Volumetric analysis of regional left ventricular function with real-time three-dimensional echocardiography: validation by magnetic resonance and clinical utility testing.

BACKGROUND: Quantitative information on regional left ventricular volumes from real-time three-dimensional echocardiographic (RT3DE) images has significant clinical potential but needs validation. AIM: To validate these measurements against cardiac magnetic resonance (CMR) and test the feasibility of automated detection of regional wall motion (RWM) abnormalities from RT3DE data. METHODS: RT3DE (Philips) and CMR (Siemens) images were obtained from 31 patients and analysed by using prototype software to semiautomatically calculate indices of regional left ventricular function, which were compared between RT3DE and CMR (linear regression, Bland-Altman). Additionally, CMR images were reviewed by an expert, whose RWM grades were used as a reference for automated classification of segments as normal or abnormal from RT3DE and from CMR images. For each modality, normal regional ejection fraction (REF) values were obtained from 15 patients with normal wall motion. In the remaining 16 patients, REFs were compared with thresholds that were derived from patients with normal wall motion and optimised using receiver operating characteristic analysis. RESULTS: RT3DE measurements resulted in good agreement with CMR. Regional indices calculated in patients with normal wall motion varied between segments, but overall were similar between modalities. In patients with abnormal wall motion, RWM was graded as abnormal in 74% segments. CMR and RT3DE thresholds were similar (16-segment average 55 (10)% and 56 (7)%, respectively). Automated interpretation resulted in good agreement with expert interpretation, similar for CMR and RT3DE (sensitivity 0.85, 0.84; specificity 0.81, 0.78; accuracy 0.84, 0.84, respectively). CONCLUSION: Analysis of RT3DE data provides accurate quantification of regional left ventricular function and allows semiautomated detection of RWM abnormalities, which is as accurate as the same algorithm applied to CMR images.

Algorithms↗

Quantification of regional left ventricular wall motion from real-time 3-dimensional echocardiography in patients with poor acoustic windows: effects of contrast enhancement tested against cardiac magnetic resonance.

OBJECTIVE: Regional left ventricular function can be assessed by real-time 3-dimensional echocardiography (RT3DE) in patients with good image quality. Our goals were to: (1) test the feasibility of RT3DE quantification of regional wall motion (RWM) in patients with poor acoustic windows who require contrast for endocardial visualization; and (2) validate these measurements against cardiac magnetic resonance (CMR) reference. METHODS: RT3DE datasets and CMR images were obtained in 24 patients. In 16 of 24 patients with suboptimal endocardial definition, RT3DE imaging was repeated with intravenous contrast and triggering at end systole and end diastole. RT3DE datasets were analyzed using custom software designed to semiautomatically detect and segment the endocardial surface and calculate RWM values. CMR images were analyzed using commercial software to obtain reference values for RWM. RESULTS: In 8 of 24 patients with good endocardial definition, RT3DE values of RWM correlated well with CMR (r = 0.73) with a small bias (-1.0 mm). In the remaining 16 patients, analysis of nonenhanced RT3DE datasets yielded lower correlation with CMR (r = 0.61) and a slightly greater bias (-1.5 mm). The agreement with CMR improved significantly (r = 0.76, bias -1.1 mm) with contrast enhancement. CONCLUSIONS: The agreement between RT3DE and CMR values of RWM is directly related to RT3DE image quality. In patients with poor acoustic windows, dual-triggered contrast enhancement improves the accuracy of RWM quantification to a level similar to that noted in patients with good images without contrast.

Computer Systems↗

Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images.

BACKGROUND: Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. METHODS AND RESULTS: RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)-time and wall motion (WM)-time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98; y=0.99x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (+/-20 mL). WM correlated highly only in basal and midventricular segments (r=0.88; y=0.85x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. CONCLUSIONS: Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

Adult↗

Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging.

