PubMed Health⌕ Search

Biomedical subjects

Conrad Bessant

Publications and source records attributed to Conrad Bessant.

14 recordsLinked to original sources

Understanding the sources of performance in deep drug response models reveals insights and improvements.

MOTIVATION: Anti-cancer drug response prediction (DRP) using cancer cell lines (CLs) is crucial in stratified medicine and drug discovery. Recently, new deep learning models for DRP have improved performance over their predecessors. However, different models use different input data types and architectures making it hard to find the source of these improvements. Here we consider published DRP models that report state-of-the-art performance predicting continuous response values. These models take chemical structures of drugs and omics profiles of CLs as input. RESULTS: By experimenting with these models and comparing with our simple baselines, we show that no performance comes from drug features, instead, performance is due to the transcriptomics CL profiles. Furthermore, we show that, depending on the testing type, much of the current reported performance is a property of the training target values. We address these limitations by creating BinaryET and BinaryCB that predict binary drug response values, guided by the hypothesis that this reduces the noise in the drug efficacy data. Thus, better aligning them with biochemistry that can be learnt from the input data. BinaryCB leverages a chemical foundation model, while BinaryET is trained from scratch using a transformer-type architecture. We show that these models learn useful chemical drug features, which is the first time this has been demonstrated for multiple testing types to our knowledge. We further show binarizing the drug response values causes the models to learn useful chemical drug features. We also show that BinaryET improves performance over BinaryCB, and the published models that report state-of-the-art performance. AVAILABILITY AND IMPLEMENTATION: Code is available from https://github.com/Nik-BB/Understanding_DRP_models.

Humans↗

Mapping the Arabidopsis organelle proteome.

A challenging task in the study of the secretory pathway is the identification and localization of new proteins to increase our understanding of the functions of different organelles. Previous proteomic studies of the endomembrane system have been hindered by contaminating proteins, making it impossible to assign proteins to organelles. Here we have used the localization of organelle proteins by the isotope tagging technique in conjunction with isotope tags for relative and absolute quantitation and 2D liquid chromatography for the simultaneous assignment of proteins to multiple subcellular compartments. With this approach, the density gradient distributions of 689 proteins from Arabidopsis thaliana were determined, enabling confident and simultaneous localization of 527 proteins to the endoplasmic reticulum, Golgi apparatus, vacuolar membrane, plasma membrane, or mitochondria and plastids. This parallel analysis of endomembrane components has enabled protein steady-state distributions to be determined. Consequently, genuine organelle residents have been distinguished from contaminating proteins and proteins in transit through the secretory pathway.

Arabidopsis↗

Evaluation of a genomics platform for cross-species transcriptome analysis of recombinant CHO cells.

Microarray technology for mammalian cells has been utilized mainly for humans, mouse, and rat gene expression analysis. In this approach the feasibility of cross-species hybridization experiments using Chinese hamster ovary (CHO) cells was evaluated. Sequence alignments of available data for CHO were performed against mouse and rat transcripts to determine the homology between the investigated species. We implemented a probability model based on this homology in order to estimate the chance for successful hybridization using Agilent's 60-mer oligonucleotide platform. Heat-shock expression data from CHO, mouse 3T3, and rat A10 cells were generated to determine intraspecies variability, reproducibility, and specificity in order to assess the accuracy of this method. Detected signature genes, in particular from studies with the mouse arrays, showed a reliable similarity between these two rodents and were confirmed by quantitative RT-PCR. Our findings provide evidence that cross-species analysis can be a useful tool to study gene expression profiles of related organisms for which species-specific microarrays are not available.

Algorithms↗

GAPP: a fully automated software for the confident identification of human peptides from tandem mass spectra.

This paper introduces the genome annotating proteomic pipeline (GAPP), a totally automated publicly available software pipeline for the identification of peptides and proteins from human proteomic tandem mass spectrometry data. The pipeline takes as its input a series of MS/MS peak lists from a given experimental sample and produces a series of database entries corresponding to the peptides observed within the sample, along with related confidence scores. The pipeline is capable of finding any peptides expected, including those that cross intron-exon boundaries, and those due to single nucleotide polymorphisms (SNPs), alternate splicing, and post-translational modifications (PTMs). GAPP can therefore be used to re-annotate genomes, and this is supported through the inclusion of a Distributed Annotation System (DAS) server, which allows the peptides identified by the pipeline to be displayed in their genomic context within the Ensembl genome browser. GAPP is freely available via the web, at www. gapp.info.

Alternative Splicing↗

Prospects for clinical application of electronic-nose technology to early detection of Mycobacterium tuberculosis in culture and sputum.

