Contact lens standards.

The British Standards Institution (BSI) is in the process of publishing an extensive series of standards relating to contact lenses which were originally formulated as International and European Standards. Standards specifying tolerance limits for the manufacture of rigid and hydrogel lenses have been based upon data on reproducibility derived from 'ring tests' in which measurements are made by a series of independent operators. Despite publication of an International Standard on terminology in 1986, some authors persist in using obsolete terms and this practice is deplored.

Journal Article↗

Bone conduction implants for amplification: comparison of results.

We compared the results from the North American patient database on the Xomed Audiant Bone Conductor to those reported on the NobleBiocare (previously Noblepharma) HC200 bone-anchored hearing aid (BAHA) implant, using the literature and specific results provided by one of the authors. It has been proposed that the percutaneous coupling of the NobleBiocare implant transduces energy more powerfully than the Audiant transcutaneous coupling. If true, percutaneous coupling could provide greater amplification, helping patients experiencing both conductive and sensorineural hearing loss. Aided sound-field thresholds corresponding to bone-conduction thresholds were compared retrospectively through the speech frequencies. Both the BAHA and the Audiant devices amplified in the sound field to approximate preoperative bone-conduction thresholds. No statistically significant differences existed between the amplification of warble tones through the speech frequencies for either device. We conclude that amplification with the Audiant device offers as much gain as the HC200 device through the speech frequencies. While both devices can supply effective amplification for select patients suffering from conductive hearing loss, neither provides gain superior to preoperative bone-conduction thresholds to address the needs of select patients with a substantial sensorineural component.

Adult↗

Long-term results for the Xomed Audiant Bone Conductor.

The Audiant Bone Conductor is now used worldwide. Results consistently demonstrate that when used on patients within the recommended criteria, hearing thresholds are improved to within 10 dB of the preoperative bone conduction threshold. In this article, comparisons are made with the reported results of the Audiant versus other comparable bone conduction devices, or with surgical procedures for conditions such as congenital aural atresia.

Auditory Threshold↗