PubMed Health⌕ Search

Biomedical subjects

Craig J Della Valle

Publications and source records attributed to Craig J Della Valle.

At least 19 recordsLinked to original sources

Experimental and clinical performance of porous tantalum in orthopedic surgery.

Porous tantalum, a new low modulus metal with a characteristic appearance similar to cancellous bone, is currently available for use in several orthopedic applications (hip and knee arthroplasty, spine surgery, and bone graft substitute). The open-cell structure of repeating dodecahedrons is produced via carbon vapor deposition/infiltration of commercially pure tantalum onto a vitreous carbon scaffolding. This transition metal maintains several interesting biomaterial properties, including: a high volumetric porosity (70-80%), low modulus of elasticity (3MPa), and high frictional characteristics. Tantalum has excellent biocompatibility and is safe to use in vivo as evidenced by its historical and current use in pacemaker electrodes, cranioplasty plates and as radiopaque markers. The bioactivity and biocompatibility of porous tantalum stems from its ability to form a self-passivating surface oxide layer. This surface layer leads to the formation of a bone-like apatite coating in vivo and affords excellent bone and fibrous in-growth properties allowing for rapid and substantial bone and soft tissue attachment. Tantalum-chondrocyte composites have yielded successful early results in vitro and may afford an option for joint resurfacing in the future. The development of porous tantalum is in its early stages of evolution and the following represents a review of its biomaterial properties and applications in orthopedic surgery.

Animals↗

Surgical exposures in revision total knee arthroplasty.

UNLABELLED: Safely obtaining adequate exposure at the time of revision total knee arthroplasty is an integral step in successfully performing the procedure. A medial capsular approach combined with an extensive intraarticular synovectomy provides adequate exposure for most patients. If further exposure is required, a quadriceps snip can be used to free the proximal extensor mechanism. The benefits of this approach include its technically simple nature and an unaltered postoperative rehabilitation regimen. We report a series of 126 consecutive revision knee procedures in which a medial capsular approach was adequate in 111 cases, representing 92% of the patients with an intact extensor mechanism. A quadriceps snip was required in nine cases. If more extensive exposure is required for an excessively stiff or difficult to expose knee, a tibial tubercle osteotomy or V-Y quadricepsplasty provides wider exposure. LEVEL OF EVIDENCE: Therapeutic study, level IV (case series). See the Guidelines for Authors for a complete description of levels of evidence.

Arthroplasty, Replacement, Knee↗

Antibiotic susceptibility of bacteria infecting total joint arthroplasty sites.

BACKGROUND: Currently, there is no consensus regarding the principles of empiric antibiotic treatment of suspected periprosthetic infection following total knee and hip arthroplasties. This study was undertaken to attempt to establish such principles. METHODS: We performed a retrospective analysis of 146 patients who had had a total of 194 positive cultures of specimens obtained at the time of a reoperation following a total knee or total hip arthroplasty at one of two institutions. Patient demographic data, comorbid conditions, bacterial species, the antibiotic sensitivity profile, and the postoperative day on which the culture tested positive were recorded. RESULTS: Specimens from 110 hips and eighty-four knees were positive on culture. Seventy percent of the infections were classified as chronic; 17%, as acute postoperative; and 13%, as acute hematogenous. The mean time between the operation and the positive culture results was three days. Gram-positive organisms caused the majority of the infections. In the series as a whole, 88% of the bacteria were sensitive to gentamicin; 96%, to vancomycin; and 61%, to cefazolin. The most antibiotic-resistant bacterial strains were from patients for whom prior antibiotic treatment had failed. Acute postoperative infections had a greater resistance profile than did chronic or hematogenous infections. Bacteria isolated from patients with a hematogenous infection had a high sensitivity to both cefazolin and gentamicin. CONCLUSIONS: Empiric antibiotic treatment for suspected periprosthetic infection should be guided by the class of the infection and the findings of Gram staining. We believe that, until the final culture results are available, acute hematogenous infections should initially be treated by a combination of cefazolin and gentamicin therapy. All chronic and acute postoperative infections with Gram-positive bacteria and all cases in which a Gram stain fails to identify bacteria should be managed with vancomycin. Infections with Gram-negative bacteria should be managed with a third or fourth-generation cephalosporin. Infections with mixed Gram-positive and Gram-negative bacteria should be managed with a combination of vancomycin and a third or fourth-generation cephalosporin. Furthermore, we believe that if culture results and other confirmatory tests are not positive by the fourth postoperative day, termination of empiric antibiotic therapy should be considered.

