PubMed HealthSearch

Biomedical subjects

D A Pay

Publications and source records attributed to D A Pay.

4 recordsLinked to original sources

A practical method of serial bedside measurement of cerebral blood flow and metabolism during neurointensive care.

Acute encephalopathy is a major cause of death and neurological handicap in children. The principle aims of treatment are to provide adequate cerebral blood flow for the brain's metabolic needs and to prevent intracranial pressure rising above the level at which brain herniation occurs. Rational management requires an understanding of the pathophysiological changes in cerebral blood flow and metabolism which occur. The paucity of data on this subject reflects the perceived difficulty of measuring cerebral blood flow and cerebral metabolism in children. A modification of the Kety Schmidt technique of measuring cerebral blood flow and cerebral metabolism is described. This modification makes it possible to perform serial bedside measurements in children receiving intensive care. This method was used to perform 348 measurements in 58 children. The method was reproducible and no significant complications were encountered. The results indicated that appreciable changes in cerebral blood flow and metabolism could occur in individual patients over time, emphasising the importance of serial measurements. This technique may provide a practical means of monitoring cerebral blood flow and metabolism in very sick children receiving neurointensive care and evaluating the efficacy of treatment.

Acute Disease

Diabetes mellitus and open heart surgery. A simple, practical closed-loop insulin infusion system for blood glucose control.

A method, based on bedside determinations of blood glucose by nursing staff, was designed to control the administration of insulin to diabetic patients during and following open heart surgery. A computer-controlled intravenous infusion pump was used to deliver the insulin. Excellent control of the hyperglycaemia normally associated with open heart surgery was achieved, with 84 percent of measured blood glucose values falling within 2 mmol/litre of the target value of 6 mmol/litre. The method proved to be simple, effective, and safe.

Adult

Practical closed-loop insulin infusion.

A method was designed to control the insulin infusion given to diabetic patients at the time of open-heart surgery. Excellent control of the blood glucose concentration was achieved, with eighty-four percent of blood glucose values falling between 4 and 8 mmol/l.

Adult

A system for peri-operative blood glucose control in diabetes mellitus.

A pocket computer has been programmed to control the rate of administration of insulin given to diabetic patients having open heart surgery. Twelve diabetic patients were studied. Five had coronary artery bypass grafting, and seven had heart valve surgery. During operation 122 out of 162 (75%), and post-operatively 291 out of 360 (81%) blood glucose concentrations were between 4.0 and 8.0 mmol l-1. Five hundred and fifteen values out of 552 (99%) were below 12.0 mmol l-1. There was no hypoglycaemia. The lowest measured blood glucose concentration was 3.7 mmol l-1. The computer is readily available, easy to use by inexperienced personnel, and cheap.

Adult