PubMed Health⌕ Search

Biomedical subjects

Cosima Jahnke

Publications and source records attributed to Cosima Jahnke.

14 recordsLinked to original sources

Experimental evaluation of the detectability of submillimeter atherosclerotic lesions in ex vivo human iliac arteries with ultrahigh-field (7.0 T) magnetic resonance imaging.

BACKGROUND: To evaluate the ability of ultrahigh-field magnetic resonance imaging (MRI) to accurately depict the composition of the human arterial vessel wall ex vivo and to detect early atherosclerotic lesion formation in comparison to histology. METHODS: Eight iliac artery specimens with low-grade atherosclerotic lesions obtained from human organ donors were studied. Three-dimensional, high-resolution MRI (spatial resolution: 79 x 79 x 109 microm) was performed using T1-, T2- and proton density (PD)-weightings (7.0 Tesla MR system, Bruker Pharmascan). A total of 36 MR slices and corresponding histological sections were matched for comparative evaluation of area measurements of lumen, media and adventitia and--if present--plaque size. Statistical correlation between histology and MR measurements was tested and a ROC-analysis was performed to determine the plaque size being predictive of correctly identifying atherosclerotic lesions with MRI. RESULTS: The areas of vessel lumen and media as measured on T1-, T2- and PD-weighted MR images showed a strong correlation with the corresponding histological measurements (r = 0.84 to r = 0.89; P < 0.01), however, a systematic overestimation of 34-41% was found. For the area of adventitia, only a moderate, though significant, correlation (r = 0.55 to r = 0.62; P < 0.01) could be demonstrated with a similar overestimation by MRI (38-43%). With T1-weighted MRI, sensitivity and specificity for the detection of plaques > 4.0 mm(2) were 79% and 91%, respectively. With T2- and PD-weighted MRI, however, sensitivity and specificity for the detection of plaques > 0.4 mm2 were 93% and 89%. CONCLUSIONS: In an experimental ex vivo setting, ultrahigh-field MRI of the human arterial vessel wall resulted in an accurate visualization of vessel wall composition when compared to histology and, thus, allowed for a quantitative assessment. T2- and PD-weighted MRI proved capable of reliably detecting submillimeter atherosclerotic lesions.

Atherosclerosis↗

Accelerated 4D dobutamine stress MR imaging with k-t BLAST: feasibility and diagnostic performance.

PURPOSE: To prospectively determine feasibility and diagnostic performance (with angiography as reference standard) of k-space and time (k-t) broad-use linear acquisition speed-up technique (k-t BLAST) cine imaging during dobutamine stress for identification of inducible cardiac wall motion abnormalities. MATERIALS AND METHODS: The study was conducted according to standards of the Charité and Virchow-Klinikum Ethics Committee. Patients gave written consent. Dobutamine stress magnetic resonance (MR) imaging was conducted in 65 patients (mean age, 63 years +/- 9 [standard deviation]; 49 men) with conventional cine steady-state free precession (SSFP). Accelerated four-dimensional (4D) k-t BLAST single-breath-hold imaging with complete left ventricular (LV) coverage was also performed at rest and during stress. For the cine SSFP and accelerated cine techniques, duration of imaging at rest and LV end-diastolic volume and ejection fraction were assessed. Segmental agreement for resting and inducible wall motion abnormalities was determined. In a subgroup (n = 40), direct comparison between SSFP and accelerated cine was performed for coronary stenosis detection. A paired Student t test was used to assess significance of continuous variables. Pearson correlation was used to test correlation between the techniques. Sensitivity, specificity, and diagnostic accuracy were calculated (standard definitions). For quantitative measurement of agreement, Cohen kappa was applied. RESULTS: For accelerated cine, imaging duration at rest was shortened by 40%. Correlations between cine SSFP and accelerated cine for LV parameters were 135 mL +/- 37 versus 129 mL +/- 31 (r = 0.89) for end-diastolic volume and 59% +/- 8 versus 58% +/- 7 (r = 0.95) for ejection fraction. kappa Values for segmental wall motion at rest and stress ranged from 0.77 to 0.91. Sensitivity, specificity, and diagnostic accuracy for coronary stenosis (>or=50%) detection based on arterial territory were 82%, 87%, and 86%, respectively, for cine SSFP and 82%, 86%, and 85%, respectively, for accelerated cine imaging. CONCLUSION: Accelerated 4D k-t BLAST wall motion imaging at rest and at dobutamine stress is rapid and feasible; LV measurements were nearly identical between the imaging approaches. Segmental wall motion analysis at rest and at stress show excellent agreement and reliable depiction of myocardial territories supplied by coronary arteries with 50% or more luminal narrowing.

