PubMed Health⌕ Search

Biomedical subjects

D A Rüfenacht

Publications and source records attributed to D A Rüfenacht.

At least 19 recordsLinked to original sources

Anomalous intracranial drainage of the nasal mucosa: a vein of the foramen caecum?

The existence of the vein of the foramen caecum (VFC) in humans is still controversial. We present 2 patients with intracranial drainage of the nasal mucosa by a frontal cortical vein into a superior sagittal sinus, demonstrated by digital subtraction angiography. In both, the position of the intracranial passage was found to be slightly paramedian. An analogy to the VFC is made.

Adult↗

Conformability of balloon-expandable stents to the carotid siphon: an in vitro study.

BACKGROUND AND PURPOSE: Endovascular placement of coronary balloon-expandable stents in patients with recurrent cerebral ischemia has emerged as a treatment option for intracranial arterial occlusive disease. We have developed an in vitro model matching the tortuous curve of the carotid siphon that allows the assessment of apposition of stents to a curved vessel wall. METHODS: Six types of balloon-expandable coronary stents were implanted in a silicone model of the carotid siphon. Digital radiographs and 3D rotational angiograms were obtained. Stent morphology was evaluated and the degree of apposition between stent and wall of the model was measured on a digital workstation. RESULTS: All 6 stents showed lack of apposition between stent and the wall at the convexity of the anterior segment of the carotid siphon and the wall at the concavity at both extremities of the stent. In and around the curve, the modules of the stents did not expand completely to their nominal diameter and were distorted to an oval shape. CONCLUSION: The tested coronary balloon-expandable stents did not completely conform to the vessel wall of the model of the carotid siphon and further development is needed to approach the goal of an "ideal intracranial stent."

Angiography, Digital Subtraction↗

The perianeurysmal environment: influence on saccular aneurysm shape and rupture.

PURPOSE: The purpose of this study was to evaluate whether interactions between intracranial cerebral saccular aneurysms and the perianeurysmal environment (PAE), in the form of contact constraints, influence aneurysm shape and risk of rupture. METHODS: A total of 190 consecutive aneurysms during a 34-month period were retrospectively analyzed. Of these, 124 were ruptured (group 1) and 66 were unruptured (group 2). Pretreatment high-resolution CT angiography was available for each aneurysm and was the determinant inclusion criterion. Aneurysm size and location, type of hemorrhage, initial Glasgow Coma Scale rating, World Federation of Neurological Societies grade, Fisher grade, and presence of concomitant aneurysms were recorded. Contact constraints between aneurysms and anatomical structures of the PAE were identified for each aneurysm and further subdivided into balanced or unbalanced depending on whether contact constraints occurred symmetrically on the aneurysm wall. Regular or irregular shape was recorded and correlated to contact constraints. RESULTS: Compared with unruptured aneurysms, ruptured aneurysms were found to be larger and more irregular, to develop more contact constraints with the PAE, and to show higher rates of unbalanced contact constraints. Ruptured aneurysms had a tendency to be found in locations of a constraining PAE. Irregular shape was positively correlated with the presence of an unbalanced contact constraint, even in the absence of obvious contour deformations from an imprint of an adjacent structure. CONCLUSION: The existence of contact constraints between intracranial saccular aneurysms and the PAE were shown to influence shape and risk of aneurysm rupture. Modifications of wall shear stress by contact constraints are discussed. Analysis of contact constraints between aneurysm and the PAE could be considered additional parameters in the assessment of risk of aneurysm rupture.

Aneurysm, Ruptured↗

Embolization of experimental wide-necked aneurysms with iodine-containing polyvinyl alcohol solubilized in a low-angiotoxicity solvent.

