Publications and source records attributed to D A Jaffray.

At least 19 recordsLinked to original sources

Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer.

PURPOSE: Advances in technology allow the creation of complex treatment plans with tightly conforming doses. However, variations in positioning of the organ/patient with respect to treatment beams necessitate the use of an appreciable margin, potentially limiting dose escalation in many patients. To (1) reduce this margin and (2) test the hypothesis that the achievable level of dose escalation is patient dependent, a patient-specific, confidence-limited planning target volume (cl-PTV) was constructed using an adaptive radiotherapy (ART) process for prostate cancer treatment developed in-house. The potential dose escalation achievable with this ART process is quantified for both conformal radiotherapy (CRT) delivery and intensity-modulated radiotherapy (IMRT) delivery. MATERIAL AND METHODS: Patients with organ confined prostate cancer were entered prospectively into an ART process developed in-house. This ART process has been designed to improve accuracy and precision of dose delivery, consequently enhancing dose escalation. In this process, a cl-PTV is constructed for each patient in the second week of treatment based upon on-line portal and CT images acquired during the first week of treatment. The treatment prescription dose, defined as the minimum dose to the cl-PTV, is selected based on predefined dose-volume constraints for rectum/bladder and derived from the pretreatment planning CT image. In addition, the treatment modality (CRT or IMRT) is determined based on the level of dose escalation achievable and the risk of inaccurate targeting. The potential for both dose escalation and the application of IMRT was evaluated by comparing the prescription doses delivered using the ART process, with the cl-PTV, to those in the traditional treatment process, with a conventional generic PTV. In addition, the distributions of potential geometric target underdosing and normal tissue overdosing were also calculated to evaluate the quality of the conventional treatment plans. RESULTS: One hundred and fifty patients have been treated with the ART process. When compared to the treatment dose delivered with the conventional treatment process (generic PTV), an average 5% (2.5--10%) more dose could be delivered using the ART process with CRT, and 7.5% (2.5--15%) more dose could be delivered with IMRT. Of the 150 patients, 70% were treated to a minimum cl-PTV dose > or = 77.4 Gy (81.3 Gy ICRU isocenter dose). Dosimetric analysis revealed that 81 Gy to the cl-PTV (or 86.7 Gy ICRU) could be prescribed to at least 50% of patients if IMRT was applied using the ART process. In contrast, IMRT did not yield an obvious dose escalation gain if patients were treated using the generic PTV. Our results also demonstrate that the cl-PTV is significantly smaller than the conventional generic PTV for most patients, with a mean volume reduction of 24% (range, 5--43%). CONCLUSION: These results support our hypothesis that the achievable level of dose escalation using ART is patient dependent. By using the ART process to develop a cl-PTV, one can (1) optimize the dose level, (2) increase the applicability of IMRT, and (3) improve the quality of dose delivery. The ART process provides the foundation to identify a suitable option (CRT or IMRT) for the delivery of a safe treatment and dose escalation. It is now our standard of practice for prostate cancer treatment.

Adenocarcinoma↗

Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

A system for cone-beam computed tomography (CBCT) based on a flat-panel imager (FPI) is used to examine the magnitude and effects of x-ray scatter in FPI-CBCT volume reconstructions. The system is being developed for application in image-guided therapies and has previously demonstrated spatial resolution and soft-tissue visibility comparable or superior to a conventional CT scanner under conditions of low x-ray scatter. For larger objects consistent with imaging of human anatomy (e.g., the pelvis) and for increased cone angle (i.e., larger volumetric reconstructions), however, the effects of x-ray scatter become significant. The magnitude of x-ray scatter with which the FPI-CBCT system must contend is quantified in terms of the scatter-to-primary energy fluence ratio (SPR) and scatter intensity profiles in the detector plane, each measured as a function of object size and cone angle. For large objects and cone angles (e.g., a pelvis imaged with a cone angle of 6 degrees), SPR in excess of 100% is observed. Associated with such levels of x-ray scatter are cup and streak artifacts as well as reduced accuracy in reconstruction values, quantified herein across a range of SPR consistent with the clinical setting. The effect of x-ray scatter on the contrast, noise, and contrast-to-noise ratio (CNR) in FPI-CBCT reconstructions was measured as a function of SPR and compared to predictions of a simple analytical model. The results quantify the degree to which elevated SPR degrades the CNR. For example, FPI-CBCT images of a breast-equivalent insert in water were degraded in CNR by nearly a factor of 2 for SPR ranging from approximately 2% to 120%. The analytical model for CNR provides a quantitative understanding of the relationship between CNR, dose, and spatial resolution and allows knowledgeable selection of the acquisition and reconstruction parameters that, for a given SPR, are required to restore the CNR to values achieved under conditions of low x-ray scatter. For example, for SPR = 100%, the CNR in FPI-CBCT images can be fully restored by: (1) increasing the dose by a factor of 4 (at full spatial resolution); (2) increasing dose and slice thickness by a factor of 2; or (3) increasing slice thickness by a factor of 4 (with no increase in dose). Other reconstruction parameters, such as transaxial resolution length and reconstruction filter, can be similarly adjusted to achieve CNR equal to that obtained in the scatter-free case.