Adult↗

[Striking a new path in medical education. CAMPUS, an interactive, case-based training system].

BACKGROUND AND PURPOSE: Computer-assisted teaching and learning tools offer new opportunities for improving education and training of medical professionals. CAMPUS represents a software for computer-based, problem-oriented learning. It is a case-based training system which provides the patient's history within a highly realistic, multimedia format. Thus, the interactive design is expected to challenge, test and improve the medical knowledge and the diagnostic skills of the students. The objective of the present study was to introduce CAMPUS as a computer-based learning tool and to present preliminary results with regard to acceptance and user-friendliness. METHODS: CAMPUS was evaluated by 52 students regarding quality and experienced learning success. A tutorial was conducted within separate, small-numbered groups of students, each working on one learning case. The virtual case started with a summary of the patient's leading symptoms. The students independently took the patient history and carried out the physical examination. Then, they were asked to suggest differential diagnoses, refer the patient to appropriate diagnostic examinations and were encouraged to choose adequate therapeutic strategies. Subsequently, the quality of CAMPUS and the subjective learning success were evaluated with a standardized questionnaire. RESULTS: Nearly all students described the user interface as visually attractive (51/52) and clearly structured (52/52). In particular, the students found the use of videos to be advantageous. A marked learning success was described by most students (46/52) and all students considered learning with CAMPUS to be effective. CONCLUSION: CAMPUS offers an innovative training program to improve medical education and to enhance conventional teaching methods efficiently.

Attitude of Health Personnel↗

Determination of interobserver variability for identifying inducible left ventricular wall motion abnormalities during dobutamine stress magnetic resonance imaging.

AIMS: To determine the interobserver variability for identifying inducible left ventricular (LV) wall motion abnormalities during high-dose dobutamine/atropine stress cardiovascular magnetic resonance (DSMR). METHODS AND RESULTS: Four readers from various institutions were supplied with the image data from 150 consecutive DSMR examinations and asked to grade wall motion and image quality throughout graded doses of dobutamine infusion administered to achieve 85% of the maximum age-predicted heart rate. Inducible ischaemia was identified if more than one segment demonstrated a new or worsening LV wall motion abnormality, and significant stenosis was defined as > or =50% luminal diameter reduction by quantitative contrast coronary angiography. Seventy-seven patients (51%) had luminal narrowings > or =50%. Diagnostic performance (sensitivity, specificity, diagnostic accuracy) of all readers was 78.2, 87.0 and 82.5%. Disagreement between two readers occurred in every seventh examination. Agreement on the presence or absence of inducible wall motion abnormalities was moderate (mean kappa value 0.59, range 0.52-0.76). Diagnostic performance and disagreement were independent of the presence of luminal narrowings > or =50% or the number of diseased coronary vessels. Image quality was regarded excellent in 89.3% of standard views. CONCLUSION: In the setting of multiple observers from different institutions performing a diagnostic reading of DSMR examinations carried out at a single centre, the interobserver variability was low for identifying inducible LV wall motion abnormalities indicative of coronary arterial luminal narrowings > or =50%.

Cardiotonic Agents↗

Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use.

PURPOSE: To prospectively evaluate breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use in coronary magnetic resonance (MR) imaging. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. In 210 consecutive patients (mean age, 61.8 years +/- 10.3 [standard deviation]; 146 men, 64 women), breath-hold patterns and maximal capability were assessed at expiration with dynamic navigator MR imaging (temporal resolution, 1 second). Left coronary artery (LCA) and right coronary artery (RCA) rest periods were determined at transverse cine imaging (steady-state free precession, retrospective gating, 40 phases per cycle). Before and after beta-blockade, rest periods were assessed in 25 additional patients (mean age, 61.4 years +/- 7.1; 20 men, five women). Differences were tested within groups with paired Student t test and between groups with unpaired Student t test (continuous variables) and chi(2) test (categoric variables). Pearson correlation was used to test the relationship between rest period and heart rate. RESULTS: Four distinct breath-hold patterns, characterized by diaphragmatic motion, were identified: pattern 1, steady plateau (55% of patients); 2, initial drift followed by plateau (12%); 3, continuous drift (19%); and 4, irregular, unsteady behavior (14%). Mean breath-hold capability with patterns 1 and 2 was 29 seconds +/- 13 (range, 10-64 seconds). The rest period of LCA was longer than that of RCA (163 msec +/- 75 vs 123 msec +/- 60; P < .01) and began earlier in the cardiac cycle (521 msec +/- 149 vs 540 msec +/- 160; P < .01); In a minority of patients, LCA rest period began later (21%) or was shorter (14%). With no pharmacologic intervention, correlation between rest period duration and heart rate was weak (LCA, r = -0.52; RCA, r = -0.38; P < .01). However, beta-blockade significantly lowered heart rate (61.3 beats/min +/- 7.2 vs 82.6 beats/min +/- 12.5, P < .001) and increased rest duration (LCA, 201.8 msec +/- 83.6 vs 111.8 msec +/- 44.55; RCA, 134.8 msec +/- 57.3 vs 83.1 msec +/- 35.8; P < .001). CONCLUSION: In 33% of patients (patterns 3 and 4), breath-hold pattern was unsuitable for high-spatial-resolution breath-hold MR imaging. LCA and RCA rest periods showed large variability in starting point and duration, with no correlation to heart rate.

