JPEG2000 compression of thin-section CT images of the lung: effect of compression ratio on image quality.

PURPOSE: To assess retrospectively the effect of the Joint Photographic Experts Group 2000 (JPEG2000) compression ratio on the quality of thin-section computed tomographic (CT) images. MATERIALS AND METHODS: In this institutional review board-approved investigation (protocol 238/2004), thin-section CT images were subjected to irreversible JPEG2000 compression by using five compression ratios (3:1, 5:1, 7:1, 9:1, and 11:1). Three radiologists independently evaluated 60 thin-section CT images, of various diseases, that were obtained with single-detector (weighted dose index, 14.4 mGy) and multidetector (weighted dose index, 9.8 mGy) CT. Toggling between the original and compressed images, readers had to identify the original image by using a forced-choice two-alternative model and to subjectively rank the quality of what they believed to be the compressed image. To assess the reader's ability to distinguish the compressed from the original image, a binomial test was used. Bonferroni correction was applied for all multiple tests. RESULTS: Images compressed with a ratio of 3:1 were not distinguishable from original images (P > .2 for all readers). With use of the 5:1 ratio, minor differences in appearance between the compressed and original images were seen by one of the three readers. With use of higher compression ratios (>/=7:1), all readers (P < .001) recognized the original image. The quality of more than 90% of the images compressed with a 7:1 or higher ratio was substantially degraded. Single-detector and multidetector CT results were not significantly different. CONCLUSION: The highest ratio that yielded visually lossless compression of thin-section CT images was 3:1. With the 5:1 ratio, there was minor image quality loss, while use of higher compression ratios (>/=7:1) caused substantial degradation of image quality and potential loss of diagnostic information.

Adult↗

Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography.

The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality.

Adult↗

Occult scaphoid fractures: comparison of multidetector CT and MR imaging--initial experience.

PURPOSE: To compare the diagnostic performance of multidetector computed tomography (CT) and magnetic resonance (MR) imaging in patients clinically suspected of having a scaphoid fracture and who had normal initial radiographs, with radiographs obtained 6 weeks after trauma as the reference standard. MATERIALS AND METHODS: The ethics committee approved the study, and all patients gave written informed consent. Twenty-nine patients (17 male, 12 female; age range, 17-62 years; mean age, 34 years +/- 13) underwent multidetector CT and MR imaging within 6 days after trauma. CT data were obtained with 0.5-mm collimation. For image review, 0.7-mm-thick multiplanar reformations were performed in transverse, coronal, and sagittal planes relative to the wrist. The 1.0-T MR examination consisted of coronal and transverse short inversion time inversion-recovery, coronal and transverse T1-weighted spin-echo, and coronal volume-rendered T2-weighted gradient-echo sequences. Two radiologists analyzed the CT and MR images. A binomial test was used to evaluate the significance of the differences between MR imaging and CT in detection of scaphoid fractures and cortical involvement (P < .05). RESULTS: The 6-week follow-up radiographs depicted a scaphoid fracture in 11 (38%) patients. Eight patients had a cortical fracture, while three patients had only a bandlike lucency within the trabecular portion of the scaphoid. MR imaging depicted all 11 fractures but only three [corrected] cortical fractures. Multidetector CT depicted all eight cortical fractures but failed to depict trabecular fractures. No false-positive fractures were seen on MR or CT images. Differences between MR imaging and CT were not significant for the detection of scaphoid fractures (P = .25) but were significant for cortical involvement (P = .03). CONCLUSION: Multidetector CT is highly accurate in depicting occult cortical scaphoid fractures but appears inferior to MR imaging in depicting solely trabecular injury. MR imaging is inferior to multidetector CT in depicting cortical involvement.

Adolescent↗

Unenhanced multi-detector row CT in patients suspected of having urinary stone disease: effect of section width on diagnosis.

