Microchip isoelectric focusing using a miniature scanning detection system.

A miniature scanning fluorescent detector has been developed for plastic microchannel isoelectric focusing (mIEF) analysis. The detector, comprised of a lamp and photomultiplier tube (PMT) on a moving stage, measured the real-time distribution of fluorescently labeled peptides subjected to gel-free mIEF. During the run, the effective length of the 6-cm channel was scanned every 9 s. Analysis was completed within 5 min while still obtaining high resolution and sensitivity. In addition, the scanning detector was used to characterize peptide migration properties within the channel by providing simultaneous temporal and spatial measurements.

Amino Acid Sequence↗

A microfluidic cartridge to prepare spores for PCR analysis.

A prototype cartridge system is described that rapidly disrupts Bacillus spores by sonication, adds PCR reagent to the disrupted spores, and dispenses the mixture into a PCR tube. The total time to automatically process the spores in the cartridge and then detect the spore DNA by real-time PCR was 20 min.

Bacillus↗

Description and demonstration of a CMOS amplifier-based-system with measurement and stimulation capability for bioelectrical signal transduction.

An extracellular recording system incorporating an electrode array and an amplifier/stimulator CMOS chip is described and characterized. Important features of this custom VLSI chip include 16 instrumentation amplifiers with a gain of 50 and the incorporation of a cross-point array allowing designation of an extracellular microelectrode as either a stimulator or sensor. The planar array consisted of 32 microelectrodes, 14 microns in diameter, and four larger reference electrodes. Microelectrodes, interconnecting traces, and bond pads were patterned with a 500-nm layer of gold. The interconnecting traces were passivated with a 1-micron thick layer of silicon nitride to provide chemical and electrical insulation and microelectrode impedance was lowered utilizing electrode position of platinum black. The amplifier exhibited a nearly flat frequency response with high pass and low pass corner frequencies of 0.7 Hz and 50 kHz, respectively. The input referred noise over the 50 kHz bandwidth was 12-16 microVRMS, well below the magnitude of previously reported extracellular potentials. Crosstalk between neighboring channels resulted in an output signal below the amplifier noise level, even for relatively large extracellular potentials. Using this system, extracellular recording were demonstrated yielding typical peak-to-peak biopotentials of magnitude 0.9-2.1 mV and 100-400 microV for chick cardiac myocytes and rat spinal cord neurons, respectively. The key components of this extracellular recording system can be manufactured using industry standard thin film photolithographic techniques.

Amplifiers, Electronic↗

Microelectrode arrays for stimulation of neural slice preparations.

A planar 6 x 6 array of iridium electrodes with four reference electrodes has been developed for use with neural tissue preparations. Precise knowledge of the relative locations of the array elements allows for spatial neurophysiological analyses. The 10 microns diameter platinized iridium electrodes on a 100 microns pitch have been used to stimulate acutely prepared slices of spinal cord from free-ranging rodents. An intracellular recording from a single neuron in the substantia gelatinosa (SG) using the whole-cell, tight-seal technique allowed low noise, high resolution studies of excitatory or inhibitory electrical responses of a given neuron to inputs from the primary afferent fibers or from stimulation by individual electrodes of the array. The resulting maps of responses provide an indication of the interconnectivity of neural processes. The pattern emerging is that of limited interconnectivity in the SG from areas surrounding a recorded neuron but with strong excitatory or inhibitory effects from those oriented in a longitudinal (rostral-caudal) direction relative to the neuron. The observations to date suggest the neurons of the SG are arranged in sets of independent networks, possibly related to sensory modality and input from particular body regions.

Animals↗

Development and application of cell-based biosensors.

Biosensors incorporate a biological sensing element that converts a change in an immediate environment to signals conducive for processing. Biosensors have been implemented for a number of applications ranging from environmental pollutant detection to defense monitoring. Biosensors have two intriguing characteristics: (1) they have a naturally evolved selectivity to biological or biologically active analytes; and (2) biosensors have the capacity to respond to analytes in a physiologically relevant manner. In this paper, molecular biosensors, based on antibodies, enzymes, ion channels, or nucleic acids, are briefly reviewed. Moreover, cell-based biosensors are reviewed and discussed. Cell-based biosensors have been implemented using microorganisms, particularly for environmental monitoring of pollutants. Biosensors incorporating mammalian cells have a distinct advantage of responding in a manner that can offer insight into the physiological effect of an analyte. Several approaches for transduction of cellular signals are discussed: these approaches include measures of cell metabolism, impedance, intracellular potentials, and extracellular potentials. Among these approaches, networks of excitable cells cultured on microelectrode arrays are uniquely poised to provide rapid, functional classification of an analyte and ultimately constitute a potentially effective cell-based biosensor technology. Three challenges that constitute barriers to increased cell-based biosensor applications are presented: analytical methods, reproducibility, and cell sources. Possible future solutions to these challenges are discussed.

Antibodies↗