Biophysical Phenomena↗

Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.

AAPM Task Group 58 was created to provide materials to help the medical physicist and colleagues succeed in the clinical implementation of electronic portal imaging devices (EPIDs) in radiation oncology. This complex technology has matured over the past decade and is capable of being integrated into routine practice. However, the difficulties encountered during the specification, installation, and implementation process can be overwhelming. TG58 was charged with providing sufficient information to allow the users to overcome these difficulties and put EPIDs into routine clinical practice. In answering the charge, this report provides; comprehensive information about the physics and technology of currently available EPID systems; a detailed discussion of the steps required for successful clinical implementation, based on accumulated experience; a review of software tools available and clinical use protocols to enhance EPID utilization; and specific quality assurance requirements for initial and continuing clinical use of the systems. Specific recommendations are summarized to assist the reader with successful implementation and continuing use of an EPID.

Biophysical Phenomena↗

High resolution gel-dosimetry by optical-CT and MR scanning.

The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that gel-dosimetry in conjunction with optical-CT scanning can yield maps of dose that are of sufficient accuracy, resolution and precision to allow verification of complex radiosurgery deliveries, and by extension IMRT deliveries. The radiosurgery dose-distribution represents the most challenging case encountered in external beam therapy by virtue of the steep dose-gradients and high resolution of delivery. We characterize the stringent radiosurgery requirements by the RTAP (Resolution-Time-Accuracy-Precision) criteria defined as < or = 1 mm3 spatial resolution, < or = 1 hour imaging time, accurate to within 3%, and within -1% precision. The RTAP criteria is applied to an in-house laser-based optical-CT scanning system presented here, and evaluated using gel-flasks containing BANG3 gel. The same gel flasks were subsequently imaged using the MR imaging protocol recommended by the gel manufacturer, but modified to match as closely as possible the RTAP. The resulting dose-maps demonstrate the high precision (< 1.3% noise at high dose) achievable with optical CT scanning while preserving high spatial resolution (<1 mm3). Using the sequence above, the MR gel-dose maps were found to have poorer precision by a factor of 5, under the strict conditions of the RTAP. The optical CT gel-dosimetry system was further evaluated for the verification of a complex 3-isocenter radiosurgery delivery. In conclusion, this work demonstrates that gel-dosimetry and optical-CT scanning approach an important long-term goal of radiation dosimetry, as specified by the RTAP criteria, and have potential to impact the clinic by improving and facilitating clinical dose verification for the most complex external beam radiation treatments.

Calibration↗

Active breathing control (ABC) for Hodgkin's disease: reduction in normal tissue irradiation with deep inspiration and implications for treatment.

PURPOSE: Active breathing control (ABC) temporarily immobilizes breathing. This may allow a reduction in treatment margins. This planning study assesses normal tissue irradiation and reproducibility using ABC for Hodgkin's disease. METHODS AND MATERIALS: Five patients underwent CT scans using ABC obtained at the end of normal inspiration (NI), normal expiration (NE), and deep inspiration (DI). DI scans were repeated within the same session and 1-2 weeks later. To simulate mantle radiotherapy, a CTV1 was contoured encompassing the supraclavicular region, mediastinum, hila, and part of the heart. CTV2 was the same as CTV1 but included the whole heart. CTV3 encompassed the spleen and para-aortic lymph nodes. The planning target volume (PTV) was defined as CTV + 9 mm. PTVs were determined at NI, NE, and DI. A composite PTV (comp-PTV) based on the range of NI and NE PTVs was determined to represent the margin necessary for free breathing. Lung dose-mass histograms (DMH) for PTV1 and PTV2 and cardiac dose-volume histograms (DVH) for PTV3 were compared at the three different respiratory phases. RESULTS: ABC was well-tolerated by all patients. DI breath-holds ranged from 34 to 45 s. DMHs determined for PTV1 revealed a median reduction in lung mass irradiated at DI of 12% (range, 9-24%; n = 5) compared with simulated free-breathing. PTV2 comparisons also showed a median reduction of 12% lung mass irradiated (range, 8-28%; n = 5). PTV3 analyses revealed the mean volume of heart irradiated decreased from 26% to 5% with deep inspiration (n = 5). Lung volume comparisons between intrasession and intersession DI studies revealed mean variations of 4%. CONCLUSION: ABC is well tolerated and reproducible. Radiotherapy delivered at deep inspiration with ABC may decrease normal tissue irradiation in Hodgkin's disease patients.

