 3D (by 7% on average, range, 0-56%; p = 0.054), and doIMRT reduced these volumes by an additional 11%, on average (range, 0-41%; p = 0.002). doIMRT reduced laryngeal V(50) compared with 3D, by 18% on average (range 0-61%; p = 0.001). Certain target delineation rules facilitated sparing of the DARS by IMRT. The maximal DARS doses were not reduced by IMRT because of their partial overlap with the targets. stIMRT and doIMRT did not differ in target doses, parotid gland mean dose, spinal cord, or nonspecified tissue maximal dose. CONCLUSIONS: The structures whose damage may cause dysphagia and aspiration after intensive chemotherapy and RT are the pharyngeal constrictors and the glottic and supraglottic larynx. Compared with 3D-RT, moderate sparing of these structures was achieved by stIMRT, and an additional benefit, whose extent varied among the patients, was gained by doIMRT, without compromising target doses. Clinical validation is required to determine whether the dosimetric gains are translated into clinical ones.

Antimetabolites, Antineoplastic↗

Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer.

PURPOSE: To quantify in three dimensions the geometric uncertainties of bladder irradiation (i.e., uncertainties in target delineation, organ motion, and patient setup). METHODS AND MATERIALS: Pelvic CT images were obtained for 10 male bladder cancer patients. Apart from the initial planning CT scan, three follow-up scans were made for each of the patients. The bladder volumes in the planning CT scan were outlined by seven radiation oncologists. One observer also delineated the bladder volumes in the follow-up scans. Two-dimensional scalar maps of the interobserver variation and organ motion of the bladder surfaces were constructed. The setup errors were derived from the portal imaging results of the pooled group of bladder and prostate patients. RESULTS: All bladder volumes were consistently outlined by all observers. Generally small variations occurred (1.5-3 mm, 1 SD), although in 50% of the patients, larger discrepancies were observed in discriminating the bladder from the base of the prostate. Analysis of the portal imaging data showed setup errors of up to 3 mm (1 SD). Organ motion is the predominant geometric uncertainty in the radiotherapy process (5 mm, 1 SD, at the cranial side of the bladder), although 9 of 10 patients were able to preserve a fairly reproducible bladder volume during the complete treatment course. CONCLUSION: Anisotropic margins between the clinical target volume and planning target volume are needed in conformal radiotherapy of the bladder. Especially at the cranial side of the bladder, larger margins are needed because of the impact of bladder shape variation.

Aged↗

A comparison of forward and inverse treatment planning for intensity-modulated radiotherapy of head and neck cancer.

BACKGROUND AND PURPOSE: To compare intensity-modulated treatment plans of patients with head and neck cancer generated by forward and inverse planning. MATERIALS AND METHODS: Ten intensity-modulated treatment plans, planned and treated with a step&shoot technique using a forward planning approach, were retrospectively re-planned with an inverse planning algorithm. For this purpose, two strategies were applied. First, inverse planning was performed with the same beam directions as forward planning. In addition, nine equidistant, coplanar incidences were used. The main objective of the optimisation process was the sparing of the parotid glands beside an adequate treatment of the planning target volume (PTV). Inverse planning was performed both with pencil beam and Monte Carlo dose computation to investigate the influence of dose computation on the result of the optimisation. RESULTS: In most cases, both inverse planning strategies managed to improve the treatment plans distinctly due to a better target coverage, a better sparing of the parotid glands or both. A reduction of the mean dose by 3-11Gy for at least one of the parotid glands could be achieved for most of the patients. For three patients, inverse planning allowed to spare a parotid gland that had to be sacrificed by forward planning. Inverse planning increased the number of segments compared to forward planning by a factor of about 3; from 9-15 to 27-46. No significant differences for PTV and parotid glands between both inverse planning approaches were found. Also, the use of Monte Carlo instead of pencil beam dose computation did not influence the results significantly. CONCLUSION: The results demonstrate the potential of inverse planning to improve intensity-modulated treatment plans for head and neck cases compared to forward planning while retaining clinical utility in terms of treatment time and quality assurance.

Head and Neck Neoplasms↗

The prevention and treatment of radiotherapy - induced xerostomia.

Efforts to reduce the severity of postradiotherapy xerostomia include the use of salivary substitutes to gain symptomatic relief, salivary gland stimulants, agents delivered to protect the glands during radiotherapy (RT), and physical means to partially spare the major salivary glands from RT while adequately irradiating tumor targets. These means include advanced RT treatment planning and salivary tissue transfer to nonirradiated areas. The relative potential gain from each of these strategies is discussed in this article. The combination of partial salivary gland sparing and radiation protectors/stimulants may provide additive or synergistic gains in reducing the severity of xerostomia.

Head and Neck Neoplasms↗

How should we measure and report radiotherapy-induced xerostomia?

Xerostomia is commonly measured and graded using objective measures of major salivary gland output and observer-rated toxicity grading. The separation between the different grades is somewhat ambiguous in the current toxicity grading systems. We propose a new grading system based primarily on the functional deficits associated with xerostomia. Salivary flow rates have been added as a criterion to the grading system, notwithstanding the weak correlation reported in most studies between the symptoms and objective functional measures. In addition to the observer-rated toxicity grading, recording of patient-reported quality of life, using validated instruments, is encouraged.

