PubMed Health⌕ Search

Biomedical subjects

D A Arzouman

Publications and source records attributed to D A Arzouman.

11 recordsLinked to original sources

Endomyocardial biopsy in the heterotopic heart transplant patient.

We present a technique for rapid and easy endomyocardial biopsy of the heterotopic transplanted heart. With a recent resurgence in heterotopic heart transplantation, we believe that ours is a sound technique in obtaining both routine surveillance biopsies as well as evaluating "right-sided pressures" in the "piggy-back" heart.

Biopsy↗

Biventricular cannulation for the Thoratec ventricular assist device.

The Thoratec biventricular assist device has been used extensively as a bridge to heart transplantation. Right atrial cannulation has always been used during right ventricular support, however diminished filling and output of the right ventricular assist device have been noticed when compared with filling and output of the left ventricular assist device. We describe a technique to directly cannulate the right ventricle to maximize filling and output of the right ventricular assist device.

Cardiac Catheterization↗

Identification and voluntary reduction of vancomycin use for perioperative antibiotic prophylaxis during coronary artery bypass graft surgery.

Vancomycin prophylaxis for coronary artery bypass graft surgery without prosthetic valve implantation voluntarily decreased from 94% to 18% in one medical center. Median hospital stay (10 vs 9 days, P = .30) and number of postoperative infections (17.0% vs 14.3%, P = .60) did not differ among patients who received vancomycin and those who did not.

Adult↗

International experience with the CardioWest total artificial heart as a bridge to heart transplantation.

As the number of potential heart donors remains constant and the number of potential recipients continuous to increase, the need for circulatory devices to bridge patients becomes more important. The CardioWest total artificial heart (TAH) is a pneumatic, implantable system that totally replaces the failing ventricles. It has been utilized worldwide as a bridge to heart transplantation in 79 patients. There were 73 males and six females who received the TAH. Currently three patients remain on the device waiting for transplantation. A total of 55 patients (70%) were transplanted of which 50 survived (91% of patients transplanted) and were discharged home. Idiopathic/dilated cardiomyopathy was the most common etiology followed by ischemic cardiomyopathy. The mean duration of implant was 34 days (range 0-186 days) and the mean age of the group was 45 years (range 16-62 years). Twenty-one patients died while on the device. Multiple organ failure was the major cause of death. There were a total of 255 complications in this group that included reoperation, bleeding, hepatic failure, renal failure, respiratory failure, neurologic events, thromboembolic events, infections, device malfunction, and fit complications. This represented a mean complication rate of three events per patient. The survival rate for the CardioWest TAH of 91% of the patients who reached transplantation is an improvement over that of the Symbion registry (55% of those transplanted) probably as a result of a better patient selection and better control of the coagulation system. These results are also comparable to those survival results obtained with other biventricular and left ventricular assist devices currently available.

Adolescent↗

Heart-lung transplantation in situs inversus.

Reconstruction was accomplished in a 2 heart-lung recipients with situs inversus resulting in a left-sided systemic venous atrium. We created a large common atrium that was closed on the left side, leaving an atrial cuff on the inferior right quadrant. To this we anastomosed the donor right atrium, which had been opened laterally between the cavae. This resulted in some clockwise rotation of the ventricles and anterior positioning of the apex. The right pulmonary veins passed superior to the atrial anastomosis and posterior to the donor right atrium. Cardiopulmonary function was excellent in both cases.

Adolescent↗

Endobag.

A simple method for placing specimens in a protective bag during video-assisted thoracic surgery has been developed. The equipment is readily available, and the technique is easy to perform.

Equipment Design↗

The effect of transforming growth factor-alpha on airway angiogenesis.

A problem in lung transplantation is tracheal or bronchial dehiscence from ischemia. To determine if an angiogenic factor applied to the airway would improve capillary regrowth, a three-ring segment of trachea was completely severed and sutured in rats. In one group of animals the ischemic segment was wrapped with Gelfoam soaked in an angiogenic factor, transforming growth factor-alpha. In a second group the ischemic area was wrapped with Gelfoam soaked with only the vehicle. In a third group the devascularized area received no additional treatment. One animal from each group was killed daily for 7 days after operation. The tracheal vasculature was cast and viewed by light and scanning electron microscopy. None of the four animals that died early were in the transforming growth factor-alpha group. All animals lost weight between the day of operation and death, but this was least in the transforming growth factor-alpha group (p = 0.05). The light microscopy showed ischemic changes and the development of granulation tissue. The scanning electron microscopy of the vascular casts showed extensive loss of the vessels in the cut area. On day 1 the vessels of all animals dilated and their walls became rough. By day 3 a few corkscrew vessels penetrated the ischemic zone. By day 4 the animal that received transforming growth factor-alpha had more capillaries than the others. By day 6 revascularization in the transforming growth factor-alpha animal was abundant. Besides budding, new capillaries appeared to develop by lateral growth. After the fifth day vessels about 30 to 50 microns in diameter bulged focally. On the bulges, ridges the size, shape, and pattern of capillaries formed. Capillary formation in this manner has not been reported previously. Revascularization emerged sooner and more extensively with transforming growth factor-alpha. No adverse effect of transforming growth factor-alpha was found.