PURPOSE: To assess prospectively the effect of section width in multi-detector row computed tomographic (CT) evaluation of patients with acute flank pain who are suspected of having or known to have urinary stone disease. MATERIALS AND METHODS: This study was approved by the ethics committee of the authors' university, and written informed consent was obtained from all patients. One hundred forty-seven patients (age range, 11-101 years; mean, 51.4 years +/- 18.7 [standard deviation]) suspected of having urinary stone disease underwent unenhanced multi-detector row CT. CT was performed with four detector rows, a section thickness of 1.0 mm, an effective tube current-time product of 100 mAs, and a tube voltage of 120 kVp (CT dose index, 11.4 mGy). From these data, three sets of transverse images were reconstructed with section widths of 1.5, 3.0, and 5.0 mm and approximately 50% of overlap each. Scans were evaluated in varying random orders by two radiologists for the number, size, and location of uroliths and nephroliths and for the presence of phleboliths, renal cysts, and secondary signs of obstruction. The significance of differences between the numbers of detected calcifications and the numbers of associated abnormalities on the scans obtained with varying section widths was tested with the McNemar test at a P level of less than .05. Spearman rho rank correlation coefficients were calculated to assess the correlation between the presence of uroliths and the presence of secondary signs. RESULTS: Uroliths were found in 72 of 147 (49.0%) patients, and nephroliths were found in 16 patients (10.9%). There was no significant difference between section widths of 1.5 and 3.0 mm with regard to the number of detected stones (264 uroliths and 61 nephroliths for both protocols). Transverse sections 5.0-mm wide revealed significantly fewer uroliths (n = 231; P < .001) and nephroliths (n = 47; P < .016). The final diagnosis was changed in four of 72 patients. All missed renal and ureteral stones measured less than 3 mm in diameter. CONCLUSION: Overlapping 3-mm sections are sufficient for the detection of urinary stone disease. Small calculi (<3 mm) may be missed on 5.0-mm-thick sections.

Adolescent↗

MDCT for the diagnosis of acute pulmonary embolism.

With the advent of multidetector CT, pulmonary CT angiography (MD-CTPA) has substantially gained in spatial resolution and is the accepted method of choice to diagnose and rule out acute pulmonary embolism down to the subsegmental level. This article reviews means to optimize scanning technique and contrast injection protocols dependent on the scanner type used. It summarizes recent publications on the performance of MD-CTPA with special emphasis on the diagnostic accuracy, interpretation and clinical role of (isolated) peripheral emboli. Diagnostic algorithms are outlined that describe the role of CT in context with the pretest probability, the D-Dimer, lower limb sonography and scintigraphy.

Acute Disease↗

Pulmonary infections in the late period after allogeneic bone marrow transplantation: chest radiography versus computed tomography.

PURPOSE: To analyze the capabilities of chest roentgenogram (CXR) and computed tomography (CT) in the evaluation of pulmonary infectious disease in the late period (>100 days) after allogeneic bone marrow transplantation (BMT). METHODS: Ninety-four matched CXR and CT examinations were performed for clinical suspicion of infectious lung disease. The time gap between CXR and CT was 48 h at maximum. The image pairs were correlated with the patients' clinical course and with the results of diagnostic bronchoalveolar lavage (BAL). An unremarkable clinical course over the subsequent seven days after imaging and/or negative microbiological culture served as the basis for excluding infectious lung disease. Positive microbiological culture and/or improvement of symptoms after antibiotic therapy were considered as evidence of infectious disease. RESULTS: The correlation with the clinical course and/or BAL revealed a significantly higher sensitivity, negative predictive value, and accuracy for CT than for CXR (89% versus 58%, P < 0.0001; 78% versus 47%, P < 0.0001; 90% versus 68%, P < 0.0001, respectively). CT was significantly more diagnostic in BAL verified fungal and bacterial infections (P < 0.05). CONCLUSION: CT is significantly superior to CXR in the evaluation of infectious pulmonary disease in the late phase after BMT. Therefore, an unremarkable CXR should be followed by a CT scan to reliably detect or to accurately exclude early pulmonary infection in these patients.