Adult↗

Applications of porous tantalum in total hip arthroplasty.

Porous tantalum is an alternative metal for total joint arthroplasty components that offers several unique properties. Its high volumetric porosity (70% to 80%), low modulus of elasticity (3 MPa), and high frictional characteristics make it conducive to biologic fixation. Tantalum has excellent biocompatibility and is safe to use in vivo. The low modulus of elasticity allows for more physiologic load transfer and relative preservation of bone stock. Because of its bioactive nature and ingrowth properties, tantalum is used in primary as well as revision total hip arthroplasty components, with good to excellent early clinical results. In revision arthroplasty, standard and custom augments may serve as a structural bone graft substitute. Formation of a bone-like apatite coating in vivo affords strong fibrous ingrowth properties and allows for substantial soft-tissue attachment, indicating potential for use in cases requiring reattachment of muscles and tendons to a prosthesis. Development of modular components and femoral stems also is being evaluated. The initial clinical data and basic science studies support further investigation of porous tantalum as an alternative to traditional implant materials.

Animals↗

High failure rate of a constrained acetabular liner in revision total hip arthroplasty.

Fifty-five consecutive revision total hip arthroplasties (THAs) in 51 patients in which a constrained acetabular liner was used (Duraloc Constrained Liner, DePuy, Warsaw, Ind) were reviewed. In these revisions, 41 constrained liners were placed for recurrent instability and 14 for inadequate stability at the time of revision THA. The mean age of the cohort was 62 years, and 38 of the hips were in female patients (69%). At a minimum of 2 years, 9 of the 55 hips (16%) dislocated. Of these 9 dislocations, 8 occurred in patients who had undergone revision to a constrained liner for recurrent instability without femoral or acetabular component revision. Revision THA for recurrent instability by placing a constrained liner without optimizing other aspects of the reconstruction leads to a high rate of recurrent failure.

Acetabulum↗

Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up.

BACKGROUND: There is a renewed interest in unicompartmental knee arthroplasty. The present report describes the minimum ten-year results associated with a unicompartmental knee arthroplasty design that is in current use. METHODS: Sixty-two consecutive unicompartmental knee arthroplasties that were performed with cemented modular Miller-Galante implants in fifty-one patients were studied prospectively both clinically and radiographically. All patients had isolated unicompartmental disease without patellofemoral symptoms. No patient was lost to follow-up. Thirteen patients (thirteen knees) died after less than ten years of follow-up, leaving thirty-eight patients (forty-nine knees) with a minimum of ten years of follow-up. The average duration of follow-up was twelve years. RESULTS: The mean Hospital for Special Surgery knee score improved from 55 points preoperatively to 92 points at the time of the final follow-up. Thirty-nine knees (80%) had an excellent result, six (12%) had a good result, and four (8%) had a fair result. At the time of the final follow-up, thirty-nine knees (80%) had flexion to at least 120 degrees . Two patients (two knees) with well-fixed components underwent revision to total knee arthroplasty, at seven and eleven years, because of progression of patellofemoral arthritis. At the time of the final follow-up, no component was loose radiographically and there was no evidence of periprosthetic osteolysis. Radiographic evidence of progressive loss of joint space was observed in the opposite compartment of nine knees (18%) and in the patellofemoral space of seven knees (14%). Kaplan-Meier analysis revealed a survival rate of 98.0% +/- 2.0% at ten years and of 95.7% +/- 4.3% at thirteen years, with revision or radiographic loosening as the end point. The survival rate was 100% at thirteen years with aseptic loosening as the end point. CONCLUSIONS: After a minimum duration of follow-up of ten years, this cemented modular unicompartmental knee design was associated with excellent clinical and radiographic results. Although the ten-year survival rate was excellent, radiographic signs of progression of osteoarthritis in the other compartments continued at a slow rate. With appropriate indications and technique, this unicompartmental knee design can yield excellent results into the beginning of the second decade of use.

