PubMed Health⌕ Search

Biomedical subjects

D A Reimann

Publications and source records attributed to D A Reimann.

5 recordsLinked to original sources

Human vertebral body apparent and hard tissue stiffness.

Cancellous bone apparent stiffness and strength are dependent upon material properties at the tissue level and trabecular architecture. Microstructurally accurate, large-scale finite element (LS-FE) models were used to predict the experimental apparent stiffness of human vertebral cancellous bone and to estimate the trabecular hard tissue stiffness. Twenty-eight LS-FE models of cylindrical human vertebral cancellous bone specimens (8 mm in diameter, 9.5 mm in height, one each from twenty-eight individuals) were generated directly from microcomputed tomography images and solved by a special purpose iterative finite element program. The experimental apparent stiffness and strength of the specimens were determined by mechanical testing to failure in the infero superior direction. Morphometric measurements including bone volume fraction (BV/TV), three eigenvalues of the fabric tensor and average P(L) were also calculated. The finite element estimate of apparent stiffness explained much of the variance in both experimental apparent stiffness (r2=0.89) and experimental apparent strength (r2=0.87). Stepwise linear regression analysis demonstrated that the LS-FE estimated apparent stiffness was the only significant predictor of experimental apparent stiffness and strength when it was included with all measured morphometric values. Hard tissue stiffness was quite variable between individuals (mean, 5.7 GPa; S.D. 1.6 GPa), but was not significantly related to age, sex, race, weight or morphometric measures for this sample.

Adult↗

A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

The modulation transfer function (MTF) of radiographic systems is frequently evaluated by measuring the system's line spread function (LSF) using narrow slits. The slit method requires precise fabrication and alignment of a slit and high radiation exposure. An alternative method for determining the MTF uses a sharp, attenuating edge device. We have constructed an edge device from a 250-microm-thick lead foil laminated between two thin slabs of acrylic. The device is placed near the detector and aligned with the aid of a laser beam and a holder such that a polished edge is parallel to the x-ray beam. A digital image of the edge is processed to obtain the presampled MTF. The image processing includes automated determination of the edge angle, reprojection, sub-binning, smoothing of the edge spread function (ESF), and spectral estimation. This edge method has been compared to the slit method using measurements on standard and high-resolution imaging plates of a digital storage phosphor (DSP) radiography system. The experimental results for both methods agree with a mean MTF difference of 0.008. The edge method provides a convenient measurement of the presampled MTF for digital radiographic systems with good response at low frequencies.

Computer Simulation↗

Eigenimage filtering in MR imaging: an application in the abnormal chest wall.

A postprocessing linear filter was applied to spin-echo images on 10 patients with known or suspected chest wall invasion due to bronchogenic carcinoma. This technique known as eigenimage filtering allows selective feature extraction of suspected abnormalities from conventional MR images. The final result is an image with marked increased contrast range through enhancement of a desired process (tumor) with suppression of an interfering process (e.g., normal surrounding tissue). This preliminary work demonstrates the ease with which the technique may be implemented, the contrast enhancement obtained between the desired and the interfering feature in the final eigenimage, and its ability to correct for partial volume averaging effects. Also demonstrated are artifacts that can interfere with the interpretation of the eigenimage and a method for minimizing these artifacts in the final eigenimage.

Carcinoma, Bronchogenic↗

A cone beam computed tomography system for true 3D imaging of specimens.

A system for 3D cone beam computed tomography has been developed, consisting of a microfocus x-ray source and x-ray image intensifier coupled to a CCD camera. Full width at half maximum resolving power has been experimentally measured to be 70 microns when imaging 10 mm diameter objects. The 3D nature of the resulting image data can be used to visualize internal structure and compute parameters such as volume, surface area, and surface/volume orientation.

Animals↗

Eigenimage filtering in MR imaging.

This article presents the technical aspects of a linear filter, referred to as eigenimage filtering, and its applications in magnetic resonance (MR) imaging. The technique is used to obtain a single composite image depicting a particular feature of interest while suppressing one or more interfering features. The appropriate weighting components to be used in the linear filter are determined on the criterion that the desired feature is enhanced while the interfering features are suppressed. The criterion is expressed mathematically as a ratio. By applying Rayleigh's principle, the ratio is maximized by finding the eigenvector associated with the maximum eigenvalue of the corresponding generalized eigenvalue problem. The appropriate weighting factors for the linear filter are the elements of the eigenvector which maximize the ratio. The utilization of the technique is demonstrated in its application to a simulated MR image sequence as well as to acquired MR image sequences of a normal and an abnormal brain.

Brain↗