PubMed Health⌕ Search

Biomedical subjects

Cynthia A Britton

Publications and source records attributed to Cynthia A Britton.

4 recordsLinked to original sources

Stereo CT image compositing methods for lung nodule detection and characterization.

RATIONALE AND OBJECTIVES: Stereographic display has been proposed as a possible method of improving performance in reading computed tomographic (CT) examinations acquired for lung cancer screening. Optimizing such displays is important given the large volume of image data that must be evaluated for each of these examinations. This study is designed to explore certain tradeoffs between rendering methods designed for the stereo display of CT images. MATERIALS AND METHODS: Stereo CT image compositing methods, including distance-weighted averaging, distance-weighted maximum intensity projection (MIP), and conventional MIP, were applied to lung CT images and compared for lung nodule detection and characterization. RESULTS: Using the Jonckheere test indicated a statistically significant (P < .01) increase in contrast among the three compositing methods. Wilcoxon-Mann-Whitney test showed significant differences in contrast between distance-weighted averaging and conventional MIP (P < .01) and between averaging and distance-weighted MIP (P < .05), but not between distance-weighted MIP and conventional MIP (P > .05). Conventional MIP compositing provided the highest image contrast, but produced ambiguities in local geometric detail and texture, whereas averaging resulted in the lowest contrast, but preserved geometric detail. Distance-weighted MIP partially recovered geometric information, which was lost in images composited by means of conventional MIP. CONCLUSION: Our results indicate that distance-weighted MIP may be a better choice for nodule detection in stereo lung CT images for its high local contrast and partial preservation of geometric information, whereas compositing by means of distance-weighted averaging is preferable for nodule characterization. The relative clinical value of these compositing methods needs to be evaluated further.

Algorithms↗

Hip biomechanics: importance to functional imaging.

Although well recognized the hip joint is not well understood. In many respects knowledge of the hip is similar to that of the knee several decades ago. Increased understanding of the hip's structure and function will improve our ability to diagnose and treat pre-end-stage hip joint disease. This article describes relevant anatomy and mechanics and details the crucial role that imaging plays in current assessments of hip function.

Biomechanical Phenomena↗

Prevalence effect in a laboratory environment.

PURPOSE: To measure observer performance at various levels of prevalence. MATERIALS AND METHODS: A multiobserver multiabnormality receiver operating characteristic (ROC) study to assess the effect of prevalence on observer performance was conducted. Fourteen observers, including eight faculty members, two fellows, and four residents, interpreted 1,632 posteroanterior chest images with five prevalence levels by using a nested study design. Performance comparisons were accomplished by using a multireader multicase approach to assess the effect of prevalence from 28% (69 of 249) to 2% (31 of 1,577) on diagnostic accuracy. The mean times required to review and report a case were analyzed and compared for different levels of prevalence and readers' experience. RESULTS: Area under the ROC curve demonstrated that, with the study experimental conditions, no significant effect could be measured as a function of prevalence (P >.05) for any abnormality, group of cases, or readers. There were no significant differences (P >.05) in the mean times required to review and report cases at different prevalence levels and with different groups of readers. CONCLUSION: The consistency in the results and the size of this study suggest that with laboratory conditions, if a prevalence effect exists, it is quite small in magnitude; hence, it will not likely alter conclusions derived from such studies.

Laboratories↗

Observer performance studies: detection of single versus multiple abnormalities of the chest.

OBJECTIVE: We used receiver operating characteristic (ROC) analysis to compare two methods of evaluating observer performance in detecting an abnormality on chest radiographs. In the first method, the abnormality in question, rib fracture, was one of five investigated, and it was the only one of interest in the second. MATERIALS AND METHODS: Eight experienced observers viewed 117 posteroanterior chest radiographs in two interpretation modes. Fifty-four of these images depicted rib fractures that had been rated as subtle for detection. The likelihood of the presence of a rib fracture was rated as one of five abnormalities in question in one mode and the sole abnormality of interest in the other mode. RESULTS: Six of the observers performed better during the single-abnormality mode, one performed equally well in both modes, and one performed better during the multiple-abnormality mode. The average area under the ROC curves (A(z)) was 0.73 +/- 0.07 for the multiple-abnormality mode and 0.80 +/- 0.04 for the single-abnormality mode. The results were significantly different (p < 0.05). CONCLUSION: Study methodology can significantly affect the results in ROC studies, particularly for abnormalities that may not be perceived as primary or important. The order in which abnormalities appear on a checklist report form may be important.

Area Under Curve↗