Heart↗

Improving the dosimetric coverage of interstitial high-dose-rate breast implants.

PURPOSE/OBJECTIVE: We performed a retrospective computed tomography (CT)-based three-dimensional (3D) dose-volume analysis of high-dose-rate (HDR) interstitial breast implants to evaluate the adequacy of lumpectomy cavity coverage, and then designed a simple, reproducible algorithm for dwell-time adjustment to correct for underdosage of the lumpectomy cavity. METHODS AND MATERIALS: Since March 1993, brachytherapy has been used as the sole radiation modality after lumpectomy in selected protocol patients with early-stage breast cancer treated with breast-conserving therapy. In this protocol, all patients received 32 Gy in 8 fractions of 4 Gy over 4 days. Eleven patients treated with HDR brachytherapy who underwent CT scanning after implant placement were included in this analysis. For each patient, the postimplant CT dataset was transferred to a 3D treatment planning system, and the relevant tissue volumes were outlined on each axial slice. The implant dataset, including the dwell positions and dwell times, were imported into the 3D planning system and then registered to the visible implant template in the CT dataset. The calculated dose distribution was analyzed with respect to defined volumes via dose-volume histograms. Due to the variability of lumpectomy cavity coverage discovered in this 3D quality assurance analysis, dwell times at selected positions were adjusted in an attempt to improve dosimetric coverage of the lumpectomy cavity. Using implant data from 5 cases, a dwell-time adjustment algorithm was designed and was then tested on 11 cases. In this algorithm, a point P was identified using axial CT images, which was representative of the underdosed region within the cavity. The distance (d) from point P to the nearest dwell position was measured. A number of dwell positions (N) nearest to point P were selected for dwell time adjustment. The algorithm was tested by increasing the dwell times of a variable number of positions (N = 1, 3, 5, 7, 10, and 20) by a weighting factor (alpha), where alpha = f(d) and alpha > 1, and subsequently performing 3D dose-volume analysis to evaluate the improvement in lumpectomy cavity coverage. RESULTS: Before adjustment in the 11 implants, the median proportion of the lumpectomy cavity and target volume that received at least the prescription dose was 85% and 68%, respectively. After dwell-time adjustment, lumpectomy cavity coverage was significantly improved in all 11 cases. The median distance from point P to the nearest dwell position (d) was 1.4 cm (range 0.9-1.9). The median volume of the lumpectomy cavity receiving 32 Gy increased from 85.3% in the actual implant to 97.0% (range 74-100%) by increasing the dwell time of a single dwell position by a median factor (alpha) of 12.2 according to the above algorithm. With N = 3, the median proportion of the cavity volume receiving 32 Gy was improved to 97.5% (range 77-100%), with a median alpha of 5.7. Further improvement in lumpectomy cavity coverage was relatively small by increasing additional dwell times. In addition, with N = 20, the median absolute volume of breast tissue receiving 150% of the prescription dose was 70.3 cm3 compared to 26.3 cm3 in the actual implant; whereas with N = 1 or N = 3, this median volume was only 35.9 and 42.0 cm3, respectively. CONCLUSION: Lumpectomy cavity coverage sometimes appears suboptimal with interstitial HDR breast brachytherapy using our current technique. A simple dwell-time increase at only 1-3 dwell positions can compensate for some underdosage without creating significant regions of overdosage. Using simple methodology, a single reference point representing the underdosed region can be utilized for initial selection of the dwell positions to be increased.

Algorithms↗

Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal system configuration. Cascaded systems analysis of flat-panel imagers (FPIs) is extended to incorporate the effects of x-ray scatter directly in the DQE, showing that x-ray scatter degrades DQE as an additive noise source. Optimal magnification is computed for FPI configurations appropriate to (but not limited to) cone-beam computed tomography (CBCT). The sensitivity of the results is examined as a function of focal spot size, imaging task (e.g., ideal observer detection or discrimination tasks), x-ray scatter fraction, detector resolution, and additive noise. Nominal conditions for FPI-CBCT result in optimal magnification of approximately 1.4-1.6, depending primarily on the magnitude of the x-ray scatter fraction. The methodology is sufficiently general that examination of optimal geometry for other FPI applications (e.g., chest radiography, fluoroscopy, and mammography) is possible. The degree to which increased exposure can be used to compensate for x-ray scatter degradation is quantified.

Algorithms↗

Characterization of a fluoroscopic imaging system for kV and MV radiography.

