PubMed Health⌕ Search

Biomedical subjects

D A Tanner

Publications and source records attributed to D A Tanner.

6 recordsLinked to original sources

Quantitative TEM analysis of a hexagonal mesoporous silicate structure.

TEM analysis of mesoporous materials is generally undertaken to give qualitative results. Accurate quantitative analysis is demonstrated in this study. A systematic image analysis of a powder form of a hexagonal mesoporous material known as KIT-6 is conducted using a transmission electron microscope (TEM). Three types of image contrast typically appear in this material (a hexagonal honeycomb structure, wide and narrow parallel lines). The honeycomb face is used to characterise this material in terms of a conventional 2-D hexagonal structure and the d-spacings for the (100) and (110) planes are experimentally measured in varying focus conditions. A tilting experiment is conducted to determine how the angle of tilt affects the line spacing and their visibility. Tilting has very little effect on the line spacing, whereas it affects the visibility of both the wide and narrow lines by limiting an angle range of visibility. The hexagonal lattice structure parameter determined by TEM method is found to be approximately 7% lower than that calculated by low-angle X-ray diffraction. Thus we conclude that TEM data can be used to determine the geometry and dimensions of hexagonal mesoporous silica materials, with a small error in the hexagonal lattice parameter.

Computer Simulation↗

Ultrasonically set glass polyalkenoate cements for orthodontic applications.

There is an accepted clinical requirement for a luting cement that can be command set upon satisfactory placement of an orthodontic appliance onto dentition. This work evaluates the suitability of ultrasound, imparted from a dental scaler, as a potential mechanism for achieving this. The net setting times and subsequent compressive strengths of a range of commercial and experimental glass polyalkenoate cements (GPCs) were evaluated, using modified ISO 9917 methods, when set both chemically and by ultrasound. The ultrasound was applied to the GPC through an orthodontic brace. It was possible to command set GPCs by the application of five to ten seconds of ultrasound; the exact time required being dependent upon the composition of the GPC in question. The compressive strengths of these cements can be improved by around 90% with the command set when the optimum PAA molecular weight and tartaric acid content is employed.

Adhesiveness↗

The antibacterial effects of zinc ion migration from zinc-based glass polyalkenoate cements.

Zinc-based glass polyalkenoate cements have been synthesised and their potential use in orthopaedic applications investigated. Zinc ions were released from the materials in a rapid burst over the first 24 h after synthesis, with the release rate falling below detectable levels after 7 days. Cement-implanted bone samples were prepared and the released zinc was shown, using energy dispersive X-ray analysis, to penetrate from the cement into the adjacent bone by up to 40 microm. Finally, the cements exhibited antibacterial activity against Streptococcus mutans and Actinomyces viscosus that reflected the pattern of zinc release, with the inhibition of growth greatest shortly after cement synthesis and little or no inhibition measureable after 30 days.

Actinomyces viscosus↗

Clothing fabric does not affect thermoregulation during exercise in moderate heat.

PURPOSE: We investigated whether temperature regulation is improved during exercise in moderate heat by the use of clothing constructed from fabric that was purported to promote sweat evaporation compared with traditional fabrics. METHODS: Eight well-trained, euhydrated males performed three exercise bouts wearing garments made from an evaporative polyester fabric (SYN), wearing garments made from traditional cotton fabric (COT), or dressed seminude (S-N) in random order. Bouts consisted of 15 min seated rest, 30 min running at 70% .VO(2max), 15 min walking at 40% .VO(2max), and 15 min seated rest, all at 30 +/- 1 degrees C and 35 +/- 5% relative humidity. COT and SYN clothing ensembles consisted of crew neck, short sleeve T-shirts, cycling shorts, and anklet socks made from their respective materials, and running shoes. The S-N condition consisted of a Lycra swim suit, polyester socks, and running shoes. RESULTS: Mean skin temperature was lower for S-N during preexercise rest when compared with SYN and COT. No differences in mean body temperature, rectal temperature, or mean skin temperature were observed during or after exercise. No differences in VO2 or heart rate were observed. No differences in comfort sensations were observed. CONCLUSION: In summary, before, during, or after exercise in a moderately warm environmental condition, neither the addition of a modest amount of clothing nor the fabric characteristics of this clothing alters physiological, thermoregulatory, or comfort sensation responses.