Adrenergic beta-Antagonists↗

Detection of coronary stenoses with contrast enhanced, three-dimensional free breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956).

PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.

Aged↗

Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance.

AIMS: Current imaging of the coronary arteries with magnetic resonance coronary angiography (MRCA) is restricted to limited coverage of the coronary arterial tree and requires complex planning. We present and evaluate a rapid, single-scan MRCA approach with complete coverage of the coronary arterial tree. METHODS AND RESULTS: Fifty-five consecutive patients with suspected coronary artery disease underwent free-breathing, navigator-gated MRCA using a single three-dimensional volume with transversal slice orientation and nearly isotropic spatial resolution (1.2 x 1.2 x 1.4 mm(3)) with coverage of the whole heart [steady-state free precession (SSFP); TR/TE/flip angle: 5.3 ms/2.6 ms/90 degrees ; Philips Intera CV 1.5T]. The acquisition duration per heart beat was individually adapted to the cardiac rest period. Correction of respiratory motion was done using a patient-specific affine prospective navigator technique (two navigator beams: cranio-caudal position on the dome of the right hemidiaphragm and anterior-posterior position on the right chest wall; gating window 10 mm). The diagnostic performance of MRCA in detecting significant coronary stenoses was evaluated against X-ray angiography as the standard of reference (32 patients) using a 16-segment model. Effective scan duration was 18+/-6 min (navigator efficiency: 68+/-14%). In all examinations, the main epicardial vessels [left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA)], including their distal segments and major side branches (number of visible side branches: LAD, 2.0+/-0.9; LCX, 1.5+/-0.6; RCA, 2.3+/-0.9), were reliably visualized. Eighty-three per cent of all coronary segments were evaluable; sensitivity, specificity, and diagnostic accuracy were 78, 91, and 89%, respectively. CONCLUSION: The combination of an imaging sequence with an intrinsically high contrast (SSFP) and a sophisticated navigator technique (affine transformation) resulted in high quality, high resolution imaging of the whole coronary arterial tree within a short examination duration. Robustness and diagnostic accuracy may allow for a routine application in the near future.

Adult↗

Current clinical applications of stress wall motion analysis with cardiac magnetic resonance imaging.

Over the last years the indications for cardiac magnetic resonance (CMR) imaging have rapidly broadened, in particular those dealing with the non-invasive detection of myocardial ischemia. This review describes the imaging technique, methodology and safety aspects of stress cine magnetic resonance imaging and summarizes the current knowledge with regard to its applicability in clinical routine.

Adenosine↗

A new approach for rapid assessment of the cardiac rest period for coronary MRA.

BACKGROUND: Effective suppression of cardiac motion is crucial for MR coronary angiography (MRCA). Thus, we evaluated a new technique for rapid and automatic detection of the cardiac rest period in comparison to the conventional visual assessment of the coronary artery rest periods. METHODS: One hundred and thirty-five consecutive cardiac patients were examined (Philips Intera CV 1.5 T, Best, The Netherlands). Visual assessment of the left and right coronary rest periods was done using a cine-SSFP scan with a transversal slice orientation (retrospective gating, 40 phases/cardiac cycle); the coronary rest period was defined as the duration of the coronary artery being completely within a region of interest placed on the outer edge of the cross-section of the vessel. Common coronary rest period as determined from visual assessment was defined as the intersection of both coronary artery rest periods. For comparison, an automatic technique was applied: using the position of the shim volume to define a correlation kernel, the cross-correlations of consecutive cine images were registered and displayed in a graph. Based on these cross-correlation values, the cardiac rest period was detected. The correlation between the visual and automated analysis was assessed. RESULTS: A high correlation between the automatically and visually determined starting points for the coronary artery rest periods and the cardiac rest period was found. The automatically assessed cardiac rest period was significantly shorter in comparison to the visually assessed left and right coronary artery rest period (103 +/- 46 ms vs. 158 +/- 72 ms and 117 +/- 52 ms, respectively; p < 0.001). However, the common coronary rest period demonstrated excellent agreement with the cardiac rest period (r = 0.93, p < 0.001) without a significant difference in duration (109 +/- 52 ms vs. 103 +/- 46 ms). CONCLUSIONS: Automated analysis of the cardiac rest period yielded similar results compared to the visual analysis. This rapid assessment of a cardiac acquisition window may be most helpful for MRCA, especially when aiming at 3-dimensional coverage of the whole coronary arterial tree during a single scan.