Our goals were to: (1) develop a technique for 3-dimensional (3D) direct, model-independent quantitative assessment of left ventricular (LV) volume and ejection fraction based on semiautomated detection of LV endocardial surface from transthoracic near real-time full matrix-array 3D echocardiographic (FM3DE) imaging; (2) evaluate the accuracy of LV volumes obtained with this technique, using cardiac magnetic resonance imaging (MRI) measurements as the reference for comparison; and (3) determine the effects of contrast enhancement on the accuracy of FM3DE measurements. A total of 46 patients underwent 2-dimensional echocardiography, FM3DE, and cardiac MRI. End-diastolic volume, end-systolic volume, and ejection fraction were derived from endocardial borders manually traced from 2-dimensional echocardiographic images and from semiautomatically detected LV cavity from FM3DE data. In 14 patients, FM3DE was also acquired with contrast. All measurements were compared with MRI values using linear regression and Bland-Altman analyses. FM3DE was feasible in 44 of 46 patients with LV volumes < 345 mL. LV volumes and ejection fraction computed from FM3DE resulted in higher levels of agreement with MRI than conventional 2-dimensional echocardiography, with lower interobserver variability. With contrast enhancement, FM3DE significantly underestimated LV volumes and showed increased interobserver variability. Semiautomated LV endocardial surface detection from FM3DE images is feasible and results in fast and accurate assessment of LV function.

Adult↗

Dual triggering improves the accuracy of left ventricular volume measurements by contrast-enhanced real-time 3-dimensional echocardiography.

Real-time 3-dimensional echocardiographic continuous imaging (CIM) with contrast underestimates left ventricular (LV) volumes. We studied the effects of dual-triggered (DT) acquisition on the accuracy of LV volume measurements for patients with poor acoustic windows. Real-time 3-dimensional echocardiographic imaging was performed in 20 patients during LV opacification (Definity) on the same day as cardiac magnetic resonance imaging. Both CIM and DT data were analyzed using custom software to calculate end-systolic volume (ESV) and end-diastolic volume (EDV), which were compared with the cardiac magnetic resonance reference. CIM correlated well with the cardiac magnetic resonance reference (EDV: r = 0.89; ESV: r = 0.93), but underestimated EDV and ESV by 17% and 19%, respectively. In contrast, DT resulted in higher correlation (EDV: r = 0.95; ESV: r = 0.96) and smaller biases (9% and 6%, respectively). In conclusion, because the accuracy of LV volume measurements depends on the acquisition strategy of contrast-enhanced real-time 3-dimensional echocardiographic images, the use of DT instead of the conventional CIM acquisition is recommended.

Computer Systems↗

Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models.

PURPOSE: The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. METHODS: Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. RESULTS: VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and -9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). CONCLUSION: VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.

Cardiac Volume↗

Maximum likelihood segmentation of ultrasound images with Rayleigh distribution.

This study presents a geometric model and a computational algorithm for segmentation of ultrasound images. A partial differential equation (PDE)-based flow is designed in order to achieve a maximum likelihood segmentation of the target in the scene. The flow is derived as the steepest descent of an energy functional taking into account the density probability distribution of the gray levels of the image as well as smoothness constraints. To model gray level behavior of ultrasound images, the classic Rayleigh probability distribution is considered. The steady state of the flow presents a maximum likelihood segmentation of the target. A finite difference approximation of the flow is derived, and numerical experiments are provided. Results are presented on ultrasound medical images as fetal echography and echocardiography.

Algorithms↗

Left ventricular volume estimation for real-time three-dimensional echocardiography.

The application of level set techniques to echocardiographic data is presented. This method allows semiautomatic segmentation of heart chambers, which regularizes the shapes and improves edge fidelity, especially in the presence of gaps, as is common in ultrasound data. The task of the study was to reconstruct left ventricular shape and to evaluate left ventricular volume. Data were acquired with a real-time three-dimensional (3-D) echocardiographic system. The method was applied directly in the three-dimensional domain and was based on a geometric-driven scheme. The numerical scheme for solving the proposed partial differential equation is borrowed from numerical methods for conservation law. Results refer to in vitro and human in vivo acquired 3-D + time echocardiographic data. Quantitative validation was performed on in vitro balloon phantoms. Clinical application of this segmentation technique is reported for 20 patient cases providing measures of left ventricular volumes and ejection fraction.

Echocardiography, Three-Dimensional↗