PubMed Health⌕ Search

Biomedical subjects

Constance M Murphy

Publications and source records attributed to Constance M Murphy.

7 recordsLinked to original sources

Determination of methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, 2-ethyl-5-methyl-3,3-diphenylpyraline and methadol in meconium by liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry.

This paper details a validated liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI-MS/MS) method for the quantification of methadone, and its metabolites 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), 2-ethyl-5-methyl-3,3-diphenylpyraline (EMDP) and methadol in human meconium. Limits of detection (LOD) were determined to be 1.0 ng/g for methadone, EDDP and EMDP and 2.5 ng/g for methadol. The limits of quantitation (LOQ) for methadone, EDDP, EMDP were 5 and 25 ng/g for methadol. Linearity ranged from 5.0 to 500 ng/g. Following solid-phase extraction, no matrix effect was observed. This method proved to be suitable for the quantification of methadone, EDDP and EMDP and the semi-quantitation of methadol in meconium. Literature review revealed no other published LC-APCI-MS/MS method for the detection of methadone and its three main metabolites in meconium specimens.

Atmospheric Pressure↗

Liquid chromatographic/electrospray ionization tandem mass spectrometric analysis for the quantification of buprenorphine, norbuprenorphine, buprenorphine-3-beta-D-glucuronide and norbuprenorphine-3-beta-D-glucuronide in human plasma.

A liquid chromatographic/electrospray ionization tandem mass spectrometric method for the quantification of the synthetic opiate buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-3-beta-D-glucuronide (BUP-3-G) and norbuprenorphine-3-beta-D-glucuronide (NBUP-3-G) in human plasma was developed and validated. Identification and quantification were based on the following transitions: m/z 468 to 396 and 414 for BUP, m/z 414 to 326 and 340 for NBUP, m/z 644 to 468 for BUP-3-G and m/z 590 to 414 for NBUP-3-G. Calibration by linear regression analysis utilized deuteratated internal standards and a weighting factor of 1/x. The method was accurate and precise across a linear dynamic range of 0.6-50.0 ng ml(-1). Pretreatment of plasma samples using solid-phase extraction was sufficient to limit matrix suppression to <30% for all four analytes. The method proved to be suitable for the quantification of BUP and the related metabolites in plasma samples collected from BUP-maintained study participants.

Buprenorphine↗

LC-ESI-MS/MS analysis for the quantification of morphine, codeine, morphine-3-beta-D-glucuronide, morphine-6-beta-D-glucuronide, and codeine-6-beta-D-glucuronide in human urine.

A liquid chromatographic-electrospray ionization-tandem mass spectrometric method for the quantification of the opiates morphine, codeine, and their metabolites morphine-3-beta-D-glucuronide (M-3-G), morphine-6-beta-D-glucuronide (M-6-G) and codeine-6-beta-D-glucuronide (C-6-G) in human urine has been developed and validated. Identification and quantification were based on the following transitions: 286 to 201 and 229 for morphine, 300 to 215 and 243 for codeine, 462 to 286 [corrected] for M-3-G, 462 to 286 for M-6-G, and 476 to 300 for C-6-G. Calibration by linear regression analysis utilized deuterated internal standards and a weighting factor of 1/X. The method was accurate and precise across a linear dynamic range of 25.0 to 4000.0 ng/ml. Pretreatment of urine specimens using solid phase extraction was sufficient to limit matrix suppression to less than 40% for all five analytes. The method proved to be suitable for the quantification of morphine, codeine, and their metabolites in urine specimens collected from opioid-dependent participants enrolled in a methadone maintenance program.

Calibration↗

LC-atmospheric pressure chemical ionization-MS/ MS analysis of multiple illicit drugs, methadone, and their metabolites in oral fluid following protein precipitation.