Adolescent↗

Soft-copy reading of digital chest radiographs: effect of ambient light and automatic optimization of monitor luminance.

OBJECTIVE: We sought to evaluate whether soft-copy reading of simulated pulmonary chest lesions is influenced by ambient light and automatic optimization of cathode ray tube (CRT) monitor luminance. MATERIALS AND METHODS: Four types of simulated lesions (nodules, lines, micronodules, and patchy opacities) were superimposed over an anthropomorphic chest phantom. Lesion detection with soft-copy reading was assessed using a high-contrast grayscale 2K CRT monitor under the following conditions: (1) subdued lighting (<50 lux); (2) normal lighting conditions (450 lux) without, and (3) with a sensitivity modulation to automatically adjust the CRT luminance to the increased amount of ambient light. Reading data were analyzed according to receiver operating curve. Significance of differences was tested using an analysis of variance for repeated measures. RESULTS: Ambient room light of 450 lux did not significantly influence the detection of nodules and patchy opacities. However, bright ambient light significantly decreased detection of micronodules (0.60 vs. 0.74) and lines (0.52 vs. 0.66) relative to subdued lighting conditions. Automatic luminance adjustment could compensate the effect of ambient light for the micronodules (0.77) but not for the lines (0.53). CONCLUSION: Bright ambient light significantly decreases detection of small low-contrast structures. This may be partially but not completely compensated by an automatic luminance adaptation.

Data Display↗

Computed radiography and direct radiography: influence of acquisition dose on the detection of simulated lung lesions.

PURPOSE: We sought to evaluate the performance of dual-readout and single-readout computed radiography compared with direct radiography for detecting subtle lung abnormalities with a standard and a low-dose technique. MATERIALS AND METHODS: Posteroanterior radiographs of an anthropomorphic chest phantom were obtained with a single-readout storage phosphor radiography system (CRS, pixel size 200 microm), a dual-readout storage phosphor radiography system (CRD, pixel size 100 microm), and a direct detector (DR, pixel size 143 microm) at dose levels of 400 and 800 speed. Ten templates were superimposed to project 4 types of lesions over low- and high-attenuation areas, simulating nodules, micronodules, lines, and patchy opacities. Six radiologists evaluated 60 hard-copy images for the presence or absence of lesions. Statistical significance of differences was evaluated using receiver operating characteristic analysis and analysis of variance. RESULTS: For both low- and high-attenuation areas, CRD (Az = 0.85 and 0.66) was superior to CRS (Az = 0.75 and 0.58) for overall performance and all lesion subtypes (P < 0.05). DR (Az = 0.87 and 0.67) performed slightly better than CRD, being significant only for the detection of micronodules. Acquisition dose significantly affected only the detection of lines and micronodules, whereas the detection of nodules and patchy opacities was not significantly different with reduced exposure, regardless of the system used. CONCLUSION: The dual-readout CR system significantly outperformed the single-readout CR and almost equaled the performance of DR. Dose reduction was more critical for small-sized lesions (micronodules, lines) than for nodular or patchy opacifications and affected mainly the lesions in high attenuation areas.

Humans↗

Flat-panel-detector chest radiography: effect of tube voltage on image quality.