Ziehl-Neelsen (ZN) staining for the diagnosis of tuberculosis (TB) is time-consuming and operator dependent and lacks sensitivity. A new method is urgently needed. We investigated the potential of an electronic nose (EN) (gas sensor array) comprising 14 conducting polymers to detect different Mycobacterium spp. and Pseudomonas aeruginosa in the headspaces of cultures, spiked sputa, and sputum samples from 330 culture-proven and human immunodeficiency virus-tested TB and non-TB patients. The data were analyzed using principal-component analysis, discriminant function analysis, and artificial neural networks. The EN differentiated between different Mycobacterium spp. and between mycobacteria and other lung pathogens both in culture and in spiked sputum samples. The detection limit in culture and spiked sputa was found to be 1 x 10(4) mycobacteria ml(-1). After training of the neural network with 196 sputum samples, 134 samples (55 M. tuberculosis culture-positive samples and 79 culture-negative samples) were used to challenge the model. The EN correctly predicted 89% of culture-positive patients; the six false negatives were the four ZN-negative and two ZN-positive patients. The specificity and sensitivity of the described method were 91% and 89%, respectively, compared to culture. At present, the reasons for the false negatives and false positives are unknown, but they could well be due to the nonoptimized system used here. This study has shown the ability of an electronic nose to detect M. tuberculosis in clinical specimens and opens the way to making this method a rapid and automated system for the early diagnosis of respiratory infections.

Biosensing Techniques↗

Genome annotating proteomics pipelines: available tools.

Proteomics based on tandem mass spectrometry is a powerful tool for identifying novel biomarkers and drug targets. Previously, a major bottleneck in high-throughput proteomics has been that the computational techniques needed to reliably identify proteins from proteomic data lagged behind the ability to collect the immense quantity of data generated. This is no longer the case, as fully automated pipelines for peptide and protein identification exist, and these are publicly and privately accessible. Such pipelines can automatically and rapidly generate high-confidence protein identifications from large datasets in a searchable format covering multiple experimental runs. However, the main challenge for the community now is to use these resources as they are, by taking full advantage of the pooling of information, so that the next barrier in our understanding of biology may be broken. There are currently two pipelines in the public domain that provide such potential: PeptideAtlas and the Genome Annotating Proteomic Pipeline. This review will introduce their features in the context of high-throughput proteomics, and provide indicative results as to their usefulness and usability through a side-by-side comparison of results obtained when processing a set of human plasma samples.

Animals↗

i-Tracker: for quantitative proteomics using iTRAQ.

BACKGROUND: iTRAQ technology for protein quantitation using mass spectrometry is a recent, powerful means of determining relative protein levels in up to four samples simultaneously. Although protein identification of samples generated using iTRAQ may be carried out using any current identification software, the quantitation calculations have been restricted to the ProQuant software supplied by Applied Biosciences. i-Tracker software has been developed to extract reporter ion peak ratios from non-centroided tandem MS peak lists in a format easily linked to the results of protein identification tools such as Mascot and Sequest. Such functionality is currently not provided by ProQuant, which is restricted to matching quantitative information to the peptide identifications from Applied Biosciences' Interrogator software. RESULTS: i-Tracker is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems. CONCLUSION: i-Tracker allows quantitative information gained using the iTRAQ protocol to be linked with peptide identifications from popular tandem MS identification tools and hence is both a timely and useful tool for the proteomics community.

Algorithms↗

Determination of partial amino acid composition from tandem mass spectra for use in peptide identification strategies.

We demonstrate a new approach to the determination of amino acid composition from tandem mass spectrometrically fragmented peptides using both experimental and simulated data. The approach has been developed to be used as a search-space filter in a protein identification pipeline with the aim of increased performance above that which could be attained by using immonium ion information. Three automated methods have been developed and tested: one based upon a simple peak traversal, in which all intense ion peaks are treated as being either a b- or y-ion using a wide mass tolerance; a second which uses a much narrower tolerance and does not perform transformations of ion peaks to the complementary type; and the unique fragments method which allows for b- or y-ion type to be inferred and corroborated using a scan of the other ions present in each peptide spectrum. The combination of these methods is shown to provide a high-accuracy set of amino acid predictions using both experimental and simulated data sets. These high quality predictions, with an accuracy of over 85%, may be used to identify peptide fragments that are hard to identify using other methods. The data simulation algorithm is also shown post priori to be a good model of noiseless tandem mass spectrometric peptide data.

Algorithms↗

Protein and peptide identification algorithms using MS for use in high-throughput, automated pipelines.

Current proteomics experiments can generate vast quantities of data very quickly, but this has not been matched by data analysis capabilities. Although there have been a number of recent reviews covering various aspects of peptide and protein identification methods using MS, comparisons of which methods are either the most appropriate for, or the most effective at, their proposed tasks are not readily available. As the need for high-throughput, automated peptide and protein identification systems increases, the creators of such pipelines need to be able to choose algorithms that are going to perform well both in terms of accuracy and computational efficiency. This article therefore provides a review of the currently available core algorithms for PMF, database searching using MS/MS, sequence tag searches and de novo sequencing. We also assess the relative performances of a number of these algorithms. As there is limited reporting of such information in the literature, we conclude that there is a need for the adoption of a system of standardised reporting on the performance of new peptide and protein identification algorithms, based upon freely available datasets. We go on to present our initial suggestions for the format and content of these datasets.

Algorithms↗

Confident protein identification using the average peptide score method coupled with search-specific, ab initio thresholds.

