PubMed Health⌕ Search

Biomedical subjects

D Abe

Publications and source records attributed to D Abe.

10 recordsLinked to original sources

Tissue factor expression as a possible determinant of thromboembolism in ovarian cancer.

Ovarian cancer, and clear cell carcinoma in particular, reportedly increases the risk of venous thromboembolism (VTE). However, the mechanisms remain unclear. Tissue factor (TF) supposedly represents a major factor in the procoagulant activities of cancer cells. The present study examined the involvement of TF expression in VTE for patients with ovarian cancer. Subjects comprised 32 consecutive patients (mean age 49.8 years) with histologically confirmed ovarian cancer. Presence of VTE was examined using a combination of clinical features, D-dimer levels and venous ultrasonography. Immunohistochemical analysis was used to evaluate TF expression into 4 degrees. Venous thromboembolism was identified in 10 of the 32 patients (31%), including five of the 11 patients with clear cell carcinoma. Tissue factor expression was detected in cancer tissues from 24 patients and displayed significant correlations with VTE development (P=0.0003), D-dimer concentration (P=0.003) and clear cell carcinoma (P<0.05). Multivariate analysis identified TF expression as an independent predictive factor of VTE development (P<0.05). Tissue factor (TF) expression is a possible determinant of VTE development in ovarian cancer. In particular, clear cell carcinoma may produce excessive levels of TF and is more likely to develop VTE.

Adolescent↗

Vibrational energy relaxation of naphthalene in the S(1) state in various gases.

Time-resolved fluorescence spectra of naphthalene in the S(1) state have been measured in various gases below 10(2) kPa. The band shape of the fluorescence changed in an earlier time region after the photoexcitation when an excess energy (3300 cm(-1)) above the 0-0 transition energy was given. The excitation energy dependence of the fluorescence band shape of an isolated naphthalene molecule was measured separately, and the time dependence of the fluorescence band shape in gases was found to be due to the vibrational energy relaxation in the S(1) state. We have succeeded in determining the transient excess vibrational energy by comparing the time-resolved fluorescence band shape with the excitation energy dependence of the fluorescence band shape. The excess vibrational energy decayed almost exponentially. From the slope of the decay rate against the buffer gas pressure, we have determined the collisional decay rate of the excess vibrational energy in various gases. The dependence of the vibrational energy relaxation rate on the buffer gas species was similar to the case of azulene. The comparisons with the results in the low temperature argon and the energy relaxation rate in the S(0) state in nitrogen were also discussed.

Journal Article↗

Sigma-nucleus potential in A=28.

We have studied the (pi(-),K+) reaction on a silicon target to investigate the sigma-nucleus potential. The inclusive spectrum was measured at a beam momentum of 1.2 GeV/c with an energy resolution of 3.3 MeV (FWHM) by employing the superconducting kaon spectrometer system. The spectrum was compared with theoretical calculations within the framework of the distorted-wave impulse approximation, which demonstrates that a strongly repulsive sigma-nucleus potential with a nonzero size of the imaginary part reproduces the observed spectrum.

Journal Article↗

Measurement of the B(e2) of (7)(lambda)Li and shrinkage of the hypernuclear size.

We report on the first measurement of a hypernuclear gamma-transition probability. gamma rays emitted in the E2(5/2(+)-->1/2(+)) transition of (7)(Lambda)Li were detected by a large-acceptance germanium detector array (Hyperball), and the lifetime of the parent state ( 5/2(+)) was determined by the Doppler shift attenuation method. The obtained result, 5.8(+0.9)(-0.7)+/-0.7 ps, was then converted into the reduced transition probability [ B(E2)] to be B(E2;5/2(+)-->1/2(+)) = 3.6+/-0.5(+0.5)(-0.4) e(2) fm(4). Compared with the B(E2) of the corresponding E2(3(+)-->1(+)) transition in the 6Li nucleus, our result gives evidence that the size of the 6Li core in (7)(Lambda)Li is smaller than the 6Li nucleus in the free space.

