PubMed Health⌕ Search

Biomedical subjects

Craig H Meyer

Publications and source records attributed to Craig H Meyer.

9 recordsLinked to original sources

Can late gadolinium enhancement by cardiovascular magnetic resonance identify coronary artery disease as the etiology of new onset congestive heart failure?

BACKGROUND: New left ventricular systolic dysfunction affects 500,000 Americans and coronary artery disease (CAD) is responsible for two-thirds of cases. Identifying CAD has both prognostic and therapeutic implications. We evaluated the ability of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance imaging (CMR) to detect CAD as the etiology of recent onset congestive heart failure (CHF). METHODS: CMR and LGE were performed in 26 patients with new onset left ventricular systolic dysfunction. All patients received an x-ray angiography for identification of CAD. Patients with an acute coronary syndrome with troponin I > 1.0 ng/ml or a history of CAD were excluded. The presence and distribution of LGE was evaluated. RESULTS: Significant coronary stenoses were present in 5 of 26 patients (19%). LGE in an infarct pattern was found in 2 of the 5 patients with CAD. Of the 21 patients without CAD, 2 had midwall enhancement but none had evidence of LGE in an infarct pattern. CONCLUSIONS: When present, LGE in an infarct pattern suggests CAD as the etiology of new onset CHF. However, the absence of LGE does not exclude CAD as the underlying etiology. A small proportion of patients with a nonischemic cause of new onset CHF have LGE limited to the midwall.

Adult↗

Reproducibility and reliability of atherosclerotic plaque volume measurements in peripheral arterial disease with cardiovascular magnetic resonance.

A high resolution, noninvasive approach to quantify atherosclerotic plaque in the peripheral vasculature could have significant clinical and research utility. Seventeen patients with peripheral arterial disease (PAD) were studied in a 1.5T CMR scanner. Atherosclerotic plaque volume in the superficial femoral artery was measured and interobserver, intraobserver, and test-retest variability determined. Nineteen vessels were studied with mean acquisition time of 13.1 minutes per vessel. Mean plaque volume was 7.27 +/- 3.73 cm3. Intra-observer intraclass correlation was R = 0.997, inter-observer was R = 0.987, and test-retest reproducibility was R = 0.996. Thus, high resolution measurement of plaque volume in PAD is reliable and reproducible.

Adult↗

Delayed calf muscle phosphocreatine recovery after exercise identifies peripheral arterial disease.

OBJECTIVES: In this study we intend to characterize phosphocreatine (PCr) recovery kinetics with phosphorus-31 ((31)P) magnetic resonance spectroscopy in symptomatic peripheral arterial disease (PAD) patients compared with control subjects and determine the diagnostic value and reproducibility of this parameter. BACKGROUND: Due to the inconsistent relationship between flow and function in PAD, novel techniques focused on the end-organ are needed to assess disease severity and measure therapeutic response. METHODS: Fourteen normal subjects (5 men, age 45 +/- 14 years) and 20 patients with mild-to-moderate symptomatic PAD (12 men, age 67 +/- 10 years, mean ankle brachial index 0.62 +/- 0.13) were studied. Subjects exercised one leg to exhaustion while supine in a 1.5-T magnetic resonance scanner using a custom-built plantar flexion device. Surface coil-localized, free induction decay acquisition localized to the mid-calf was used. Each 31P spectrum consisted of 25 signal averages at a repetition time of 550 ms. The PCr recovery time constant was calculated by monoexponential fit of PCr versus time, beginning at exercise completion. RESULTS: Median exercise time was 195.0 s in normal subjects and 162.5 s in PAD patients (p = 0.06). Despite shorter exercise times in patients, the median recovery time constant of PCr was 34.7 s in normal subjects and 91.0 s in PAD patients. Area under the receiver-operating characteristic curve was 0.925 +/- 0.045. Test-retest reliability was excellent. CONCLUSIONS: The PCr recovery time constant is prolonged in patients with symptomatic PAD compared with normal subjects. The method is reproducible and may be useful in the identification of disease. Further study of this parameter's ability to track response to therapy as well as its prognostic capability is warranted.

Adult↗

Fast automatic linear off-resonance correction method for spiral imaging.

Field inhomogeneity and susceptibility variations, coupled with a long readout, can result in image blurring in spiral imaging. Many correction methods based on a priori off-resonance information, such as an acquired field map, have been proposed in the literature. Automatic off-resonance correction methods are alternative approaches that estimate a field map from the image data themselves. In this paper we propose a fast automatic off-resonance correction method that performs linear correction without acquiring a field map. The method requires only about two times the total computation time compared to image reconstruction by gridding. It can also be used in combination with a full field map automatic off-resonance correction method to increase the extent of correction. The method is demonstrated by in vivo coronary artery imaging.

Algorithms↗

Technology insight: in vivo cell tracking by use of MRI.

Animal studies have shown some success in the use of stem cells of diverse origins to treat heart failure and ventricular dysfunction secondary to ischemic injury. The clinical use of these cells is, therefore, promising. In order to develop effective cell therapies, the location, distribution and long-term viability of these cells must be evaluated in a noninvasive manner. MRI of cells labeled with magnetically visible contrast agents after either direct injection or local or intravenous infusion has the potential to fulfill this goal. In this Review, techniques for labeling and imaging a variety of cells will be discussed. Particular attention will be given to the advantages and limitations of various contrast agents and passive and facilitated cell-labeling methods, as well as to imaging techniques that produce negative and positive contrast, and the effect on image quantification of compartmentalization of contrast agents within the cell.