PURPOSE: To compare the visibility of anatomic structures in direct-detector chest radiographs acquired with different tube voltages at equal effective doses to the patient. MATERIALS AND METHODS: The study protocol was approved by the institutional internal review board, and written informed consent was obtained from all patients. Posteroanterior chest radiographs of 48 consecutively selected patients were obtained at 90, 121, and 150 kVp by using a flat-panel-detector unit that was based on cesium iodide technology and automated exposure control. Monte Carlo simulations were used to verify that the effective dose for all kilovoltage settings was equal. Five radiologists subjectively and independently rated the delineation of anatomic structures on hard-copy images by using a five-point scale. They also ranked image quality in a blinded side-by-side comparison. Average ranking scores were compared by using one-way analysis of variance with repeated measures. Data were analyzed for the entire patient group and for two patient subgroups that were formed according to body mass index (BMI). RESULTS: The visibility scores of most anatomic structures were significantly superior with the 90-kVp images (mean score, 3.11), followed by the 121-kVp (mean score, 2.95) and 150-kVp images (mean score, 2.80). Differences did not reach significance (P > .05) only for the delineation of the peripheral vessels, the heart contours, and the carina. This was also true for the subgroup of patients (n = 24) with a BMI greater than and the subgroup of patients (n = 24) with a BMI less than the mean BMI (26.9 kg/m(2)). At side-by-side comparison, the readers rated 90-kVp images as having superior image quality in the majority of image triplets; the percentage of 90-kVp images rated as "first choice" ranged from 60% (29 of 48 patients) to 90% (43 of 48 patients), with a median of 88% (42 of 48 patients), among the readers. CONCLUSION: Delineation of most anatomic structures and overall image quality were ranked superior in digital radiographs acquired with lower kilovoltage at a constant effective patient dose.

Aged↗

Detectability of small and flat polyps in MDCT colonography using 2D and 3D imaging tools: results from a phantom study.

OBJECTIVE: The objective of this phantom study was to determine the performance of MDCT colonography for the detection of small polyps under ideal imaging conditions and to determine the added value of 3D imaging when used as an adjunct to 2D imaging. MATERIALS AND METHODS: Thirty-six polypoid and 39 flat polyps (44 lesions, 2-5 mm; 31 lesions, 6-8 mm) were placed in three explanted segments of a thoroughly cleaned porcine colon (overall length, 4.5 m) that was distended with air and submerged in a water phantom. MDCT data sets with 4 x 1 mm collimation and 6-mm table feed were reconstructed every 0.7 mm with 1.25-mm effective slice width. The data were reviewed by three radiologists using 2D images in all three projections and with 3D volume-rendered images available as an adjunct to the 2D images. RESULTS: Additional 3D as a problem-solving tool significantly increased the overall sensitivity (96% vs 90%), decreased the total number of false-positive calls (n = 9 vs n = 5), and increased the diagnostic confidence level (p < 0.03) compared with 2D images alone. Small polyps less than or equal to 5 mm (89% vs 95%, p = 0.004) and flat polyps (82% vs 94%, p = 0.001) especially benefited from 3D. Sensitivity was generally higher for polypoid than for flat polyps (99% vs 94%, p = 0.041). CONCLUSION: Under phantom conditions, simulating an ideal clinical setup, MDCT colonography is not limited by spatial resolution and detects polyps less than or equal to 5 mm in size with high sensitivity and specificity. Additional 3D image tools improve diagnostic accuracy and reviewer confidence, especially for the detection of flat and small polyps.

Animals↗

Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer preference study.

OBJECTIVE: Our objective was to compare cathode ray tube (CRT) display with liquid crystal display (LCD) for soft-copy viewing of chest radiographs in a clinical setting. MATERIALS AND METHODS: We displayed 80 posteroanterior digital chest radiographs side by side on a 5-megapixel CRT display and a 3-megapixel LCD. Gradation characteristics of both monitors were adjusted to DICOM display standards. Using a 4-point scale, seven radiologists ranked overall image quality and visibility of anatomic landmarks. Data analysis included Wilcoxon's rank sum test to assess the significance of preference for the different display modes and calculation of the percentage of images ranked equally by at least five of the seven radiologists. RESULTS: Wilcoxon's rank sum test found significant preferences (p < 0.001) for the CRT display for visualization of structures in low-attenuation areas of the thorax and for the LCD for visualization of structures in high-attenuation areas of the thorax. Overall image quality was ranked equal by at least five radiologists in 70% of cases, whereas for the remaining images a significant preference was found for the CRT display. CONCLUSION: We conclude that, under subdued ambient lighting conditions and without use of windowing, for most images the overall quality is equal with high-resolution CRT display and LCD. In images judged preferentially, we found a significant superiority for LCD for delineating mediastinal structures and for CRT display for delineating structures in the lung.