A quantitative LC-APCI-MS/MS method for simultaneous determination of multiple illicit drugs, methadone, and their metabolites in oral fluid was developed and validated. Sample pretreatment was limited to acetonitrile protein precipitation. LC separation was performed in 25.5 min, with a total analysis time of 35 min. Identification and quantitation were based on selected reaction monitoring. Calibration by linear regression analysis utilized deuterated internal standards and a weighing factor 1/x. Limits of detection and lower limits of quantitation (LOQ) were established between 0.25 and 5 ng/ mL and 0.5-10 ng/mL, respectively. linearity was obtained with an average correlation coefficient (R2) of >0.99, over a dynamic range from the LOQ up to maximum 500 ng/mL The method demonstrated good accuracy, intra- and interbatch precision, recovery, and stability for all compounds. No oral fluid matrix effect was observed throughout the chromatographic run. Protein precipitation provided a fast and simple sample pretreatment, while LC-APCI-MS/MS proved to be a sensitive and rugged quantitative method for multiple illicit and legal drugs in oral fluid. The method proved to be suitable for the evaluation of oral fluid as an alternative matrix to urine for monitoring illicit drug use and for determining oral fluid methadone concentrations in pregnant opiate and/or cocaine addicts.

Humans↗

Urine drug testing for opioids, cocaine, and metabolites by direct injection liquid chromatography/tandem mass spectrometry.

A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantification of opioids, cocaine, and metabolites in urine was developed and validated. A 10-microL aliquot of urine was injected directly onto the LC/MS/MS system. The lack of sample preparation substantially reduced total analysis time. Separation was performed by reversed-phase chromatography with gradient elution for all analytes in 26 min. Atmospheric pressure chemical ionization (APCI) was a rugged and efficient ionization technique for basic drugs. Identification and quantification was based on selected reaction monitoring (SRM). Calibration, with deuterated internal standards, was performed by linear regression analysis (weighting factor 1/x). Limits of quantitation (LOQ) were established between 10-100 ng/mL and linearity was obtained up to a maximum of 10 000 ng/mL with an average correlation coefficient (R(2)) > 0.99. Analytical validation criteria for specificity, precision, accuracy, dilution integrity, matrix effect, and stability were fulfilled. The method proved to be simple and time efficient, and was applicable for illicit drug use monitoring and methadone treatment compliance in clinical research projects at the National Institute on Drug Abuse (NIDA).

Calibration↗

Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: influence of ionization type, sample preparation, and biofluid.

The purpose of the present work was to evaluate the synergistic effect of ionization type, sample preparation technique, and bio-fluid on the presence of matrix effect in quantitative liquid chromatography (LC)-MS/MS analysis of illicit drugs by post-column infusion experiments with morphine (10-microg/mL solution). Three bio-fluids (urine, oral fluid, and plasma) were pretreated with four sample preparation procedures [direct injection, dilution, protein precipitation, solid-phase extraction (SPE)] and analyzed by both LC-electrospray ionization (ESI)-MS/MS and LC-atmospheric pressure chemical ionization (APCI)-MS/MS. Our results indicated that both ionization types showed matrix effect, but ESI was more susceptible than APCI. Sample preparation could reduce (clean up) or magnify (pre-concentrate) matrix effect. Residual matrix components were specific to each bio-fluid and interfered at different time points in the chromatogram. We evaluated matrix effect in an early stage of method development and combined optimal ionization type and sample preparation technique for each bio-fluid. Simple dilution of urine was sufficient to allow for the analysis of the analytes of interest by LC-APCI-MS/MS. Acetonitrile protein precipitation provided both sample clean up and concentration for oral fluid analysis, while SPE was necessary for extensive clean up of plasma prior to LC-APCI-MS/MS.

Analgesics, Opioid↗

Preparative separation of isomeric sulfophthalic acids by conventional and pH-zone-refining counter-current chromatography.

Two modes of high-speed counter-current chromatography (HSCCC) were applied to separate 3- and 4-sulfophthalic acid from a mixture. Conventional HSCCC was useful for the separation of up to several hundred milligram quantities of these positional isomers, while pH-zone-refining CCC was implemented successfully to separations at the multigram level. The conventional HSCCC separations were performed with a standard J-type HSCCC system that has a superior resolution but a lower level of retention of the stationary phase of the biphasic solvent system used (acidified n-butanol-water). The pH-zone-refining CCC separations were performed with an X-type HSCCC system (a cross-axis system) that has a higher capability for retention of the stationary phase. The purified positional isomers (over 99% pure as determined by HPLC) were characterized by 1H NMR and negative ion electrospray ionization mass spectrometry.

Chromatography, High Pressure Liquid↗