PubMed Health⌕ Search

Biomedical subjects

Csaba Nemes

Publications and source records attributed to Csaba Nemes.

3 recordsLinked to original sources

[Adverse cognitive effects and ECT].

Electroconvulsive therapy (ECT) is a rapidly acting and highly effective treatment for severe and life threatening conditions seen in affective and schizophrenic diseases. Notwithstanding its therapeutic benefits, ECT remains controversial because of seizure induction, cognitive side effects, memory dysfunction and effects on cerebral physiology. These factors have raised the concern that ECT produces structural and functional brain damages. This issue continues to have a major impact on the acceptance of ECT as a therapeutic modality, both within the medical community and in public opinion. A close look at incidence, type, severity, neurofunctional and -anatomical correlates, aetiology and therapeutic approaches of the adverse cognitive effects attributed to ECT may contribute to rational and objective handling of this topic. The final chapter deals with the issue of whether ECT causes brain damage.

Amnesia, Retrograde↗

Phylogenetic diversity of avian nephritis virus in Hungarian chicken flocks.

Avian nephritis virus (ANV) infection was detected in 4-day-old to 22-day-old chickens collected on Hungarian farms between 2002 and 2005. The animals suffered from diarrhoea, growth retardation, runting-stunting syndrome, and 2 to 6% mortality was reported. Tubulonephrosis, interstitial nephritis and uricosis (gout) was diagnosed. The presence of ANV RNA was detected in chicken carcasses using reverse transcriptase-polymerase chain reaction. The virus was demonstrated in 69% of the investigated farms. The nucleotide sequence of the amplification products (corresponding to part of the genome that encodes the GP1 protein) was determined and phylogenetic analysis was performed. The nucleotide sequences showed 76 to 86% identity to the reference strain isolated in 1976 in Japan. The constructed phlyogenetic tree indicates high diversity of the Hungarian ANV sequences, regardless of their origin and year of sample collection. Analysis of the putative amino acid sequences encoded by the partial GP1 sequences also revealed high diversity of the virus. Even samples collected at the same farm, at the same time but from different flocks, differed in nucleotide and putative amino acid sequences. The possible effects of the sequence diversity on the pathogenicity, antigenicity and diagnostics of ANV are discussed.

Animals↗

Application of parallel liquid chromatography/mass spectrometry for high throughput microsomal stability screening of compound libraries.

Solution-phase and solid-phase parallel synthesis and high throughput screening have enabled biologically active and selective compounds to be identified at an unprecedented rate. The challenge has been to convert these hits into viable development candidates. To accelerate the conversion of these hits into lead development candidates, early assessment of the physicochemical and pharmacological properties of these compounds is being made. In particular, in vitro absorption, distribution, metabolism, and elimination (ADME) assays are being conducted at earlier and earlier stages of discovery with the goal of reducing the attrition rate of these potential drug candidates as they progress through development. In this report, we present an eight-channel parallel liquid chromatography/mass spectrometry (LC/MS) system in combination with custom Visual Basic and Applescript automated data processing applications for high throughput early ADME. The parallel LC/MS system was configured with one set of gradient LC pumps and an eight-channel multiple probe autosampler. The flow was split equivalently into eight streams before the multiple probe autosampler and recombined after the eight columns and just prior to the mass spectrometer ion source. The system was tested for column-to-column variation and for reproducibility over a 17 h period (approximately 500 injections per column). The variations in retention time and peak area were determined to be less than 2 and 10%, respectively, in both tests. The parallel LC/MS system described permits time-course microsomal incubations (t(o), t5, t15, t30) to be measured in triplicate and enables estimations of t 1/2 microsomal stability. The parallel LC/MS system is capable of analyzing up to 240 samples per hour and permits the complete profiling up to two microtiter plates of compounds per day (i.e., 176 test substrate compounds + sixteen controls).

Chromatography, High Pressure Liquid↗