Perhaps the greatest difficulty in interpreting large sets of protein identifications derived from mass spectrometric methods is whether or not to trust the results. For such experiments, the level of confidence in each protein identification made needs to be far greater than the often used 95% significance threshold to avoid the identification of many false-positives. To provide higher confidence results, we have developed an innovative scoring strategy coupling the recently published Average Peptide Score (APS) method with pre-filtering of peptide identifications, using a simple peptide quality filter. Iterative generation of these filters in conjunction with reversed database searching is used to determine the correct levels at which the APS and peptide quality thresholds should be set to return virtually zero false-positive reports. This proceeds without the need to reference a known dataset.

Computational Biology↗

Monitoring haemodialysis using electronic nose and chemometrics.

An ever-increasing number of patients have to undergo regular renal dialysis to compensate for acute or chronic renal failure. The adequacy of the treatment has a profound effect on patients' morbidity and mortality. Therefore, it is necessary to assess the delivered dialysis dose. For the quantification of the dialysis dose, two parameters are most commonly used, namely the K(t)/V value (normalised dose of dialysis) and the urea reduction rate, yet the prescribed dialysis dose often differs from the actual delivered dialysis dose. Currently, no interactive process is available to ensure optimal treatment. The aim of this study was to investigate the potential for an "electronic nose" as a novel monitoring tool for haemodialysis. Blood samples were analysed using an electronic nose, comprising an array of 14 conducting polymer sensors, and compared to traditional biochemistry. Principal component analysis and hierarchical cluster analysis were applied to evaluate the data, and demonstrated the ability to distinguish between pre-dialysis blood from post-dialysis blood independent of the method used. It is concluded that the electronic nose is capable of discriminating pre-dialysis from post-dialysis blood and hence, together with an appropriate classification model, suitable for on-line monitoring.

Algorithms↗

Simultaneous quantification of analytes in quaternary mixtures using dual pulse staircase voltammetry and genetically optimised neural networks.

This paper describes the simultaneous quantification of four aliphatic compounds (ethanol, methanol, fructose and glucose) mixed in varying concentrations. The method used employs dual pulse staircase voltammetry (DPSV) to acquire an electrochemical voltammogram from the mixture. An artificial neural network, optimised using an elitist genetic algorithm, is then used to determine the concentration of each individual analyte from the voltammogram. The best average RMS errors achieved when testing with unseen data were 5.03%, 7.72%, 3.29% and 4.00% for maximum analyte concentrations of ethanol, methanol, fructose and glucose respectively. This work represents an important step forward because DPSV data is notoriously difficult to calibrate due to complex electrode-analyte interactions, and had not previous been shown to be amenable to quaternary mixtures.

Alcohols↗

Identification of oil contaminants on polymer coated beverage cans using fluorescence spectroscopy.

In a recent publication we introduced a novel method for detection of impurities on beverage can surfaces using Raman spectroscopy. While investigating the technique, limitations emerged due to the low sensitivity of Raman scatter. This is a particular problem with the largest contributor of impurities in beverage cans: lubricants employed in the manufacturing process. This paper presents an alternative approach, using the more sensitive technique of fluorescence spectroscopy to tackle the same problem. Measurements using fluorescence spectroscopy were conducted indirectly in a cuvette as well as directly on a can surface with the aid of fiber optics. The chemometrics methods of linear discriminant analysis (LDA) and principal components analysis (PCA) were used to classify acquired spectra as belonging to one of the 16 investigated lubricants. Fiberoptic scans revealed that a successful detection and recognition of lubricant is possible down to a volume of 0.5 microL deposited on the can surface. Contaminant detection was possible at even lower levels down to 0.01 microL, but reliable identification proved difficult at such low volumes. Indirect measurements of lubricants dissolved in cyclohexane yielded the lowest detection limits between 1-0.1 ppb.

Beverages↗

Principal components analysis for the visualisation of multidimensional chemical data acquired by scanning Raman microspectroscopy.

Raman microspectroscopy is ideally suited to surface analysis as it allows detailed chemical information to be acquired from surfaces at a relatively high spatial resolution (typically 1 microm). Using a motorised sample table or probe, it is possible to raster scan a surface to obtain spatially resolved chemical information. Visualisation of the acquired data is a problem, however, as the spectrum acquired at each point can contain several hundred individual intensity measurements. Existing visualisation methods are limited to plotting each scanned point with an intensity determined from the measured intensity at a single wavenumber, or the similarly between the point's spectrum and a reference spectrum. Such methods are wasteful as a lot of acquired information is discarded, and results are prone to misinterpretation due to background variance and instrumental noise. In this paper we introduce a new method that uses principal components analysis (PCA) to reduce the spectrum at each point to three factors that are then used to define the red, green and blue components of the corresponding point on a false colour map. To increase the effective resolution, interpolation is used to approximate the colours corresponding to points between those actually scanned. To demonstrate the technique, the internal surface of a beverage can, contaminated with a 40 microm diameter carbonised oven impurity, consisting mainly of sp2- and sp3-hybridised saturated carbon bonds, has been used as a case study.

Beverages↗