BACKGROUND AND PURPOSE: To evaluate the ready-to-use iodine-containing polyvinyl alcohol (I-PVA) dissolved in the low angiotoxic solvent N-methyl pyrrolidone (NMP) for embolization of porcine wide-necked aneurysms. METHODS: Fourteen broad-based carotid sidewall aneurysms were surgically constructed in 7 swine. I-PVA (40%) in NMP was injected under temporary balloon occlusion bridging the aneurysm neck. After 4 weeks, follow-up angiography, multisection CT angiography (MSCTA), and 3T MR imaging including MR angiography (MRA) sequences were performed. Afterward, harvested aneurysms were investigated histopathologically. RESULTS: The liquid embolic was well visible under fluoroscopy and displayed a favorable precipitation pattern, allowing for controlled polymer delivery. Ten aneurysms (71%) were initially completely occluded, whereas in 1 aneurysm, a minimal polymer leakage was observed. The other 4 aneurysms (29%) were almost completely occluded. One animal suffered a lethal rebleeding from the anastomosis after uneventful embolization. Aneurysms embolized with I-PVA could be discriminated well from the parent artery without beam-hardening artifacts on MSCTA, and no susceptibility artifacts were encountered on MR imaging. Histologic examination revealed all aneurysms covered with a membrane of fibroblasts and an endothelial cell layer while a moderate intraaneurysmal inflammatory response to the polymer was observed. CONCLUSION: I-PVA dissolved in NMP has proved its effectiveness for the embolization of experimental wide-necked aneurysms. This precipitating liquid embolic offers several interesting features in that it needs no preparation before use and no radiopaque admixtures, the latter allowing for artifact-free evaluation of treated aneurysms with MSCTA and MRA. Moreover, it uses NMP as a solvent, which has only a low angiotoxicity.

Animals↗

Organic solvents as vehicles for precipitating liquid embolics: a comparative angiotoxicity study with superselective injections of swine rete mirabile.

BACKGROUND AND PURPOSE: The organic solvent dimethyl-sulfoxide (DMSO), as a commonly used vehicle for nonadhesive liquid embolics, is not devoid of local angiotoxic effects. We compared microvascular toxicities of superselective infusions of DMSO with potentially more compatible solvents in swine rete mirabile. METHODS: Fourteen swine underwent angiography for superselective catheterization of 28 arteries of the rete while electrocardiography and intra-arterial pressure were continuously monitored. The investigated solvents were DMSO, dimethyl isosorbide (DMI), ethyl lactate, glycofurol 75, N-methyl pyrrolidone (NMP), and solketal. Control infusion of saline ruled out catheter induced vasospasm in all cases. Each artery of the rete was infused only once with 0.8 mL of one of the solvents over 60 seconds. Acute angiographic and hemodynamic consequences were evaluated. Blood samples were assessed for signs of intravascular hemolysis. Brains and retia were harvested for gross and histopathologic investigation. RESULTS: On the basis of the angiographic data, DMSO induced the most pronounced vasospasm with the longest recovery period of all solvents investigated. Ethyl lactate, glycofurol 75, and solketal elicited less severe vasospasms and accordingly resolved much more quickly. DMI and NMP induced only minimal vasospasms with comparably short duration. No solvent caused significant hemodynamic alterations or hemolysis. Gross inspection of brains showed no abnormalities, whereas histopathologic examination revealed mostly nonspecific findings. One rete exposed to solketal displayed possible causal histotoxic changes. CONCLUSION: DMI and NMP produced far less vasospasm than DMSO. No changes in hemodynamic or hemolytic parameters and no histopathologic findings were observed with infusion of these solvents.

Alkenes↗

White matter lesions in watershed territories studied with MRI and parenchymography: a comparative study.

Brain aging affects an increasing segment of the population and the role of chronic cerebrovascular disease is considered to be one of the main parameters involved. For this purpose we compared retrospectively MRI data with digitized subtraction angiography (DSA) data in a group of 50 patients focusing onto the watershed area of the carotid artery vascular territories. In order to evaluate the presence of white matter lesions (WML) in the hemispheric watershed areas, coronal fluid-attenuated inversion-recovery or axial T2 weighted MRI images of patients with symptomatic cerebrovascular insufficiency areas were compared with the capillary phase of DSA studies in anterior-posterior projection. Presence of cerebrovascular occlusive disease was evaluated on DSA using North American symptomatic carotid endarterectomy trial criteria and including evaluation of collateral vascular supply. Pathological MRI findings in the region of the watershed territories correlated overall in 66% of cases with a defect or delayed filling on DSA. In the case of asymmetrical MRI findings, there was a pathological finding of the capillary phase in the watershed area in 92% of DSA studies. Hypoperfusion in the capillary phase of the watershed area as seen on DSA correlated with the stenosis degree of the concerned carotid artery. Our findings suggest that asymmetrical findings of WML in the watershed areas as seen on MRI are caused by hemodynamic effect and a differentiation between small vessel disease and a consequence of distant stenosis may be possible under such conditions.