Animals↗

Splenic septic emboli in endocarditis.

The significance of septic emboli to the spleen is inferred by the frequency of septic emboli in general seen in patients with left-sided infective endocarditis who are referred for valve replacement. To determine the proper management of splenic infarcts and abscess due to septic emboli, we retrospectively reviewed the records of 108 patients with left-sided endocarditis who underwent valvular surgery at the University of Illinois Hospital from 1980 through 1988. Intravenous drug abuse was the etiology in 68% (n = 73). The incidence of splenic infarcts and abscess was 19% (n = 20), but an incidental finding of splenic infarcts was found in 38% (n = 11) of 29 asymptomatic patients who had computed tomograms. Streptococci and staphylococci were the causative organisms in 85% (n = 17). Localized findings were absent in 90% of splenic infarcts and abscesses. Abdominal computed tomograms were diagnostic of the sequelae of splenic septic emboli in 100%. No patient had intra-abdominal bleeding complications associated with cardiopulmonary bypass. Splenectomy was performed in 50% (n = 10) of patients 3-24 days (mean, 11.2 days) after valve replacement. Indications for splenectomy included persistent sepsis in 60% (n = 6), large (greater than 2 cm) and peripheral lesions in 30% (n = 3), and splenic rupture in 10% (n = 1). Perioperative mortality of patients who underwent splenectomy was 30% (n = 3). The following conclusions can be drawn: 1) Splenic septic embolus is common in endocarditis. 2) Abdominal computed tomography should be performed for all patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Abscess↗

Success rates of long-term circulatory assist devices used currently for bridge to heart transplantation.

Circulatory assist devices as bridge to heart transplantation have become more important as the number of possible recipients has increased and the number of donors remains stable. The number of patients successfully bridged and discharged home after transplantation was determined for the Novacor Left Ventricular Assist System (Baxter Healthcare Corp., Oakland, CA) (LVAS), console and wearable; the TCI Left Ventricular Assist Device (Thermo Cardio Systems Inc., Woburn, MA) (LVAD), pneumatic and electric; the Thoratec LVAD and Biventricular Assist Device (Thoratec Lab Co., Berkeley, CA) (BIVAD); and the CardioWest total artificial heart (CardioWest Tech. Inc., Tuscon, AZ) (TAH). A total of 1,286 devices (14% Novacor console, 14% Novacor wearable, 35% TCI pneumatic, 4% TCI electric, 10% thoratec LVAD, 19% Thoratec BIVAD, and 4% CardioWest TAH) were implanted worldwide since 1984. A total of 776 (60%) patients reached heart transplantation and 687 patients (88.5% of those transplanted) were discharged home. The individual success rate for each device to bridge a patient to heart transplantation and be discharged home is as follows: Novacor LVAS console, 90%; Novacor LVAS wearable, 92%; TCI LVAD pneumatic, 89%; TCI LVAD electric, 89%; Thoratec LVAD, 93%; Thoratec BIVAD, 81%; and CardioWest TAH, 92%. The success rate with all the available systems to bridge a patient to heart transplantation and be discharged home is similar for all devices. The criteria used to determine which system to be used should be individualized for each patient. Some of the factors that should be considered in making a decision on which device to use should include anticoagulation, univentricular vs biventricular failure, mobility, protocol to discharge home, and size of the patient.

Adult↗

Cost analysis of the Novacor Left Ventricular Assist System as an outpatient bridge to heart transplantation.

Three patients were bridged to heart transplantation with the wearable Novacor Left Ventricular Assist System (Baxter Healthcare Corp., Oakland, CA) (LVAS). Two have been transplanted and discharged. The third patient remains at home. Hospitalization costs, which include the unit room charge, admission profile to the unit, and daily supply charge, were determined for all patients and compared. The patients were transferred from the surgical intensive care unit to a telemetry unit once they were hemodynamically stable. The projected hospitalization costs, if the patients had remained in the hospital, were calculated to determine probable savings for the third party payer. The average period from admission to placement of the Novacor LVAS was 15 days (range, 7-21 days). The average hospitalization cost from admission to time of Novacor left ventricular assist device implant was $2,240/day, and the average hospitalization cost after implant to discharge was $1,570/day. Hospitalization cost savings were $2,632 for the first patient, $5,922 for the second patient, and $132,124 for the third patient, who has not been transplanted. Although the number of patients is small, the daily hospitalization cost was higher before the Novacor LVAS was implanted. This is related to the severity of the disease and the length of stay in a surgical intensive care unit. There also is a significant cost savings for the third party payer, especially if the patient has to wait a significant amount of time before heart transplantation. These are important considerations in this time of managed care.

Ambulatory Care↗

Metastatic mucinous adenocarcinoma of the heart.

A case of metastatic mucinous adenocarcinoma to the heart is described. The patient presented with neurological symptoms consistent with an embolic cerebrovascular accident. Evaluation by the referring cardiologist at that time showed what appeared to be a left atrial myxoma. In a review of the English language medical literature, no other case of this nature was found.

Adenocarcinoma, Mucinous↗