Journal Article↗

Field testing of VO2peak in cross-country skiers with portable breath-by-breath system.

Peak aerobic exercise responses were determined in 8 competitive cross-country skiers during field-testing and during an incremental treadmill test (TM) to determine peak oxygen uptake (VáO2peak), heart rate, and oxygen pulse. Field testing consisted of maximal effort roller skiing using diagonal stride (DS) and double poling (DP) techniques. VáO2 was measured during roller skiing by the portable Cosmed K4b2 breath-by-breath system. The portable system was compared against a standard laboratory mixing box system, and no differences were found across the full range of VáO2. During DS, VáO2peak and oxygen pulse were not different from TM, whereas peak HR was lower. With DP, VáO2peak and oxygen pulse were less than DS or TM, whereas peak HR was less than with TM but not different from DS. These results demonstrate the validity and utility of the portable breath-by-breath system for measurement of aerobic energy demand of athletes as they carry out their normal activity.

Exercise Test↗

Observation of a spin-flip M1 transition in 7(lambda)Li.

Using a large-acceptance germanium detector array (Hyperball), we have observed a spin-flip M1 gamma transition between the ground-state spin doublet of (7)(Lambda)Li (3/2(+)-->1/2(+)). The observed energy of 691.7+/-0.6(stat)+/-1.0(syst) keV provides crucial information on the strength of the spin-spin interaction between a Lambda and a nucleon. This is the first observation of well-identified hypernuclear gamma transitions using germanium detectors.

Journal Article↗

Assessment of long-distance running performance in elite male runners using onset of blood lactate accumulation.

The purpose of this study was to evaluate the relationship between onset of blood lactate accumulation (OBLA) and long-distance running performance in order to examine whether OBLA can be a good predictor of long-distance running performance even in elite male runners with similar performance levels. Eleven highly-trained male long-distance runners participated in this study. The average running velocities of the individuals' running performance were 5.918 +/- 0.084 m.s-1 and 5.672 +/- 0.095 m.s-1 for 5000 m (V5000) and 10,000 m (V10000), respectively. The blood lactate concentrations and heart rate responses were measured immediately after field running, and the average value of running velocity corresponding to OBLA (VOBLA) was 5.447 +/- 0.132 m.s-1. Variations of these three velocities expressed as a coefficient of variance (CV) ranged from 1.4 to 2.4%. A strong inverse relationship between heart rate corresponding to OBLA (HROBLA) and performance was observed (r = -0.709, p < 0.02 for V5000 and r = -0.830, p < 0.01 for V10000), while there was a lack of significant relationship between VOBLA and performance (r = 0.293, NS for V5000 and r = 0.130, NS for V10000). Furthermore, the average value of HROBLA obtained in this study (174.5 +/- 8.2 b.min-1) was quite similar to that of the heart rate threshold reported by some previous researchers. In conclusion, VOBLA alone could not explain the small variation of long-distance running performance, and HROBLA should be used in place of VOBLA for evaluating long-distance running performance in elite runners with quite similar performance levels.

Adult↗

Assessment of middle-distance running performance in sub-elite young runners using energy cost of running.

The purpose of this study was to assess the validity of v(amax) as an indicator of middle-distance running performance in sub-elite young runners, v(amax) being defined as the quotient maximal oxygen uptake (VO2max) divided by the net energy cost of running (Cr) on a treadmill at a submaximal running velocity (280 m x min[-1]). The VO2max, ventilatory threshold, v(amax), and Cr were assessed in 39 young male sub-elite runners having only small variations in performance level. The relationship between each variable and running performance (at 1500 m, 3000 m, and 5000 m) was evaluated. A trend toward a negative correlation existed between Cr and performance although this was not significant. The VO2max and v(amax) were significantly related to performance. The v(amax) accounted for around 50% of the variability in performance whereas other physiological variables selected in this study were responsible, at best, for approximately 39%. The results presented in this study suggested that v(amax) was a useful indicator of middle-distance running performance in sub-elite young runners with similar performance levels as well as in top elite athletes.

Adolescent↗