PubMed Health⌕ Search

Biomedical subjects

Constantinos A Georgiou

Publications and source records attributed to Constantinos A Georgiou.

3 recordsLinked to original sources

Synchronous fluorescence spectroscopy for quantitative determination of virgin olive oil adulteration with sunflower oil.

Adulteration of extra virgin olive oil with sunflower oil is a major issue for the olive oil industry. In this paper, the potential of total synchronous fluorescence (TSyF) spectra to differentiate virgin olive oil from sunflower oil and synchronous fluorescence (SyF) spectra combined with multivariate analysis to assess the adulteration of virgin olive oil are demonstrated. TSyF spectra were acquired by varying the excitation wavelength in the region 270-720 nm and the wavelength interval (Deltalambda) in the region from 20 to 120 nm. TSyF contour plots for sunflower, in contrast to virgin olive oil, show a fluorescence region in the excitation wavelength range 325-385 nm. Fifteen different virgin olive oil samples were adulterated with sunflower oil at varying levels (0.5-95%) resulting in one hundred and thirty six mixtures. The partial least-squares regression model was used for quantification of the adulteration using wavelength intervals of 20 and 80 nm. This technique is useful for detection of sunflower oil in virgin olive oil at levels down to 3.4% (w/v) in just two and a half minutes using an 80-nm wavelength interval.

Olive Oil↗

Rapid, fully automated flow injection antioxidant capacity assay.

A flow injection method for antioxidant capacity assessment based on a low-cost laboratory-made analyzer is reported. A sample of 30 microL is injected in acetate buffer stream, pH 4.6, that converges with ABTS*(+) reagent stream. Detection is achieved by monitoring absorbance at 414 nm. The proposed method achieves a sample throughput of up to 120 samples h(-1), the detection limit being 1.3 microM trolox. Precision was better than 5% relative standard deviation (n = 4) and the linear range was 4-100 microM, expanded to 250 microM trolox utilizing concentration gradients formed along the injected sample bolus. Information on reaction kinetics is obtained through a single injection. The method was applied to pure compounds and wine and honey samples. Good correlation was found between antioxidant capacity assessed through the proposed method and phenolic content: r = 0.94 for red wines, r = 0.96 for white and rose wines, and r = 0.89 for honeys.

Antioxidants↗

Rapid, noninvasive quantitative determination of acyclovir in pharmaceutical solid dosage forms through their poly(vinyl chloride) blister package by solid-state Fourier transform Raman spectroscopy.

Fourier transform (FT) Raman spectroscopy based on band intensity or band area measurements was used for the quantitative determination of acyclovir in pharmaceutical solid dosage forms through their poly(vinyl chloride) blister package. Univariate calibration using the bands observed at 1690, 1630, 1574, 1482, 1181, 578, and 508 cm(-1) was found to be sufficient for the analysis. Calibration curves were linear, the correlation coefficients being 0.997-0.9993 and 0.996-0.9991 for band intensity and band area measurements, respectively. Results obtained compare well, as indicated by the t-test, with those obtained by the current United States Pharmacopoeia (USP 24) and National Formulary (NF 19) method. Precision ranged from 0.7-4.5 and 0.4-4.0% RSD (n = 3) for band intensity and band area measurements, respectively. The developed nondestructive FT-Raman method is rapid, simple, and can be used for the on-line, real-time monitoring of acyclovir formulation production lines.

Acyclovir↗