Aged↗

Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report.

We previously reported our results at a minimum of three and seven years after use of a porous-coated acetabular metal shell in a consecutive series of 138 revision total hip arthroplasties. The current report presents the longer-term outcomes of these procedures, at fifteen to nineteen years postoperatively. A total of twenty metal shells (14%) underwent repeat revision. Seven of the repeat revisions were performed because of recurrent dislocation, seven were done at the time of femoral revision surgery, and six were done because of infection. Nineteen of the revised shells were well fixed, and one was aseptically loose. Of the sixty-seven hips in which the acetabular component survived for more than fifteen years after the index operation, two (3%) required a change of the modular acetabular liner because of wear or osteolysis. Nine (16%) of the fifty-seven hips with at least fifteen years of radiographic follow-up had an osteolytic lesion of >1 cm in diameter. The fifteen-year survival rate of the metal shells, with failure defined as revision because of loosening or as radiographic evidence of loosening, was 97%. Revision total hip arthroplasty with this cementless acetabular component has been followed by excellent component survivorship at fifteen years; the most common reasons for repeat revision were recurrent dislocation and infection.

Acetabulum↗

Extensor mechanism allograft reconstruction after total knee arthroplasty.

BACKGROUND: Disruption of the extensor mechanism is an uncommon but catastrophic complication of total knee arthroplasty. We evaluated two techniques of reconstructing a disrupted extensor mechanism with the use of an extensor mechanism allograft in revision total knee arthroplasty. METHODS: Twenty consecutive reconstructions with the use of an extensor mechanism allograft consisting of the tibial tubercle, patellar tendon, patella, and quadriceps tendon were performed. The first seven reconstructions (Group I) were done with the allograft minimally tensioned. The thirteen subsequent procedures (Group II) were performed with the allograft tightly tensioned in full extension. All surviving allografts were evaluated clinically and radiographically after a minimum duration of follow-up of twenty-four months. RESULTS: All of the reconstructions in Group I were clinical failures, with an average postoperative extensor lag of 59 degrees (range, 40 degrees to 80 degrees ) and an average postoperative Hospital for Special Surgery knee score of 52 points. All thirteen reconstructions in Group II were clinical successes, with an average postoperative extensor lag of 4.3 degrees (range, 0 degrees to 15 degrees ) (p < 0.0001) and an average Hospital for Special Surgery score of 88 points. Postoperative flexion did not differ significantly between Group I (average, 108 degrees ) and Group II (average, 104 degrees ) (p = 0.549). CONCLUSIONS: The results of reconstruction with an extensor mechanism allograft after total knee arthroplasty depend on the initial tensioning of the allograft. Loosely tensioned allografts result in a persistent extension lag and clinical failure. Allografts that are tightly tensioned in full extension can restore active knee extension and result in clinical success. On the basis of the number of knees that we studied, there was no significant loss of flexion. Use of an extensor mechanism graft for the treatment of a failure of the extensor mechanism will be successful only if the graft is initially tensioned tightly in full extension.

Arthroplasty, Replacement, Knee↗

Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years.

One hundred twenty-three consecutive primary total hip arthroplasties in 107 patients were performed with the insertion of a cemented, all polyethylene, flanged acetabular component. At a minimum of 20 years, 66 patients had died (75 hips) and 8 patients (8 hips) were lost to follow-up evaluation, leaving 40 hips in 33 patients. At a mean of 21.1 years, 2 cups had been revised for aseptic loosening, one well-fixed cup was revised at the time of femoral component revision, and 4 additional cups had definite evidence of radiographic loosening. Survivorship analysis revealed a 77.3% survivorship for the component at 21 years, with revision or definite loosening as an endpoint (95% confidence interval, 67.8%-86.8%).