Adult↗

Coronary MR angiography with steady-state free precession: individually adapted breath-hold technique versus free-breathing technique.

PURPOSE: To compare image quality and coronary artery stenosis detection with breath-hold (BH) and free-breathing navigator-gated (NAV) coronary magnetic resonance (MR) angiography performed with the same imaging sequence (steady-state free precession) and identical spatial resolution in patients suspected of having coronary artery disease. MATERIALS AND METHODS: Forty consecutive patients suspected of having coronary artery disease underwent steady-state free precession MR imaging of the left or the right coronary artery twice. Correction of breathing motion was performed once with NAV and again with BH. Maximal BH duration and coronary artery rest period were individually determined, and duration of data acquisition was adapted (parallel imaging with different sensitivity encoding factors was used). Quantitative analysis of coronary MR angiography data was performed with multiplanar reformatting software to determine visual score for image quality, vessel sharpness, visible vessel length, and number of visible side branches. Diagnostic accuracy for detection of coronary stenosis of 50% or greater was determined in comparison with results of conventional invasive angiography. The two techniques were compared regarding differences in angiographic parameters with paired Student t testing. chi(2) or Fisher exact testing was used when appropriate. RESULTS: More coronary artery segments were assessable with NAV than with BH MR angiography (254 [79.4%] vs 143 [44.7%] of 320 segments). Overall sensitivity and specificity with NAV were 72% (26 of 36 segments) and 91.7% (200 of 218 segments), versus 63% (12 of 19 segments) and 82.3% (102 of 124 segments) with BH; NAV enabled correct diagnosis in 13% more segments. BH yielded nondiagnostic images in 14 patients, while NAV yielded diagnostic images in all patients. When these 14 patients were excluded, there was a significant increase in visual score for left (3.0 vs 2.4, P <.01) and right (3.3 vs 3.0, P <.05) coronary arteries and no significant difference in vessel sharpness but significant improvement in visible vessel length in left coronary artery (85.9 vs 71.4 mm, P =.003) and number of visible side branches in left (4.9 vs 3.9, P =.04) and right (2.8 vs 2.4, P =.04) coronary arteries on NAV images as compared with BH images. CONCLUSION: Free-breathing NAV was superior to BH coronary MR angiography in terms of image quality and diagnostic accuracy of stenosis detection.

Adult↗

Comparison of radial and Cartesian imaging techniques for MR coronary angiography.

BACKGROUND: Magnetic resonance coronary angiography (MRCA) has traditionally been performed using a Cartesian k-space data acquisition scheme. Radial k-space sampling is known to be less sensitive to motion artifacts. Thus, potential improvements may be achieved with radial k-space data acquisition using steady state free precession (SSFP) techniques. We directly compared SSFP three-dimensional (3D)-MRCA using radial and Cartesian data acquisition. METHODS: Forty-four consecutive patients with suspected coronary artery disease underwent free-breathing, navigator-corrected MRCA of the left or right coronary artery using SSFP (TR/TE/flip angle: 4.5 ms/2.3 ms/90 degrees) with radial and again with Cartesian k-space filling. Quantitative MRCA was performed with a dedicated multiplanar reformatting software to determine: visual score for image quality (low=1, high=4), vessel sharpness, visible vessel length, number of visible side branches, and average vessel diameter. Diagnostic accuracy for detection of > or = 50% coronary artery stenosis was calculated in comparison to invasive X-ray angiography. RESULTS: Radial data acquisition resulted in a significant (p<0.01) increase in vessel sharpness (55.6+/-7.2% vs. 45.9+/-7.0%) but a decrease in average vessel diameter (2.6+/-0.5 mm vs. 3.0+/-0.4 mm), number of visible side branches (2.1+/-1.1 vs. 3.0+/-1.7) and number of assessable coronary artery segments (66% vs. 73%) compared to Cartesian approach. There was no significant difference regarding the diagnostic accuracy (80.8% vs. 83.9%), the visual score (2.6+/-0.9 vs. 3.0+/-0.9) and the visible vessel length (92.1+/-36.0 mm vs. 99.9+/-32.4 mm). CONCLUSIONS: MRCA with radial k-space sampling appears to be on a par with Cartesian approach with respect to the diagnostic performance in an unselected patient population. Nevertheless, with current implementations, radial sampling is inferior to Cartesian sampling regarding the visualization of side branches despite better vessel sharpness.