Computer Terminals↗

Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors.

PURPOSE: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode-ray tube (CRT) monitor in the detection of simulated support catheters on bedside chest radiographs. MATERIALS AND METHODS: The ethics committee did not require approval or patient informed consent when this study began. Because of a change in regulations, before images were acquired the nature of the study and procedures were explained to patients or their relatives, and consent was then obtained. A total of 131 catheter fragments (12-14 per radiograph) were superimposed over 10 anteroposterior bedside chest radiographs obtained with storage phosphor technology. Images were displayed on an LCD monitor (1536 x 2048 matrix) and a CRT monitor (2048 x 2560 matrix). Five radiologists independently located the catheter fragments and rated their confidence in detection with bright and subdued ambient light. A two-way analysis of variance and the Friedman test were used for statistical analysis. RESULTS: There was no significant difference for either display type with respect to correctly detected catheter fragments (mean sensitivity, 56.6% and 56.0% for the CRT and the LCD monitors, respectively, with bright light and 61.2% for both monitors with subdued light). With both display types, detection rate with bright light decreased significantly (P < .05). False-positive rates and confidence ratings were not significantly affected by monitor type or ambient light. CONCLUSION: In a study with simulation of clinical conditions, performance of the LCD monitor and high-resolution CRT monitor for detection of support catheters on bedside chest radiographs was equivalent. With both displays, detection performance was equally reduced with bright ambient light.

Aged↗

Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

The purpose of the study was to compare the detection performance of a cathode ray tube (CRT) monitor versus a liquid crystal display (LCD) monitor for simulated subtle pulmonary lesions. Ten templates containing simulated lung lesions were superimposed on an anthropomorphic chest phantom. Posteroanterior radiographs were obtained using flat panel technology and were displayed on a CRT and an LCD monitor. Image processing and reading conditions were equivalent for both softcopy displays. Five observers assessed lesion detectability using receiver-operating characteristic (ROC) methodology. A multivariate test (Pillai trace) was used to test the significance of differences (P<0.05). The multivariate test revealed significantly different detection rates for the lesion types, but no significant difference between the two display modes. Detection performance for both monitors was higher for nodules and micro-nodules and lower for lines and patchy opacities. Analysis of lesion subgroups according to their location in lucent/obscured lung areas was also not statistically significant. Under ideal reading conditions, CRT and LCD displays perform equivalently for the detection of simulated subtle pulmonary lesions.

Data Display↗

Comparison of an automatic versus a semiautomatic mode for gray-scale adaptation for digital chest radiography.

PURPOSE: To compare image quality of digital chest radiographs using 2 modes of gradation adjustment. METHODS: We compared image quality and visualization of anatomic landmarks of 50 chest radiographs after digital processing using a semiautomatic mode with a fixed gamma of 2.6 and an automatic mode with individual gamma adaptation. RESULTS: The mean gamma was significantly higher (P < 0.001) with the automatic mode (3.0 vs. 2.6, respectively). Patient constitution had no impact on the automatically adapted gamma for PA but showed a significant correlation (P < 0.001) for lateral images. For PA, there was a preference (P < 0.016) of the semiautomatic mode in heavier patients whereas no difference was seen in slim patients. For the lateral projection, there was a general preference (P = 0.001) of the automatic mode. CONCLUSION: For PA radiographs, the semiautomatic mode provides superior results for heavier patients without compromising the quality in slim patients. For lateral radiographs, the automatic mode provides generally superior results.

Adult↗

Skeletal applications for flat-panel versus storage-phosphor radiography: effect of exposure on detection of low-contrast details.