An on-line kilovoltage (kV) imaging system has been implemented on a medical linear accelerator to verify radiotherapy field placement. A kV x-ray tube is mounted on the accelerator at 90 degrees to the megavoltage (MV) source and shares the same isocenter. Nearly identical CCD-based fluoroscopic imagers are mounted opposite the two x-ray sources. These systems are being used in a clinical study of patient setup error that examines the advantage of kV imaging for on-line localization. In the investigation reported here, the imaging performance of the kV and MV systems are characterized to provide support to the conclusions of the studies of setup error. A spatial-frequency-dependent linear systems model is used to predict the detective quantum efficiencies (DQEs) of the two systems. Each is divided into a series of gain and spreading stages. The parameters of each stage are either measured or obtained from the literature. The model predicts the system gain to within 7% of the measured gain for the MV system and to within 10% for the kV system. The systems' noise power spectra (NPSs) and modulation transfer functions (MTFs) are measured to construct the measured DQEs. X-ray fluences are calculated using modeled polyenergetic spectra. Measured DQEs agree well with those predicted by the model. The model reveals that the MV system is well optimized, and is x-ray quantum noise limited at low spatial frequencies. The kV system is suboptimal, but for purposes of patient positioning yields images superior to those produced by the MV system. This is attributed to the kV system's higher DQE and to the inherently higher contrasts present at kV energies.

Biophysical Phenomena↗

Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

The development and performance of a system for x-ray cone-beam computed tomography (CBCT) using an indirect-detection flat-panel imager (FPI) is presented. Developed as a bench-top prototype for initial investigation of FPI-based CBCT for bone and soft-tissue localization in radiotherapy, the system provides fully three-dimensional volumetric image data from projections acquired during a single rotation. The system employs a 512 x 512 active matrix of a-Si:H thin-film transistors and photodiodes in combination with a luminescent phosphor. Tomographic imaging performance is quantified in terms of response uniformity, response linearity, voxel noise, noise-power spectrum (NPS), and modulation transfer function (MTF), each in comparison to the performance measured on a conventional CT scanner. For the geometry employed and the objects considered, response is uniform to within 2% and linear within 1%. Voxel noise, at a level of approximately 20 HU, is comparable to the conventional CT scanner. NPS and MTF results highlight the frequency-dependent transfer characteristics, confirming that the CBCT system can provide high spatial resolution and does not suffer greatly from additive noise levels. For larger objects and/or low exposures, additive noise levels must be reduced to maintain high performance. Imaging studies of a low-contrast phantom and a small animal (a euthanized rat) qualitatively demonstrate excellent soft-tissue visibility and high spatial resolution. Image quality appears comparable or superior to that of the conventional scanner. These quantitative and qualitative results clearly demonstrate the potential of CBCT systems based upon flat-panel imagers. Advances in FPI technology (e.g., improved x-ray converters and enhanced electronics) are anticipated to allow high-performance FPI-based CBCT for medical imaging. General and specific requirements of kilovoltage CBCT systems are discussed, and the applicability of FPI-based CBCT systems to tomographic localization and image-guidance for radiotherapy is considered.

Animals↗

A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets.

PURPOSE: Dose escalation in conformal radiation therapy requires accurate field placement. Electronic portal imaging devices are used to verify field placement but are limited by the low subject contrast of bony anatomy at megavoltage (MV) energies, the large imaging dose, and the small size of the radiation fields. In this article, we describe the in-house modification of a medical linear accelerator to provide radiographic and tomographic localization of bone and soft-tissue targets in the reference frame of the accelerator. This system separates the verification of beam delivery (machine settings, field shaping) from patient and target localization. MATERIALS AND METHODS: A kilovoltage (kV) x-ray source is mounted on the drum assembly of an Elekta SL-20 medical linear accelerator, maintaining the same isocenter as the treatment beam with the central axis at 90 degrees to the treatment beam axis. The x-ray tube is powered by a high-frequency generator and can be retracted to the drum-face. Two CCD-based fluoroscopic imaging systems are mounted on the accelerator to collect MV and kV radiographic images. The system is also capable of cone-beam tomographic imaging at both MV and kV energies. The gain stages of the two imaging systems have been modeled to assess imaging performance. The contrast-resolution of the kV and MV systems was measured using a contrast-detail (C-D) phantom. The dosimetric advantage of using the kV imaging system over the MV system for the detection of bone-like objects is quantified for a specific imaging geometry using a C-D phantom. Accurate guidance of the treatment beam requires registration of the imaging and treatment coordinate systems. The mechanical characteristics of the treatment and imaging gantries are examined to determine a localizing precision assuming an unambiguous object. MV and kV radiographs of patients receiving radiation therapy are acquired to demonstrate the radiographic performance of the system. The tomographic performance is demonstrated on phantoms using both the MV and the kV imaging system, and the visibility of soft-tissue targets is assessed. RESULTS AND DISCUSSION: Characterization of the gains in the two systems demonstrates that the MV system is x-ray quantum noise-limited at very low spatial frequencies; this is not the case for the kV system. The estimates of gain used in the model are validated by measurements of the total gain in each system. Contrast-detail measurements demonstrate that the MV system is capable of detecting subject contrasts of less than 0.1% (at 6 and 18 MV). A comparison of the kV and MV contrast-detail performance indicates that equivalent bony object detection can be achieved with the kV system at significantly lower doses (factors of 40 and 90 lower than for 6 and 18 MV, respectively). The tomographic performance of the system is promising; soft-tissue visibility is demonstrated at relatively low imaging doses (3 cGy) using four laboratory rats. CONCLUSIONS: We have integrated a kV radiographic and tomographic imaging system with a medical linear accelerator to allow localization of bone and soft-tissue structures in the reference frame of the accelerator. Modeling and experiments have demonstrated the feasibility of acquiring high-quality radiographic and tomographic images at acceptable imaging doses. Full integration of the kV and MV imaging systems with the treatment machine will allow on-line radiographic and tomographic guidance of field placement.

