PubMed Health⌕ Search

Biomedical subjects

Corrado Fondacone

Publications and source records attributed to Corrado Fondacone.

2 recordsLinked to original sources

Hemodynamics in off-pump surgery: normal versus compromised preoperative left ventricular function.

OBJECTIVE: Off-pump coronary surgery (OPCABG), avoiding cardiopulmonary bypass and cardioplegic arrest, seems to be a better choice in patients with poor baseline cardiac function. Since cardiocirculatory collapse could be induced by heart displacement in this group of patients at high risk, a greater pathophysiologic understanding of the hemodynamic derangements occurring in such patients is needed. METHODS: Twenty-eight elective OPCABG patients were evaluated for hemodynamic changes induced by heart displacement, using arterial thermodilution to measure cardiac output and global end-diastolic volume. Hemodynamic parameters were recorded: at baseline; during proper exposure and stabilization of each vessel; and at the end of surgery. Patients were divided into two groups, according to baseline ejection fraction (EF): group A (EF>30%; N=16), group B (EF< or =30%; N=12). RESULTS: Heart displacement induced a significant drop in the cardiac and stroke index, with a lesser decrease of mean arterial pressure because of raised systemic vascular resistance. Preload, measured as global end diastolic volume, significantly decreased in group A, while it remained unchanged or increased in group B. Linear regression between the preload index and left ventricular stroke work was significant only in group A. CONCLUSIONS: Patients with poor baseline cardiac function can well tolerate OPCABG. However, the pathophysiologic modifications underlying the hemodynamic changes are different compared to those in patients with good preoperative cardiac performance.

Aged↗

Midterm evaluation of the Sorin Bicarbon heart valve prosthesis: single-center experience.

BACKGROUND: The purpose of this study was to perform midterm evaluation of the clinical performance of the Sorin Bicarbon mechanical heart valve prosthesis. METHODS: From November 1992 to December 2002, 328 patients underwent isolated aortic (AVR; 156) or mitral (MVR; 172) valve replacement with the Sorin Bicarbon mechanical valve. Concomitant surgery was performed in 83 patients (25.2%). RESULTS: Total hospital mortality was 5.2%. Survival at 7 years was 79.5% for AVR and 82.4% for MVR. Kaplan-Meier freedoms from valve-related complications were as follows: thromboembolism 92.7% (AVR 94.8%, MVR 92.1%); bleeding 93% (AVR 91.9%, MVR 94.5%); nonstructural dysfunction 96.6% (AVR 94.7%; MVR 97.9%); endocarditis 97.7% (AVR 97.4%, MVR 98.1%); and reoperation 95.7% (AVR 96.6%, MVR 93.9%). Overall freedom from valve-related death was 93.2% (AVR 99.3%, MVR 91.2%). At the end of follow-up, 88.9% of survivors were in New York Heart Association class I or II. CONCLUSIONS: The Sorin Bicarbon valve is a satisfactory mechanical valve prosthesis with low mortality and morbidity and good functional results.

Actuarial Analysis↗