Aged↗

Intraarterial thrombolysis and stent placement in the acute phase of blunt internal carotid artery trauma with subocclusive dissection and thromboembolic complication: case report and review of the literature.

The case of a patient with blunt traumatic internal carotid artery dissection associated with subocclusive stenosis and thromoboembolic complication is presented. The patient suffered fluctuant neurological abnormalities and several open and closed fractures of the left limb. The vascular lesion and its complication were successfully treated with intraarterial thrombolysis and stent placement during the acute phase, prior to the open surgical treatment of the fractures.

Arterial Occlusive Diseases↗

ADC mapping of the aging frontal lobes in mild cognitive impairment.

Normal aging, leukoaraiosis (LA) and vascular disease particularly involve the human frontal lobes. We decided to investigate a population of elderly patients referred for neuroimaging because of progressive minor cognitive deficits but no dementia. They underwent conventional Magnetic resonance imaging (MRI) using axial T1 and T2-weighted imaging as well as coronal FLAIR sequences in addition to the axial diffusion-weighted MRI. MRI allowed us to differentiate patients with leukoaraïosis (LA+) from those without it (LA-) and mapping of the apparent diffusion coefficient (ADC) to investigate local tissular water motion. We observed an increase in the ADC in all investigated patients with increasing age (r=0.326, p=0.002). This increase was observed in both patients groups (LA+ and LA-). In addition, the LA+ group had significant higher ADC values than the LA- group after controlling for age (p<0.0001).

Adult↗

Radiation dose in vertebroplasty.

We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements.

Aged↗

Spiral versus J-shaped coils for neurovascular embolisation-an in-vitro study.

Our purpose was to compare the characteristics of J-shaped detachable platinum coils with those of spiral coils in in-vitro vascular models. J-shaped coils consist of distal semicircular and proximal straight segments, the latter extending for most of the length of the coil. Spiral coils have a helical shape memory and are thus limited in expansion. In in-vitro silicone vascular models simulating intracranial aneurysms and dural arteriovenous fistulae, we compared J-shaped and spiral coils with regard to ease of delivery, anchoring and folding patterns, and stability in various types of vascular lumen. Delivery and retrieval were comparable. In large and irregular aneurysms and venous sinuses, J-shaped coils could form a more complex basket which conformed to the shape of the vascular cavity. The J-shaped coil was always in contact with the vessel wall. In wide-necked aneurysms, coil protrusion was more frequent with J-shaped coils, while spiral coils tended to stay compact and circular. Arteries were occluded in a shorter segment with spiral coils. J-shaped coils were safe and superior for large and irregular aneurysms or sinuses. Spiral coils were preferable for spherical aneurysms and segmental occlusion of arteries.

Angiography↗

CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study.

The purpose of our experimental study was to assess the accuracy and precision of CT angiography (CTA), MR angiography (MRA) and rotational digital subtraction angiography (DSA) for measuring the volume of an in vitro aneurysm model. A rigid model of the anterior cerebral circulation harbouring an anterior communicating aneurysm was connected to a pulsatile circuit. It was studied using unenhanced 3D time-of-flight MRA, contrast-enhanced CTA and rotational DSA angiography. The source images were then postprocessed on dedicated workstations to calculate the volume of the aneurysm. CTA was more accurate than MRA (P=0.0019). Rotational DSA was more accurate than CTA, although the difference did not reach statistical significance (P=0.1605), and significantly more accurate than MRA (P<0.00001). CTA was more precise than MRA (P=0.12), although this did not reach statistical significance. Rotational DSA can be part of the diagnosis, treatment planning and support endovascular treatment of intracranial aneurysms. The emerging endovascular treatment techniques which consist of using liquid polymers as implants to exclude aneurysms from arterial circulation would certainly benefit from this precise measurement of the volume of aneurysms.