Arthroplasty, Replacement, Hip↗

Periprosthetic sepsis.

The diagnosis of septic implant failure can be difficult to make, yet is imperative for optimal patient outcomes in revision total hip arthroplasty. In most cases, a thorough history and physical examination combined with preoperative laboratory tests and an intraoperative frozen section are sufficient to differentiate septic from aseptic failure. If preoperative laboratory test values are elevated, preoperative aspiration of the hip can be used in selected patients to confirm or exclude the diagnosis of infection. Nuclear medicine studies comprise a second-line investigation to evaluate patients with a painful total hip arthroplasty in whom revision surgery otherwise is not indicated. Intraoperative tissue appearance in combination with intraoperative Gram stains are unreliable for detecting periprosthetic sepsis, and neither is adequate when considered alone for ruling out infection at the time of revision total hip arthroplasty. It is imperative that the surgeon doing revision total hip arthroplasty thoroughly understands the relative utility of preoperative and intraoperative tests used to diagnose periprosthetic sepsis.

Algorithms↗

The femur in revision total hip arthroplasty evaluation and classification.

Femoral revision total hip arthroplasty is a technically demanding procedure. In addition to these technical issues, preoperative planning can be challenging and with multiple reconstructive options available, the decision-making process can be complex. The ability to preoperatively determine the most appropriate option for reconstruction greatly assists with ensuring that the appropriate implants and instruments are available at the time of surgery. A classification of femoral bone loss is presented that guides the surgeon in selecting an appropriate method of reconstruction.

Arthroplasty, Replacement, Hip↗

Cementless acetabular reconstruction in revision total hip arthroplasty.

Reconstruction of the failed acetabular component in total hip arthroplasty (THA) can be challenging. Although there are multiple reconstructive options available, a cementless acetabular component inserted with screws has been shown to have good intermediate-term results and is the reconstructive method of choice for the majority of acetabular revisions. We reviewed the results of 138 consecutive acetabular revisions done with a hemispheric, cementless acetabular component that is sintered with Ti fiber metal mesh and was inserted with line-to-line reaming and multiple screws for fixation. At a mean of 15 years, 19 acetabular components had been revised (13.8%); seven were revised for recurrent instability, six were revised for deep periprosthetic infection, five well-fixed cups were removed at the time of femoral revision, and one cup was fixed by fibrous tissue only at the time of femoral revision and was removed. One acetabular component was radiographically loose. Survivorship of the component was 81% at 15 years when revision for any reason was considered as an end point and 96% when revision for loosening or radiographic evidence of loosening was considered as a second end point. Cementless acetabular revision provides durable results at 15 years with a low rate of failure for loosening.

Acetabulum↗

The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years.

This study reports the 11-year to 15-year results of unicompartmental knee arthroplasty with an emphasis on failure mechanisms and progression of patellofemoral arthrosis. In a prospective study of 513 consecutive potential knee replacement candidates, 59 patients (12%) had medial unicompartmental arthroplasty of the knee. All 59 patients had isolated unicompartmental disease without clinical symptoms or radiographic evidence of patellofemoral arthritis. No patient was lost to followup. The average followup was 13 years (range, 11-15 years). The mean preoperative Hospital for Special Surgery knee score of 55 points (range, 30-79 points) improved to a mean of 90 points (range, 60-100 points) at final followup. Patellofemoral symptoms were present in 1.6% of patients at 10 years; this increased markedly to 10% of patients at 15 years (p < 0.01). Four patients (10%) had moderate or severe patellofemoral symptoms at final followup; two were revised to a primary total knee replacement at 7 and 11 years for progressive patellofemoral degeneration. No component was radiographically loose and no osteolysis was seen. The Kaplan-Meier survival with loosening or revision for any reason was 98.0% +/- 2.0% at 10 years and 95.7% +/- 4.3% at 15 years. At up to 15 years, unicompartmental knee arthroplasty yielded good clinical results; however, progressive patellofemoral arthritis was the primary mode of failure.

