PubMed Health⌕ Search

Biomedical subjects

Colleen F Sintek

Publications and source records attributed to Colleen F Sintek.

4 recordsLinked to original sources

Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis.

BACKGROUND: Stentless aortic bioprostheses offer excellent hemodynamics and potentially improved durability compared with other bioprostheses. The present report describes the clinical and hemodynamic outcomes for the Freestyle aortic root bioprosthesis in a large, multicenter cohort prospectively followed up for 10 years. METHODS: A total of 725 patients at 8 centers in North America (668 [92%] aged more than 60 years) were followed up prospectively after aortic valve replacement with the Freestyle stentless bioprosthesis. Implant technique was subcoronary in 509, total root in 178, and root inclusion in 38. Follow-up was 4,488 patient-years (mean 6.2 years/patient). RESULTS: For subcoronary, full root, and root inclusion groups, 10-year actuarial freedom from structural valve deterioration was 97.0% +/- 2.2%, 96.0% +/- 4.5%, and 90.9% +/- 11.2%, respectively; and actuarial freedom from reoperation was 91.7% +/- 3.5%, 92.3% +/- 6.0%, and 92.0% +/- 10.7%, respectively. Mean pressure gradient at 10 years was 8.9 +/- 7.9 mm Hg for subcoronary, 7.0 +/- 4.1 mm Hg for full root, and 10.0 +/- 11.1 mm Hg for root inclusion groups; effective orifice area was 1.6 +/- 0.5 cm2, 1.6 +/- 0.6 cm2, and 1.7 +/- 0.5 cm2, respectively. Fredom from moderate or more aortic regurgitation at 10 years was good for all three implant groups, but slightly higher for full root (97.7% +/- 1.6%) compared with subcoronary (87.2% +/- 2.8%) patients (p < 0.005). CONCLUSIONS: The Freestyle stentless aortic root bioprosthesis is a versatile option for aortic valve replacement. Measures of clinical outcomes and prosthesis durability remain excellent through 10 years.

Adult↗

Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: six-month patency rates.

OBJECTIVE: We sought to compare the 6-month angiographic patency rates of greater saphenous veins removed during coronary artery bypass grafting with the endoscopic vein harvest or open vein harvest techniques. METHODS: Two hundred patients undergoing nonemergency on-pump coronary artery bypass grafting were prospectively randomized to either endoscopic vein harvest or open vein harvest. Follow-up angiography of all vein grafts was scheduled at 6 months. Graft patency and disease grades were assigned independently by 2 interventional cardiologists. Leg wound healing was evaluated at discharge, 1 month, and 6 months for evidence of complications. RESULTS: There were 3 conversions from endoscopic vein harvest to open vein harvest because of vein factors. Leg wound complications were significantly lower in the endoscopic vein harvest group (7.4% vs 19.4%, P = .014). On multivariable analysis, endoscopic vein harvest emerged as the only factor affecting wound complications (odds ratio, 0.33). Three deaths (2 perioperative and 1 late) occurred in the endoscopic vein harvest group that were unrelated to vein graft closure. Twenty-four and 29 patients in the endoscopic vein harvest and open vein harvest cohorts, respectively, refused the follow-up 6-month angiography. Therefore a total of 144 angiograms (73 endoscopic vein harvests and 71 open vein harvests) and 336 vein grafts (166 endoscopic vein harvests and 170 open vein harvests) were available for analysis. The overall occlusion rates at 6 months were 21.7% for endoscopic vein harvest and 17.6% for open vein harvest. Additionally, there was evidence of significant disease (>50% stenosis) in 10.2% and 12.4% of endoscopic vein harvest and open vein harvest grafts, respectively. By means of ordinal hierarchic logistic regression, endoscopic vein harvest was not found to be a risk factor for vein graft occlusion or disease (odds ratio, 1.15). Significant predictors were congestive heart failure (odds ratio, 2.87), graft to the diagonal artery territory (odds ratio, 1.76), larger vein conduit size (odds ratio, 1.32), and graft flow (odds ratio, 0.90). CONCLUSION: Endoscopic vein harvest reduces leg wound complications compared with open vein harvest without compromising the 6-month patency rate. The overall patency rate depends on target and vein-related variables and patient characteristics rather than the method of vein harvesting.