Angiography, Digital Subtraction↗

Intraorbital ophthalmic artery aneurysm associated with basilar tip saccular aneurysm.

We present a rare case of intraorbital ophthalmic artery aneurysm found incidentally, together with a ruptured aneurysm of the tip of the basilar artery. The intraorbital aneurysm was asymptomatic, and no treatment was offered. Angiographic control was recommended to detect any progression. Treatment may be indicated for documented enlargement or significant mass effect of the aneurysm.

Adult↗

Is the rupture of cerebral berry aneurysms influenced by the perianeurysmal environment?

PURPOSE: To evaluate contact between cerebral berry aneurysms and the perianeurysmal environment and to study the influence this contact has on aneurysm rupture. MATERIALS AND METHODS: In a series of 76 consecutive patients, pre- and post-contrast CT images of 87 aneurysms were evaluated. Aneurysm locations were identified and aneurysms were divided into two different groups depending on whether they had ruptured or not. Contact between aneurysms and the perianeurysmal environment was studied when present, and considered to be balanced or unbalanced according to symmetry of contact and type of contact interface, i.e. with bone, dura, etc. RESULTS: Rupture occurred in 47 aneurysms at an average maximum dome size of 7.4 mm. There was contact with elements of the perianeurysmal environment in 38 (81%) of ruptured cases and no evidence of contact in 7 (15%). The nature of contact was unclear in 2 (4%) ruptured aneurysms. In the aneurysms with contact, the nature of contact was unbalanced in 34 (72%) and balanced in 4 (9%). Unbalanced aneurysms ruptured at significantly smaller sizes (average: 7.7 mm) than balanced aneurysms (average: 11.4 mm). Seven aneurysms of small size (3.3-6.9 mm, average: 4.8 mm) were found to have ruptured, despite the fact that they were too small to exhibit contact with the perianeurysmal environment. In 40 unruptured aneurysms (average size: 6.3 mm), contact with the perianeurysmal environment was found in 15 aneurysms, for which balanced contact was found in 11 (27.5%) and unbalanced contact in 4 (10%), and no contact in 25 (62.5%). The average size of the aneurysms without contact (3.7 mm) was significantly smaller than that with balanced contact (10.3 mm) or with unbalanced contact (11.3 mm). CONCLUSION: Aneurysms exhibit contact with their perianeurysmal environment as soon as they reach a size that exceeds their allowance given by the local subarachnoid space. The contact with the environment was found to be an additional determinant parameter in the evolution of cerebral berry aneurysms and their risk to rupture.

Adult↗

Performance of long J-shaped coils in large and giant intracranial aneurysms: an in vitro study.

We evaluated the performance of long straight coils (Detach-18 J-shaped coils) in large and giant in-vitro aneurysms. The coils consisted of a distal semicircular part 7 or 15 mm in diameter and a proximal 70 cm straight part having three types of stiffness: soft, standard, and stiff. We first investigated the ease of passage through a microcatheter in a realistic cerebral vessel model. Second, we made silicone models simulating lateral-type aneurysms of various spherical dome diameters (12, 15, 20 and 30 mm) and neck sizes (3-10 mm; dome-to-neck ratio approximately 3:1) and connected them to a pulsating circulatory pump. We evaluated the anchoring and folding patterns of the coils, stability of the microcatheter and coils in the aneurysm, and smoothness of delivery and retrieval of coils. Third, we compared the conformability of a coil in a large, irregular aneurysm with that of a spiral coil. The long J-shaped coils were easily advanced and retrieved through a microcatheter in a tortuous vessel model. In 12 mm spherical aneurysms, each coil made a complex framework, and knot formation or damage to the coil during withdrawal was often observed. In 15 mm aneurysms, the coils were all easily delivered and retrieved; standard-stiffness coils adapted best to this size. In 20 mm aneurysms, frameworks were less complex but still good with a standard or stiff coil, but those with soft coil were unstable and changed significantly within 3 min of detachment due to gravity and pulsatile flow. In 30 mm aneurysms, soft coils filled only the lower part during introduction, whereas a stiff coil still made a favourable framework. Conformability of a long J-shaped coil was superior to that of a spiral coil in a large, irregular aneurysm. Long J-shaped coils conform well to various configurations of large and giant aneurysms and can shorten procedures since a larger implant volume can be delivered with a single coil. Their principle of action may promote more favourable occlusion of irregular and large aneurysms by improved conformability and stability.