Animals↗

Dose-volume analysis for quality assurance of interstitial brachytherapy for breast cancer.

PURPOSE/OBJECTIVE: The use of brachytherapy in the management of breast cancer has increased significantly over the past several years. Unfortunately, few techniques have been developed to compare dosimetric quality and target volume coverage concurrently. We present a new method of implant evaluation that incorporates computed tomography-based three-dimensional (3D) dose-volume analysis with traditional measures of brachytherapy quality. Analyses performed in this fashion will be needed to ultimately assist in determining the efficacy of breast implants. METHODS AND MATERIALS: Since March of 1993, brachytherapy has been used as the sole radiation modality after lumpectomy in selected protocol patients with early-stage breast cancer treated with breast-conserving therapy. Eight patients treated with high-dose-rate (HDR) brachytherapy who had surgical clips outlining the lumpectomy cavity and underwent computed tomography (CT) scanning after implant placement were selected for this study. For each patient, the postimplant CT dataset was transferred to a 3D treatment planning system. The lumpectomy cavity, target volume (lumpectomy cavity plus a 1-cm margin), and entire breast were outlined on each axial slice. Once all volumes were entered, the programmed HDR brachytherapy source positions and dwell times were imported into the 3D planning system. Using the tools provided by the 3D planning system, the implant dataset was then registered to the visible implant template in the CT dataset. The distribution of the implant dose was analyzed with respect to defined volumes via dose-volume histograms (DVH). Isodose surfaces, the dose homogeneity index, and dosimetric coverage of the defined volumes were calculated and contrasted. All patients received 32 Gy to the entire implanted volume in 8 fractions of 4 Gy over 4 days. RESULTS: Three-plane implants were used for 7 patients and a two-plane implant for 1 patient. The median number of needles per implant was 16.5 (range 11-18). Despite visual verification by the treating physician that surgical clips (with an appropriate margin) were within the boundaries of the implant needles, the median proportion of the lumpectomy cavity that received the prescribed dose was only 87% (range 73-98%). With respect to the target volume, a median of only 68% (range 56-81%) of this volume received 100% of the prescribed dose. On average, the minimum dose received by at least 90% of the target volume was 22 Gy (range 17.3-26.9), which corresponds to 69% of the prescribed dose. CONCLUSION: Preliminary results using our new technique to evaluate implant quality with CT-based 3D dose-volume analysis appear promising. Dosimetric quality and target volume coverage can be concurrently analyzed, allowing the possibility of evaluating implants prospectively. Considering that target volume coverage may be suboptimal even after radiographically verifying accurate implant placement, techniques similar to this need to be developed to ultimately determine the true efficacy of brachytherapy in the management of breast cancer.

Brachytherapy↗

The use of active breathing control (ABC) to reduce margin for breathing motion.