Animals↗

Noninvasive assessment of coronary vasodilation using magnetic resonance angiography.

OBJECTIVES: The purpose of this study was to investigate the use of coronary magnetic resonance angiography (MRA) for assessing human epicardial coronary artery vasodilation. BACKGROUND: Coronary vasodilation plays a vital role in the human coronary circulation. Previous studies of epicardial coronary vasodilation have used invasive coronary angiography. Coronary MRA may provide an alternative noninvasive method to directly assess changes in coronary size. METHODS: Thirty-two subjects were studied: 12 patients (age 55 +/- 18 years) and 20 healthy subjects (age 34 +/- 4 years). High-resolution multi-slice spiral coronary MRA (in-plane resolution of 0.52 to 0.75 mm) was performed before and after sublingual nitroglycerin (NTG). Quantitative analysis of coronary vasodilation was performed on cross-sectional images of the right coronary artery (RCA). A time-course analysis of coronary vasodilation was performed in a subset of eight subjects for 30 min after NTG. Signal-to-noise ratio was also measured on the in-plane RCA images. RESULTS: Coronary MRA demonstrated a 23% increase in cross-sectional area after NTG (16.9 +/- 7.8 mm2 to 20.8 +/- 8.9 mm2, p <0.0001), with significant vasodilation between 3 and 15 min after NTG on time-course analysis. The MRA measurements had low interobserver variability (< or =5%) and good correlation with X-ray angiography (r=0.98). The magnitude of vasodilation correlated with baseline cross-sectional area (r=0.52, p=0.03) and age (r=0.40, p=0.019). Post-NTG images also demonstrated a 31% improvement in coronary signal-to-noise ratio (p = 0.002). CONCLUSIONS: Nitroglycerin-enhanced coronary MRA can noninvasively measure coronary artery vasodilation and is a promising noninvasive technique to study coronary vasomotor function.

Adult↗

Spiral balanced steady-state free precession cardiac imaging.

Balanced steady-state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood-myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced SSFP has been combined with spiral imaging for real-time interactive cardiac MRI. New features of this method to enable scanning in a clinical setting include short, first-moment nulled spiral trajectories and interactive control over the spatial location of banding artifacts (SSFP-specific signal variations). The feasibility of spiral balanced SSFP cardiac imaging at 1.5 T is demonstrated. In observations from over 40 volunteer and patient studies, spiral balanced SSFP imaging shows significantly improved contrast compared to spiral gradient-spoiled imaging, producing better visualization of cardiac function, improved localization, and reduced flow artifacts from blood.

Artifacts↗

Spiral magnetic resonance coronary angiography with rapid real-time localization.

A spiral high-resolution coronary artery imaging sequence (SH) interfaced with real-time localization system (RT) has been developed. A clinical study of 40 patients suspected of coronary artery disease (CAD) was conducted. Segmented k-space acquisition techniques have dominated magnetic resonance coronary angiography (MRCA) over the last decade. Although a recent multicenter trial using this technique demonstrated encouraging results, the technique was hampered by low specificity. Spiral k-space acquisition had demonstrated several advantages for MRCA. Therefore, a first clinical trial implementing spiral high-resolution coronary imaging sequence with real-time localization (SH-RT) was performed.A clinical study of 40 patients suspected of CAD undergoing X-ray angiography was conducted to analyze the clinical reliability of this novel imaging system. The SH-RT had been designed to exploit the unique capability of two imaging sequences. The RT allowed a rapid localization of the coronary arteries. Then SH achieved multislice acquisition during a short breath-hold with submillimeter resolution. The MRCA data were analyzed for scan time, anatomic coverage, image quality, and accuracy in detecting CAD. In 40 subjects, SH achieved 0.7 to 0.9 mm resolution with 14-heartbeat breath-holds. Excellent or good image quality was achieved in 78% (263/337) of the coronary segments. Blinded consensus reading among three observers generated sensitivity of 76% and specificity of 91% in the detection of CAD compared with X-ray angiography. The MRCA imaging sequence implementing a novel spiral k-space acquisition technique enabled rapid and reliable imaging of the CAD in submillimeter resolution with short breath-holds.

Adult↗

Short echo time MR spectroscopic imaging of the lung parenchyma.

PURPOSE: To perform short echo time MR spectroscopic imaging of the lung parenchyma on normal volunteers. MATERIALS AND METHODS: A short echo time projection-reconstruction spectroscopic imaging sequence was implemented on a commercial 1.5T whole body MRI scanner. Images and spectra of the lung parenchyma were obtained from five normal volunteers. Breath-held spectroscopic imaging was also performed. RESULTS: Spectroscopic imaging of short-T2* species allows visualization of different anatomic structures based upon their frequency shifts. A characteristic peak from the parenchyma was seen at three ppm from water frequency. CONCLUSION: Short echo time MR spectroscopic imaging of the lung parenchyma was demonstrated in normal volunteers. This method may improve proton imaging of the lungs and add specificity to the diagnosis of pulmonary disease.

Adult↗