Embolization, Therapeutic↗

Stent impact on the geometry of the carotid bifurcation and the course of the internal carotid artery.

A measurement system is proposed to evaluate reconstructive effects of carotid stents on the geometry of the carotid bifurcation and the course of the internal carotid artery. To describe deviations of the stenotic internal carotid artery (ICA) from the extended axis of the common carotid artery (CCA) the CCA-ICA angle is measured between the CCA midaxis and the midaxis of the stenotic ICA segment. Maximal extensions of ICA tortuosities perpendicular to the course of the CCA axis are defined as ICA offset. The measurements were applied to DSA images of 224 carotid stenoses to evaluate variation and correlation between the two parameters. Comparative pre- and post-stent evaluation was performed in two series of 55 and 31 carotid stenoses treated with Wallstents and in a historic control group of 35 stenoses treated with Strecker stents. Straight course of the ICA was associated with low angle and low offset values, whereas tortuous course of the ICA showed larger angle and offset. A moderate linear correlation between the two parameters was found. Corresponding to a straightening of the stented segment, Wallstents reduced mean angle and offset values significantly. In five cases of the second series of Wallstents, transferrals of curves above the distal stent end associated with kinks were observed, and offset remained constant or increased. Strecker stent implantation caused no significant changes of bifurcational geometry. The proposed parameters corresponded to visual aspects of ICA tortuosity and detected reconstructive effects of self-expanding Wallstents on the ICA course. The measurement system may provide a basis for geometric evaluation of different stent types or implantation concepts with the aim: to optimize anatomic recanalization results in tortuous high angle-high offset bifurcations.

Aged↗

Pooling of echographic contrast agents during transcranial Doppler sonography: a sign in favor of slow-flowing giant saccular aneurysms.

Transcranial Doppler (TCD) sonography is a new imaging technique allowing for non-invasive evaluation of the intracranial vascular anatomy and cerebral hemodynamics. The recent introduction of echographic contrast agents has significantly increased the sensitivity of TCD for the diagnosis of intracranial vascular lesions. We report a case of giant AComA aneurysm, undetected by color and power TCD, which became visible after echographic contrast administration as a delayed and persistent area of contrast enhancement. Knowledge of atypical or contrast-specific lesion appearances will become important if contrast-enhanced TCD is to be used routinely in the diagnosis of intracranial aneurysms.

Contrast Media↗

Disappearance of an intracerebral arteriovenous malformation in an HIV-infected patient after initiation of HAART.

HIV infection or complications of HIV-induced immunodeficiency may affect the central nervous system (CNS). However, vascular cerebral pathologies are very rare, in particular intracerebral arteriovenous malformations (AVM). We report the case of an HIV-infected patient who had a cerebral AVM leading to symptoms such as recurring focal seizures. Only after initiation of potent antiretroviral combination therapy, but not antiretroviral monotherapy or bitherapy, could the viral load be suppressed and immunodeficiency resolved. Two years after the start of highly active antiretroviraL therapy (HAART) total occlusion of the AVM could be demonstrated. Taken together, this case report may demonstrate the potent angiogenic activity of HIV for AVM. Also, this case report might show that inhibition of such a cofactor may lead to resolution of an AVM.

Antiretroviral Therapy, Highly Active↗