Head and Neck Neoplasms↗

Margins for translational and rotational uncertainties: a probability-based approach.

PURPOSE: To define margins for systematic rotations and translations, based on known statistical distributions of these deviations. METHODS AND MATERIALS: The confidence interval-based expansion method for translations, known as the "rolling ball algorithm," was extended to include rotations. This new method, which we call the Rotational and Translational Confidence Limit (RTCL) method, is exact for a point with arbitrary rotations and translations or for a finite shape with rotations only. The method was compared with two existing expansion methods: a rolling ball algorithm without rotations, and a convolution (blurring) method which included rotations. On the basis of these methods, planning target volumes (PTVs, expanded clinical target volumes [CTVs]) were constructed for a number of shapes (a sphere, a sphere with an extension, and three prostate cases), and evaluated in several ways by means of a Monte Carlo method. The accuracy of each method was measured by determining the probability of finding the CTV completely inside the PTV (P(CTVinPTV)), using parameters that yield a 90% probability for a sphere-shaped CTV without rotations. Furthermore, with the expansion parameters adjusted to give an equal P(CTVinPTV) for all methods, PTV volumes were compared. RESULTS: With the expansion algorithm parameters chosen to yield P(CTVinPTV) = 90% for a sphere, an average P(CTVinPTV) of 84%, 57%, and 46% was obtained for the other shapes, using the RTCL method, coverage probability, and rolling ball, respectively. With the parameters adjusted to yield an equal P(CTVinPTV) for all methods, the PTV volume was on average 8% larger for the coverage probability method and 15% larger for the rolling ball algorithm compared to the RTCL method. CONCLUSION: The RTCL method provides an accurate way to include the effects of systematic rotations in the margin. Compared to other algorithms, the method is less sensitive to the shape of the CTV, and, given a fixed probability of finding the CTV inside the PTV, a smaller PTV volume can be obtained.

Algorithms↗

Irradiation of paranasal sinus tumors, a delineation and dose comparison study.

PURPOSE: To determine the influence of observer variation and treatment planner variation on the dose delivered to the target and normal structures when irradiating paranasal sinus carcinomas. PATIENTS AND METHODS: Nine patients with paranasal sinus tumors underwent debulking surgery and subsequent radiation therapy. Two observers from two different institutions delineated the clinical target volumes (CTVs) for the elective and the boost volumes. These volumes were expanded in three dimensions with a 5-mm margin. At both institutions, a three-dimensional conformal treatment plan of 46 Gy to the elective volumes, plus 20 Gy to the boost target volumes, was designed. The delineated volumes and treatment plans were compared. RESULTS: The mean volume ratio between institutions of the elective CTVs was 0.9 (standard error = 0.05). The differences were located mainly at the bottom of the nasal cavity and at the frontal border of the target areas. The differences in boost CTVs were large; the mean volume ratio was 2.6 (standard error = 0.58). After expansion of the CTV, the mean distance between the planning target volume (PTV) and the chiasm differed by 0.5 cm between the two institutions. Cases with smaller distances between the PTV and the chiasm had more underdosage to the PTV. This effect was less pronounced for institution A (1 vol.%/cm) than for institution B (10 vol.%/cm) treatment plans, which were less conformal. When the treatment plan was designed for the PTV of institution B, 23 volume % of the PTV of institution A received <95% of the prescribed dose. If the treatment plan was designed for the (on average larger) PTV of institution A, the underdosed volume of PTV at institution B was 17%. The relative underdosage to the "other" PTV was larger when the original treatment plan was more conformal. CONCLUSION: In the irradiation of paranasal sinus cancer, both the treatment planner and the observer have a significant influence on the dose to the target and organs at risk. Both effects are similar in magnitude. The observer effect increases with more conformal treatment plans. Minimizing the observer variation is important for adequate irradiation of paranasal sinus cancer.

Carcinoma, Adenoid Cystic↗

Report of a study on IMRT planning strategies for ethmoid sinus cancer.

AIM: This communication reviews the planning strategies and dose statistics of nine IMRT plans generated for a complex head and neck case. PATIENT AND METHOD: An ethmoid sinus cancer case was sent as an IMRT planning task to all participants of the ESTRO course on "IMRT and Other Conformal Techniques in Practice", held in Amsterdam in June 2001. RESULTS: Nine IMRT plans were generated for the case, the majority of the plans generated with commercial planning systems. The number of beam incidences ranged between four and eleven, while five of the nine beam setups were coplanar. The planning target volume dose homogeneity was inversely correlated with the degree of sparing of the surrounding organs at risk. CONCLUSION: IMRT strategies for complex head and neck cases, such as ethmoid sinus cancer, can be strikingly different in various aspects, such as beam setup, total number of segments, PTV dose coverage and dose statistics for organs at risks.

Adenocarcinoma↗