PubMed HealthSearch

Biomedical subjects

D A Wojtasek

Publications and source records attributed to D A Wojtasek.

5 recordsLinked to original sources

Fine-needle aspiration of breast biopsy specimens: correlation of histologic and cytologic findings.

The accuracy of fine-needle aspiration (FNA) cytologic diagnosis of nonpalpable breast lesions and the prevalence of neoplasm occurring in areas unrelated to the radiologic abnormality were studied. Template-guided FNA cytologic examination was performed in 101 surgically excised breast specimens. The exact area of the mammographic abnormality was aspirated with radiographic control. Despite accurate placement of the needle for aspiration, seven of 101 aspirates (7%) yielded insufficient cytologic material. Ninety-four of the 101 aspirates (93%) were adequate for diagnosis. The cytologic diagnosis was benign in 58 (62%), atypical in seven (7%), suspicious for malignancy in four (4%), and malignant in 25 (27%). All cases diagnosed as suspicious or malignant and five of 58 cases diagnosed as benign at cytologic examination proved to be malignant at histologic examination. In three of these five the malignancy was in the area of the radiologic abnormality; in two it was not. FNA cytologic examination can be helpful in evaluating nonpalpable breast lesions, but it is not as accurate as histologic examination of surgically excised lesions.

Biopsy, Needle

CT diagnosis of cecal herniation through the foramen of Winslow.

The computed tomographic (CT) appearance of a case of cecal herniation through the foramen of Winslow is described. This is an extremely uncommon type of internal hernia, and, to the best of our knowledge, its CT appearance has not been reported. Its recognition is important to both establish a preoperative diagnosis and to distinguish it from a lesser sac collection or abscess.

Adult

Diagnostic quality of mammograms obtained with a new low-radiation-dose dual-screen and dual-emulsion film combination.

We evaluated the image quality of mammograms made by using a new dual-screen, dual-emulsion film combination (Kodak Min-R Fast screen, T-Mat Mll film) that permits reduction of radiation exposure by approximately 50% when compared with a standard single-screen, single-emulsion film system (Kodak Min-R screen, OM-1 film). This new film has been improved when compared with earlier T-Mat M film, including the introduction of an inert dye to reduce light crossover to essentially 0%. Mammogram pairs made with the dual-emulsion film combination and the standard single-emulsion film combination were obtained in 50 patients otherwise undergoing routine mammography. The image pairs were randomized and evaluated by three radiologists who used a three-point scale (better, same, or worse). Each pair was evaluated with regard to parenchymal contrast, sharpness, and latitude, as well as the number and sharpness of calcifications (n = 19) and sharpness of masses (n = 12) when present. All three observers found the dual-emulsion film combination to be better than or the same as the standard with regard to parenchymal sharpness (94-100%), the number and sharpness of calcifications (98-100%), and sharpness of masses (100%). Two observers found the dual-emulsion film combination to be significantly worse (p less than .05) than the standard with respect to parenchymal contrast (72%, 86%), and all three observers rated it significantly worse for film latitude (14 to 42%). Our results suggest that this new dual-emulsion film combination that allows mammography to be performed with less radiation exposure can be used without loss of image quality.

Breast

Echinococcal hepatic disease: magnetic resonance appearance.

The magnetic resonance (MR) appearance of an echinococcal hepatic cyst is described. A previous report has suggested that a low-intensity rim surrounding the cyst may be useful in differentiating hydatid cysts from other hepatic lesions. No such rim was identified in our case; however, MR was found to be superior to other modalities in delineating the internal contents of the hydatid cyst.

Diagnosis, Differential

Appendicitis with bladder involvement: CT appearance.

A case of appendicitis presenting with microscopic hematuria and a suprapubic mass involving the bladder is described. Computed tomography (CT) is a valuable aid in the diagnosis of atypical or otherwise unsuspected appendicitis. Besides first suggesting the diagnosis of appendicitis, CT was also able to demonstrate the full extent of the inflammatory process preoperatively in this case.

Adult