Aged↗

Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report.

We previously reported the seven-to-ten-year results of the use of a porous-coated acetabular metal shell in a consecutive series of 204 primary total hip arthroplasties. In the present study, we evaluated the longer-term outcomes of these arthroplasties, at fifteen to eighteen years. One hundred and thirty-six (96%) of the 142 hips available for study retained the original acetabular metal shell. Three of the 142 metal shells failed secondary to aseptic loosening. Ten hips (7%) required a change of the modular acetabular liner because of excessive wear or for the treatment of osteolysis. The fifteen-year rate of survival of the metal shell, with failure defined as revision because of loosening or radiographic evidence of loosening, was 99%. The rate of survival of cementless acetabular reconstructions was excellent at fifteen years, although osteolysis and reoperations were noted to occur much more frequently as the duration of follow-up increased. The majority of the complications were related to wear of the polyethylene liner.

Acetabulum↗

Extensor mechanism allograft reconstruction after total knee arthroplasty. A comparison of two techniques.

BACKGROUND: Disruption of the extensor mechanism is an uncommon but catastrophic complication of total knee arthroplasty. We evaluated two techniques of reconstructing a disrupted extensor mechanism with use of an extensor mechanism allograft following total knee arthroplasty. METHODS: Twenty consecutive reconstructions with use of an extensor mechanism allograft consisting of the tibial tubercle, patellar tendon, patella, and quadriceps tendon were performed. The first seven reconstructions (Group I) were done with the allograft minimally tensioned. The thirteen subsequent procedures (Group II) were performed with the allograft tightly tensioned in full extension. All surviving allografts were evaluated clinically and radiographically after a minimum duration of follow-up of twenty-four months. RESULTS: All of the reconstructions in Group I were clinical failures, with an average postoperative extensor lag of 59 degrees (range, 40 degrees to 80 degrees ) and an average postoperative Hospital for Special Surgery knee score of 52 points. All thirteen reconstructions in Group II were clinical successes, with an average postoperative extensor lag of 4.3 degrees (range, 0 degrees to 15 degrees ) (p < 0.0001) and an average Hospital for Special Surgery score of 88 points. Postoperative flexion did not differ significantly between Group I (average, 108 degrees ) and Group II (average, 104 degrees ) (p = 0.549). CONCLUSIONS: The results of reconstruction with an extensor mechanism allograft after total knee arthroplasty depend on the initial tensioning of the allograft. Loosely tensioned allografts result in a persistent extension lag and clinical failure. Allografts that are tightly tensioned in full extension can restore active knee extension and result in clinical success. On the basis of the number of knees that we studied, there was no significant loss of flexion. Use of an extensor mechanism graft for the treatment of a failure of the extensor mechanism will be successful only if the graft is initially tensioned tightly in full extension. LEVEL OF EVIDENCE: Therapeutic study, Level III-2 (retrospective cohort study). See Instructions to Authors for a complete description of levels of evidence.

Aged↗

The impact of medicare reimbursement policies on simultaneous bilateral total hip and knee arthroplasty.

In October of 1992, Medicare reimbursement decreased by 50% for a second total hip or knee arthroplasty performed as part of a simultaneous bilateral procedure. The Medicare records of 67726 patients who underwent total hip and knee arthroplasty were reviewed using data from the New York State Department of Health in the period from October 1, 1989, to September 30, 1996. Simultaneous bilateral total hip arthroplasties represented 1.8% of the total number of total hip replacements performed in fiscal year 1991 (60 of 3418) compared with 1.7% (77 of 4547) performed in fiscal year 1994 (P=.902). Similarly, the number of simultaneous bilateral total knee arthroplasties did not change significantly, with simultaneous bilateral procedures representing 5.9% of the total number of total knee replacements performed in fiscal year 1991 (214 of 3620) compared with 6.2% (369 of 5,931) performed in fiscal year 1994 (P=.568).

Adult↗