PURPOSE: To compare exposure requirements for similar detection performance with flat-panel detectors and the most recent generation of storage-phosphor plates in the simulated scatter of typical skeletal radiographic examinations. MATERIALS AND METHODS: A contrast-detail test object was covered with varying thicknesses of acrylic to simulate skeletal exposure conditions in the wrist, knee, and pelvis. Three series were obtained with increasing thicknesses of a simulated soft-tissue layer (5, 10, and 20 cm) and increasing tube voltage (50, 70, and 90 kVp). A fourth series was obtained with exposure conditions adapted to the phantom instructions (75 kVp). Images were acquired with a flat-panel detector (cesium iodide scintillator) and storage-phosphor plates at five exposure levels (speed class range, 100-1,600). Five readers evaluated 84 images to determine the threshold contrast of 12 lesion diameters (range, 0.25-11.1 mm). Statistical significance of differences between the two digital systems was assessed with two-way analysis of variance. RESULTS: A linear relationship was found between the number of detected lesions and the logarithm of exposure (R(2) > 0.98 for all series). On average, the flat-panel system required 45% less exposure than did the phosphor plates when 20-cm-thick acrylic was superimposed on the test object. Differences in exposure requirements were smaller with decreasing thicknesses of simulated soft-tissue layers and lower tube voltages (39% at 10 cm and 70 kVp, and 17% at 5 cm and 50 kVp). All differences were statistically significant. CONCLUSION: Flat-panel radiography provides improved contrast detectability and a potential for exposure reduction compared with those with storage-phosphor radiography. The best performance was achieved with conditions comparable to those for radiography of the trunk and lowest for conditions that simulate radiography of the extremities.

Bone and Bones↗

Misdiagnosis of pulmonary embolism in patients with allergic reaction--the importance of prior probability of disease.

Because pulmonary embolism (PE) and its treatment carry substantial risk of morbidity and mortality, accurate diagnosis is essential. We report two cases with allergic reactions, in which PE was suggested by routine ECG and D-dimer elevation and strengthened by spiral CT. Therapy with low-molecular-weight heparin was initiated and long-term anticoagulation was considered. As their histories did not reveal any predisposing factor to PE, the cases were re-evaluated. Elevation of D-dimer was now attributed to allergic reaction, ECG abnormalities were considered as constitutional, and findings from spiral CT attributed to breathing artifacts and partial-volume effects. The diagnosis of PE was therefore rejected and anticoagulant treatment discontinued without sequelae. These cases show the importance of determining clinical probability before ordering further diagnostic tests and critical interpretation of test results suggestive of PE, based on prior probability of the disease.

Adult↗

Digital radiography of the chest: detector techniques and performance parameters.

Substantial advances in detector technology characterize digital chest radiography. This article compares the various systems from a radiologist's point of view. Computed radiography (CR) is a well-established system that is robust, has good reproducibility, and is relatively inexpensive. Image quality has been continuously improved in recent years while the physical size of the readout units has been reduced and the throughput increased. CR is the only digital system that can be used for bedside chest radiographs. Improved detector properties and dual reading have made it a dose-efficient system. Although now widely available, a 4K image matrix does not appear to offer a general diagnostic improvement for imaging the chest. New developments with respect to detector composition and readout process can be expected in the future. Direct radiography (DR) is the common name for different technologies that are characterized by a direct readout matrix that covers the whole exposure area. Conversion of x-ray intensity into electric signals can either be direct (selenium-based systems) or indirect (scintillator/photodiode systems). Advantages of DR systems are a high image quality and the potential for dose reduction. The role of selenium radiography (Thoravision) has decreased after the advent of DR systems although this dedicated chest unit offers high image quality at 400 speed acquisition dose. Especially in a PACS environment, CR and DR systems will increasingly substitute for conventional radiography with advantages for CR for bedside chest radiographs and for DR for high-end chest stands.

Humans↗