Aged↗

Eight-year results after aortic valve replacement with the Freestyle stentless bioprosthesis.

OBJECTIVES: We sought to describe the hemodynamic and clinical outcomes for the Freestyle aortic root bioprosthesis (Medtronic, Inc, Minneapolis, Minn) in a large multicenter cohort prospectively followed for 8 years. METHODS: A total of 700 patients (651 [93%] >60 years of age) at 8 centers in North America were followed prospectively after aortic valve replacement with the Freestyle stentless bioprosthesis; the implant technique was subcoronary in 500, total root in 162, and root inclusion in 38. Follow-up was 3395 patient-years (4.9 +/- 2.3 years per patient). Clinical and echocardiographic follow-up was prospectively obtained at yearly intervals. RESULTS: For the subcoronary, total root, and root inclusion groups, actuarial freedom from valve-related death was 96.8% (SE 3.0%), 92.3% (SE 7.7%), and 90.9% (SE 11.2%), respectively, and freedom from structural deterioration was 98.6% (SE 2.0%), 100.0% (SE 0.0%), and 100.0% (SE 0.0%), respectively. Hemodynamics remained excellent at 6 years. Freedom from moderate or more aortic regurgitation was 86.0% (SE 5.1%), 98.7% (SE 3.9%), and 97.3% (SE 6.6%), respectively. Gradients were slightly lower (P =.0009), and the effective orifice area (P =.02) and freedom from aortic regurgitation were slightly higher (P =.03) with total root than subcoronary implantation. CONCLUSIONS: The Freestyle stentless aortic root bioprosthesis is a versatile option for aortic valve replacement. Measures of clinical outcomes and prosthesis durability remain excellent in multicenter follow-up through 8 years in a population predominantly older than 60 years at the time of the operation.

Adult↗

Randomized trial comparing partial versus complete chordal-sparing mitral valve replacement: effects on left ventricular volume and function.

OBJECTIVE: The merits of retaining the subvalvular apparatus during mitral valve replacement for chronic mitral regurgitation have been demonstrated in numerous retrospective clinical investigations but not in a randomized study. In this report we analyzed the early and late effects of complete versus partial chordal preservation on left ventricular mechanics. METHODS: Forty-seven patients undergoing isolated surgical correction of mitral insufficiency were prospectively randomized to either total or partial chordal-sparing mitral valve replacement. Complete data from 36 patients were available for analysis. Of these individuals, 15 had preservation of the posterior leaflet only (P-MVR group), and 21 had complete preservation of all chordal structures (C-MVR group). Echocardiography was performed preoperatively, at the time of discharge, and after 1 year to determine dimensions, wall stress, left ventricular mass, and ejection function. RESULTS: End-diastolic volume decreased in both groups initially but continued to decline only in the C-MVR cohort. Similarly, although end-systolic volume decreased over time with total chordal preservation, no notable changes were observed in the P-MVR group. In the C-MVR group, end-systolic stress decreased initially but rose slightly by 1 year. In contrast, end-systolic stress remained unchanged at discharge in the P-MVR group and increased at 1 year. In terms of systolic performance, ejection fraction declined after surgical intervention with partial chordal-sparing techniques and did not improve by 1 year. Ejection fraction returned to the preoperative level after an initial decrease in the C-MVR group. Finally, left ventricular mass was reduced in the C-MVR cohort versus no change in the P-MVR group. CONCLUSION: Complete retention of the mitral subvalvular apparatus during mitral valve replacement confers a significant early advantage by reducing left ventricular chamber size and systolic afterload compared with partial chordal preservation. Furthermore, left ventricular ejection performance continues to improve over time, probably because of more favorable left ventricular remodeling.

Adult↗