Lactate detection at 3T: compensating J coupling effects with BASING.

Detection of lactate by in vivo 1H magnetic resonance spectroscopy may provide a means of identifying regions of metabolic stress in brain and other human tissue, potentially identifying regional ischemia in stroke or necrosis in tumors. At higher field strengths (3 and 4 T), which have recently become available for whole-body human studies, the chemical shift difference between the doublet from the methyl protons and the quartet from the methine proton becomes comparable to the available radiofrequency (RF) pulse bandwidth. In this case "anomalous" J modulation occurs in PRESS and STEAM because the coupling partner of the observed resonance may or may not be refocused by the RF pulses depending on the position of the molecule within the voxel and the size of the chemical shift misregistration artifact. These anomalies lead to signal cancellation for echo times near odd multiples of 1/J (often used to highlight the inverted lactate doublet against nearby lipid peaks) in single voxel studies, and spatial variation of the doublet lineshape in chemical shift imaging studies, producing erroneous determination of relative lactate concentrations. While increasing the band-width of the RF pulses can reduce this effect by reducing the signal cancellation, some cancellation will always remain. A means of eliminating this effect using BASING/ MEGA (Mescher M et al. Solvent suppression using selective echo dephasing J Magn Reson A 1996;123:226-229; Star-Lack J et al. Improved water and lipid suppression for 3D PRESS CSI using RF band selective inversion with gradient dephasing (BASING). Magn Reson Med 1997;38: 311-321) water suppression pulses will be described, along with some of its limitations.

Humans↗

Very-high-field magnetic resonance imaging: instrumentation and safety issues.

Because of their advantage in terms of signal-to-noise ratio, high-field magnetic resonance imaging systems have become favored in the last few years for functional magnetic resonance imaging (fMRI) applications. In many ways the conceptual development of these high-field scanners has involved more-or-less straightforward extensions of practices at lower field strengths. However, in other ways specific engineering challenges have been encountered and largely overcome in the quest for scanners capable of realizing the advantages of high-field systems. An understanding of the technical trade-offs that can be made in terms of hardware performance is useful in deciding on the optimum system for a given fMRI application. In this article the technical issues surrounding high-field scanning are reviewed in the context of a typical brain mapping protocol. In addition there is a discussion of the safety issues related to the use of these systems.

Brain Mapping↗

Chemical shift imaging of human brain: axial, sagittal, and coronal P-31 metabolite images.

Multivoxel magnetic resonance (MR) spectroscopy and novel data analysis techniques were developed to obtain high-quality phosphorus-31 metabolite images from the human brain and to overlay each metabolite distribution directly onto corresponding hydrogen-1 MR images. The P-31 MR spectroscopic data were acquired by means of three-dimensional chemical shift imaging (phase encoding in three spatial dimensions) on a 1.5-T clinical instrument equipped with a specially designed quadrature P-31 birdcage coil constructed in the authors' laboratory. Axial, sagittal, and coronal metabolite images based on the area for any one of five peak regions (phosphodiester; phosphocreatine; gamma, alpha, and beta adenosine triphosphate) were generated from 8 X 8 X 8 or 12 X 12 X 8 CSI arrays with voxel sizes of 27 cm3 and 12 cm3, respectively. The positions of these images were aligned with anatomic features by means of the voxel-shifting capability of the Fourier transform. Direct overlays of these metabolite images on corresponding proton images demonstrated excellent correlation with anatomy, factors indicating the utility of this technique for viewing P-31 metabolite levels in all areas of the brain simultaneously.