PURPOSE: For tumors in the thorax and abdomen, reducing the treatment margin for organ motion due to breathing reduces the volume of normal tissues that will be irradiated. A higher dose can be delivered to the target, provided that the risk of marginal misses is not increased. To ensure safe margin reduction, we investigated the feasibility of using active breathing control (ABC) to temporarily immobilize the patient's breathing. Treatment planning and delivery can then be performed at identical ABC conditions with minimal margin for breathing motion. METHODS AND MATERIALS: An ABC apparatus is constructed consisting of 2 pairs of flow monitor and scissor valve, 1 each to control the inspiration and expiration paths to the patient. The patient breathes through a mouth-piece connected to the ABC apparatus. The respiratory signal is processed continuously, using a personal computer that displays the changing lung volume in real-time. After the patient's breathing pattern becomes stable, the operator activates ABC at a preselected phase in the breathing cycle. Both valves are then closed to immobilize breathing motion. Breathing motion of 12 patients were held with ABC to examine their acceptance of the procedure. The feasibility of applying ABC for treatment was tested in 5 patients by acquiring volumetric scans with a spiral computed tomography (CT) scanner during active breath-hold. Two patients had Hodgkin's disease, 2 had metastatic liver cancer, and 1 had lung cancer. Two intrafraction ABC scans were acquired at the same respiratory phase near the end of normal or deep inspiration. An additional ABC scan near the end of normal expiration was acquired for 2 patients. The ABC scans were also repeated 1 week later for a Hodgkin's patient. In 1 liver patient, ABC scans were acquired at 7 different phases of the breathing cycle to facilitate examination of the liver motion associated with ventilation. Contours of the lungs and livers were outlined when applicable. The variation of the organ positions and volumes for the different scans were quantified and compared. RESULTS: The ABC procedure was well tolerated in the 12 patients. When ABC was applied near the end of normal expiration, the minimal duration of active breath-hold was 15 s for 1 patient with lung cancer, and 20 s or more for all other patients. The duration was greater than 40 s for 2 patients with Hodgkin's disease when ABC was applied during deep inspiration. Scan artifacts associated with normal breathing motion were not observed in the ABC scans. The analysis of the small set of intrafraction scan data indicated that with ABC, the liver volumes were reproducible at about 1%, and lung volumes to within 6 %. The excursions of a "center of target" parameter for the livers were less than 1 mm at the same respiratory phase, but were larger than 4 mm at the extremes of the breathing cycle. The inter-fraction scan study indicated that daily setup variation contributed to the uncertainty in assessing the reproducibility of organ immobilization with ABC between treatment fractions. CONCLUSION: The results were encouraging; ABC provides a simple means to minimize breathing motion. When applied for CT scanning and treatment, the ABC procedure requires no more than standard operation of the CT scanner or the medical accelerator. The ABC scans are void of motion artifacts commonly seen on fast spiral CT scans. When acquired at different points in the breathing cycle, these ABC scans show organ motion in three-dimension (3D) that can be used to enhance treatment planning. Reproducibility of organ immobilization with ABC throughout the course of treatment must be quantified before the procedure can be applied to reduce margin for conformal treatment.

Feasibility Studies↗

A model to accumulate fractionated dose in a deforming organ.

PURPOSE: Measurements of internal organ motion have demonstrated that daily organ deformation exists throughout the course of radiation treatment. However, a method of constructing the resultant dose delivered to the organ volume remains a difficult challenge. In this study, a model to quantify internal organ motion and a method to construct a cumulative dose in a deforming organ are introduced. METHODS AND MATERIALS: A biomechanical model of an elastic body is used to quantify patient organ motion in the process of radiation therapy. Intertreatment displacements of volume elements in an organ of interest is calculated by applying an finite element method with boundary conditions, obtained from multiple daily computed tomography (CT) measurements. Therefore, by incorporating also the measurements of daily setup error, daily dose delivered to a deforming organ can be accumulated by tracking the position of volume elements in the organ. Furthermore, distribution of patient-specific organ motion is also predicted during the early phase of treatment delivery using the daily measurements, and the cumulative dose distribution in the organ can then be estimated. This dose distribution will be updated whenever a new measurement becomes available, and used to reoptimize the ongoing treatment. RESULTS: An integrated process to accumulate dosage in a daily deforming organ was implemented. In this process, intertreatment organ motion and setup error were systematically quantified, and incorporated in the calculation of the cumulative dose. An example of the rectal wall motion in a prostate treatment was applied to test the model. The displacements of volume elements in the rectal wall, as well as the resultant doses, were calculated. CONCLUSION: This study is intended to provide a systematic framework to incorporate daily patient-specific organ motion and setup error in the reconstruction of the cumulative dose distribution in an organ of interest. The realistic dose distribution in an organ of interest gives the true dose-volume relationship, and may play an important role in the evaluation of the dose response of human organs. Dose reconstruction during the course of treatment delivery can also be used as an important feedback for the online optimization of individual treatment plans.

Biomechanical Phenomena↗

Use of three-dimensional radiation therapy planning tools and intraoperative ultrasound to evaluate high dose rate prostate brachytherapy implants.