Adult↗

Expiratory flow limitation confounds ventilatory response during exercise in athletes.

INTRODUCTION: A significant number of highly trained endurance runners have been observed to display an inadequate hyperventilatory response to intense exercise. Two potential mechanisms include low ventilatory responsiveness to hypoxia and ventilatory limitation as a result of maximum expiratory flow rates being achieved. PURPOSE: To test the hypothesis that expiratory flow limitation can complicate determination of ventilatory responsiveness during exercise the following study was performed. METHODS/MATERIALS: Sixteen elite male runners were categorized based on expiratory flow limitation observed in flow volume loops collected during the final minute of progressive exercise to exhaustion. Eight flow limited (FL) (VO2max, 75.9+/-2.4 mL x kg(-1) x min(-1); expiratory flow limitation, 47.3+/-20.4%) and eight non-flow limited subjects (NFL) (VO2max, 75.6+/-4.8 mL x kg(-1) x min(-1); expiratory flow limitation, 0.3+/-0.8%) were tested for hypoxic ventilatory responsiveness (HVR). RESULTS: Independent groups ANOVA revealed no significant differences between FL and NFL for VO2max, VE max (136.2+/-16.0 vs 137.5+/-21.6 L x min(-1)), VE/VO2, (28.4+/-3.2 vs 27.6+/-2.9 L x lO2(-1)), VE/VCO2 (24.8+/-3.1 vs 24.4+/-2.0 L x lCO2(-1)), HVR (0.2+/-0.2 vs 0.3+/-0.1 L x %SaO2(-1)), or SaO2 at max (89.1+/-2.4 vs 86.6+/-4.1%). A significant relationship was observed between HVR and SaO2 (r = 0.92, P < or = 0.001) in NFL that was not present in FL. Conversely, a significant relationship between VE/VO2 and SaO2 (r = 0.79, P < or = 0.019) was observed in FL but not NFL. Regression analysis indicated that the HVR-SaO2 and SaO2-VE/VO2 relationships differed between groups. DISCUSSION: When flow limitation is controlled for, HVR plays a more significant role in determining SaO2 in highly trained athletes than has been previously suggested.

Adult↗

Partitioned weight loss and body composition changes during a mountaineering expedition: a field study.

Weight loss and changes in body composition are recognized phenomena associated with high-altitude mountaineering expeditions. Attempts to partition the weight loss between fat mass (FM) and fat-free mass (FFM) have been inconclusive. Therefore, five male subjects, average age 40.0 +/- 5.5 years, were studied prior to, during, and following a 21-day expedition between 2200 m and 4300 m on Mt. McKinley, Alaska. Pre- to postexpedition body composition changes were determined by densitometry, skinfold thickness (12 sites), body girth measurements (14 sites), and cross-sectional area from magnetic resonance imaging (MRI) (three sites). Data analysis by Student's t-test (p < 0.05(1) tail) indicated decreases in body weight (4.2 +/- 2.8 kg, 220 g/day, 5.4% of initial weight), total skinfold thickness (10.8%), total body girth (2.8%), and percentage of fat by densitometry (15%). Total cross-sectional area of the three MRI slices (upper arm + thigh + calf) decreased 4.7%, muscle area decreased 9.1%, and fat area decreased 3.9%. The three methods used to partition the weight loss between FM and FFM did not agree: 77% FM vs 23% FFM by densitometry, 25% FM vs 75% FFM by skinfolds, and 38% FM vs 62% FFM by MRI. Energy intake (3640 +/- 1250 kcal/day) was negatively correlated (Pearson r > 0.88(2) tail) with losses in weight (r = -0.89), skinfolds (r = -0.93), and girths (r = -0.88), ie the greater the intake the less the decline. Therefore, insufficient energy intake appeared primarily responsible for the weight loss and changes in body composition during the expedition.

Absorptiometry, Photon↗