Adult↗

New three-dimensional echocardiographic system using digital radiofrequency data--visualization and quantitative analysis of aortic valve dynamics with high resolution: methods, feasibility, and initial clinical experience.

BACKGROUND: Common 3D systems have only limited spatial and temporal resolution (frame rate of 25 Hz). Thin structures such as cardiac valves are not imaged exactly; rapid movement patterns cannot be precisely recorded. The objective of the present project was to achieve radiofrequency (RF) data transmission to the 3D workstation to improve image resolution. METHODS AND RESULTS: A commercially available echocardiographic system (5-MHz transesophageal echocardiography probe) with an integrated raw data interface enables transmission of RF data (up to 40 megabytes per second). A 3D data set may contain up to 3 gigabytes, so that all of the high-resolution ultrasound information of the 2D image is available. Frame rates of up to 168 Hz result in temporal resolution 6 times that of standard 3D systems. The applicability of the system and the image quality were tested in 10 patients. The structure of the aortic valve and the dynamic changes were depicted by volume rendering. The changes in the orifice areas were measured in frame-by-frame planimetry. The mean number of frames recorded per cardiac cycle was 122+/-16. The improved structural resolution enabled a detailed imaging of the morphology of the aortic cusps. The rapid systolic movement patterns were recorded with up to 51 frames. The high number of frames enabled creation of precise area-time diagrams. Thus, the individual phases of aortic valve movement (rapid opening, slow valve closing, and rapid valve closing) could be analyzed quantitatively. CONCLUSIONS: A 3D system based on RF data enables high-resolution imaging of cardiac movement patterns. This offers new perspectives for qualitative and quantitative analyses, especially of cardiac valves.

Aortic Valve↗

Effects of hemodynamic instability on brain death-induced prepreservation liver damage.

BACKGROUND: Brain death (BD) is an important multifactorial variable contributing to donor-specific liver damage. Our study aimed at assessing the specific effects of hemodynamic instability on systemic and hepatic parameters of perfusion, bowel ischemia, and oxidative stress in a porcine model of BD. METHODS: BD was induced in 16 pigs (German Landrace, 18-28 kg) in two groups (hypotension-BD [HYPO-BD], n=8; normotension-BD [NORM-BD], n=8), which were compared with control animals/living donors (n=6) for a period of 2 hr. We analyzed systemic hemodynamic parameters, bowel ischemia (intramucosal pH in the stomach and colon, plasma endotoxin levels, and endotoxin-neutralizing capacity [ENC]), and oxidative stress (total glutathione levels in erythrocytes) and compared the findings with hepatic parameters of perfusion (hepatic arterial flow, portal venous flow, and microperfusion) and liver oxidative stress (reduced glutathione and oxidized glutathione levels in the liver). RESULTS: Independent of the hemodynamic stability, liver macrocirculation and microcirculation decreased (HYPO-BD, 79+/-6 to 69+/-10 mL/100 g/min; NORM-BD, 81+/-10 to 73+/-7 mL/100 g/min; P<0.05). Hepatocellular damage (aspartate aminotransferase: NORM-BD, 49+/-20 units/L; HYPO-BD, 170+/-140 units/L; P<0.01) and hepatic oxidative stress (reduced glutathione in the liver/oxidized glutathione in the liver: NORM-BD, 29.4+/-2.3 to 13.0+/-1.3; HYPO-BD, 29.4+/-2.3 to 9.05+/-0.81; P<0.001) increased in both BD groups. With dependence on systemic hemodynamic parameters, bowel ischemia increased (intramucosal pH in the colon, 7.22+/-0.01, P<0.01; ENC, 75+/-14 endotoxin-neutralizing units/mL, P<0.01; endotoxin levels, 7+/-2 to 43+/-10 pg/mL, P<0.01) in the HYPO-BD group but not in the NORM-BD group or the living donor group. Furthermore, systemic oxidative stress was increased in the HYPO-BD group only (total glutathione levels in erythrocytes, 2.65+/-0.25 to 0.15+/-0.25 mM; P<0.01). CONCLUSIONS: During BD, liver-specific parameters (portal venous flow, microperfusion, aspartate aminotransferase activity, ENC, and hepatic oxidative stress) were compromised, independent of the hemodynamic status. Therefore, the systemic hemodynamic status does not reflect the functional status of the liver during BD.

Animals↗