PURPOSE: We performed a pilot study to evaluate the quality of high dose rate (HDR) prostate implants using a new technique combining intraoperative real-time ultrasound images with a commercially available 3-dimensional radiation therapy planning (3D RTP) system. METHODS AND MATERIALS: Twenty HDR prostate implants performed by four different physicians on a phase I/II protocol were evaluated retrospectively. Radiation therapy (RT) consisted of pelvic external beam RT (EBRT) to a dose of 46 Gy in 2-Gy fractions over 5 weeks and 2 HDR implants (prescribed dose of 950 cGy per implant). Our in-house real-time geometric optimization technique was used in all patients. Each HDR treatment was delivered without moving the patient. Ultrasound image sets were acquired immediately after needle placement and just prior to HDR treatment. The ultrasound image sets, needle and source positions and dwell times were imported into a commercial computerized tomography (CT) based 3D RTP system. Prostate contours were outlined manually caudad to cephalad. Dose-volume histograms (DVHs) of the prostate were evaluated for each implant. RESULTS: Four patients with stage T2a carcinoma, 4 with stage T2b, and 3 with stage T1c were studied. The median number of needles used per implant was 16 (range 14-18). The median treated volume of the implant (volume of tissue covered by the 100% isodose surface) was 82.6 cc (range 52.6-96.3 cc). The median target volume based on the contours entered in the 3D RTP system was 44.83 cc (range 28.5-67.45 cc). The calculated minimum dose to the target volume was 70% of the prescribed dose (range 45-97%). On average 92% of the target volume received the prescribed dose (range 75-99 %). The mean homogeneity index (fraction of the target volume receiving between 1.0 to 1.5 times the prescribed dose) was 80% or 0.8 (range 0.55-0.9). These results compare favorably to recent studies of permanent implants which report a minimum target volume dose of 43% (range 29-50%) and an average of 85% of the target volume (range 76-92%) receiving the prescribed dose. CONCLUSIONS: The feasibility of evaluating HDR prostate implants using ultrasound images (acquired immediately prior to treatment) with a commercially available 3D RTP system was established. The dosimetric characteristics of these HDR implants appear to be substantially different compared to permanent implants. These developments allow quantitative evaluation of the dosimetric quality of HDR prostate treatments. Future studies will examine any correlation between the dosimetric quality of the implant and clinical/biochemical outcomes.

Brachytherapy↗

Managing geometric uncertainty in conformal intensity-modulated radiation therapy.

The geometric precision of radiotherapy treatments must increase if the objectives of dose escalation and increased disease control are to be achieved. There are multiple strategies for increasing the geometric precision of a radiotherapy treatment system, including immobilization and setup aids for reducing random and systematic components of setup errors and organ motion alike. Alternatively, more complex strategies can be implemented based on additional information acquired over the course of treatment. Generally, these strategies can be divided into two categories: off-line and on-line. The strategies that are implemented in the clinic must consider the required geometric precision for a given treatment. From this specification, it is possible to select the appropriate strategies and approaches. The cost associated with each approach must also be considered. Once a system for delivery has been designed, the residual uncertainties must still be considered in the planning process. Parallel to the development of strategies for reducing uncertainty, progress is being made in better relating these residual uncertainties to margins for use in treatment planning. This article reviews advances in reducing uncertainty.

Cost-Benefit Analysis↗

A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager.

Spatial and temporal imaging characteristics of an amorphous silicon flat-panel imager (FPI) were investigated in terms relevant to the application of such devices in cone-beam computed tomography (CBCT) and other x-ray imaging modalities, including general radiography, fluoroscopy, mammography, radiotherapy portal imaging, and nondestructive testing. Specifically, issues of image lag (including the magnitude, spatial uniformity, temporal-frequency characteristics, and dependence upon exposure and frame time) and long-term image persistence ("ghosts") were investigated. As part of the basic characterization of the FPI, pixel dark signal and noise (magnitude, temporal stability, and spatial uniformity) as well as radiation response (signal size, linearity, gain, and reciprocity) were also measured. Image lag was analyzed as a function of frame time and incident exposure. First-frame lag (i.e., the relative residual signal in the first frame following readout of an exposure) was approximately 2-10%, depending upon incident exposure and was spatially nonuniform to a slight degree across the FPI; second-, third-, and fourth-frame lag were approximately 0.7%, 0.4%, and 0.3%, respectively (at 25% sensor saturation). Image lag was also analyzed in terms of the temporal-frequency-dependent transfer function derived from the radiation response, allowing a quantitative description of system components contributing to lag. Finally, the contrast of objects as a function of time following an exposure was measured in order to examine long-term image persistence ("ghosts"). Ghosts were found to persist up to 30 min or longer, depending upon the exposure and frame time. Two means of reducing the apparent contrast of ghost images were tested: (i) rapid scanning of the FPI at maximum frame rate, and (ii) flood-field exposure of the FPI; neither was entirely satisfactory. These results pose important considerations for application of FPIs in CBCT as well as other x-ray imaging modalities. For example in CBCT, the magnitude of image lag is such that significant artifacts in tomographic reconstructions may result if strategies are not adopted either to reduce or correct the lag between successive projections (e.g., rapid scanning between projections or iterative correction algorithms, respectively). Similarly, long-term image persistence may necessitate frequent recalibration of offset corrections.

Biophysical Phenomena↗

Cone-beam computed tomography with a flat-panel imager: effects of image lag.

A system for cone-beam computed tomography (CBCT) has been developed based upon the technology of active matrix flat-panel imagers (FPIs), and the system has demonstrated the potential for fully three-dimensional volumetric imaging with high spatial and contrast resolution. This paper investigates the effects of image lag (arising from charge trapping and release in the FPI pixels) upon CBCT reconstructions. Hypotheses were derived based upon a simple, geometrical/physical model, suggesting that image lag in the projection data results primarily in two artifacts: a spatial blurring artifact in the direction opposite to the direction of rotation (called a "comet") and a line artifact along the direction of the first few projections (called a "streak"). The hypotheses were tested by means of computer simulations and experimental measurements that yielded CBCT images of a simple cylindrical water phantom containing an attenuating rod of varying size and composition. The computer simulations generated projection images based upon analysis of the system geometry and a simple model of the FPI that allowed free adjustment of the image lag. Experimental measurements involved CBCT scans of the phantom under various conditions and modes of acquisition followed by examination of the resulting CBCT axial slices for lag artifacts. Measurements were performed as a function of exposure level, position and contrast of the rod, and for three modes of acquisition designed to isolate and/or minimize the two hypothesized artifacts. The results clearly illustrate the comet and streak artifacts, particularly in relation to high-contrast objects imaged at high exposure levels. The significance of such artifacts under clinical conditions is expected to be small, considering the magnitude of the effect relative to the morphology and composition of typical anatomy. The artifacts may become appreciable, however, in the presence of high-contrast objects, such as marker BBs, dental fillings, and metal prosthetics. A procedural method of reducing lag artifacts is demonstrated.

Computer Simulation↗

Implementation of 3D-virtual brachytherapy in the management of breast cancer: a description of a new method of interstitial brachytherapy.

PURPOSE: We present the initial description of a new technique of interstitial breast brachytherapy in which a computer-generated image of an implant template is applied virtually to serial-computed tomography (CT) scan images of a patient's breast. Optimal placement of the virtual template around the CT images of the proposed target volume provides the physician with a preplan for improved positioning of implant needles around the actual target volume intraoperatively. METHODS AND MATERIALS: Since March of 1993, 110 patients with early-stage breast cancer were entered onto a protocol of low or high dose rate brachytherapy as the sole radiation modality for part of their breast-conserving therapy. To improve the accuracy and reproducibility of target volume coverage in patients with a closed lumpectomy cavity, 11 of these implants were performed using the virtual brachytherapy technique. The virtual implant procedure was performed by first placing radiopaque skin markers on the breast surface for reference on the CT image and ultimately as intraoperative landmarks for the placement of implant needles. A CT scan of the breast was then performed and the target volume outlined on each CT scan slice by the physician. A virtual image of the brachytherapy template was then positioned around the CT image of the target volume to achieve an idealized implant with optimal coverage. The projected entrance and exit points of all needles on the skin of the breast (from the idealized virtual implant) were then identified (by perspective rendering of multiple 3D views) and hard-copy images taken to the operating room. The implant was then constructed by referencing the virtual implant images (needle entrance and exit points) to the radiopaque skin markers on the breast. After the implant was completed, a CT scan of the breast with the template catheters or needles in position was taken for comparison of the actual target volume coverage with the virtual implant generated preoperatively. RESULTS: Intraoperative ultrasound was used to check the real-time position of the afterloading needles in reference to the chest wall and posterior border of the target volume. No adjustment of needles was required in any of the 11 patients. Assessment of target volume coverage between the virtual implant and the actual CT image of the implant showed excellent agreement. In each case, all target volume boundaries specified by the physician were adequately covered. The total number of implant planes, intertemplate separation, and template orientation were identical between the virtual and real implant. CONCLUSION: We conclude that 3D virtual brachytherapy may offer an improved technique for accurately performing interstitial implants of the breast with a closed lumpectomy cavity in selected patients. Although preliminary results show excellent coverage of the desired target volume, additional patients will be required to establish the reproducibility of this technique and its practical limitations.

Brachytherapy↗