Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Algorithms↗

Photo-cross-linkable oligonucleotide probes for in situ hybridization assays.

In situ hybridization techniques have been an important research tool since first introduced 30 years ago, and more recently clinical applications have been expanding greatly. Still, further improvements in the assay sensitivity and protocols that are amenable to routine clinical use are desired. We use a novel photo-cross-linking technology to irreversibly bind short oligonucleotide probes to the target sequence following a hybridization period. The cross-linking agent is incorporated into the backbone of the probe and is activated to react with pyrimidines in the opposite strand by near-UV (300-370 nm) irradiation. By locking the probe to the target, very stringent wash conditions can be used that would otherwise completely remove probes that are hybridized but not cross-linked to the target. Consequently, the probe-specific signal is maximized, while the background signal is minimized to the greatest extent possible with the stringency of the wash. The use of short, photo-cross-linkable probes presents a new strategy for maximizing the sensitivity of probe hybridization or signal amplification-based in situ techniques.

Base Sequence↗

Digital tomosynthesis in breast imaging.

PURPOSE: To describe and evaluate a method of tomosynthesis breast imaging with a full-field digital mammographic system. MATERIALS AND METHODS: In this tomosynthesis method, low-radiation-dose images were acquired as the x-ray source was moved in an arc above the stationary breast and digital detector. A step-and-expose method of imaging was used. Breast tomosynthesis and conventional images of two imaging phantoms and four mastectomy specimens were obtained. Three experienced readers scored the relative lesion visibility, lesion margin visibility, and confidence in the classification of six lesions. RESULTS: Tomosynthesis image-reconstruction algorithms allow tomographic imaging of the entire breast from a single arc of the x-ray source and at a radiation dose comparable with that in single-view mammography. Except for images of a large mass in a fatty breast, the tomosynthesis images were superior to the conventional images. CONCLUSION: Digital mammographic systems make breast tomosynthesis possible. Tomosynthesis may improve the specificity of mammography with improved lesion margin visibility and may improve early breast cancer detection, especially in women with radiographically dense breasts.

Female↗

The thermoelastic basis of short pulsed laser ablation of biological tissue.

Strong evidence that short-pulse laser ablation of biological tissues is a photomechanical process is presented. A full three-dimensional, time-dependent solution to the thermoelastic wave equation is compared to the results of experiments using an interferometric surface monitor to measure thermoelastic expansion. Agreement is excellent for calibrations performed on glass and on acrylic at low laser fluences. For cortical bone, the measurements agree well with the theoretical predictions once optical scattering is included. The theory predicts the presence of the tensile stresses necessary to rupture the tissue during photomechanical ablation. The technique is also used to monitor the ablation event both before and after material is ejected.

Animals↗

Mechanisms of meniscal tissue ablation by short pulse laser irradiation.

A new experimental technique was developed to study short-pulsed laser ablation of biologic tissues (human meniscus and bovine tibial bone), water, and acrylic. The experimental technique was based on interferometric monitoring of the motion of the tissue surface to measure its laser-induced expansion after irradiation. The thermoelastic expansion of these materials after laser irradiation under subablation threshold was examined to determine its role in the initiation of ablation. The experimentally observed surface expansion of cortical bone and acrylic was in agreement with theoretical predictions. The movement of meniscal tissue was similar to that shown by water. The latter 2 materials showed additional features consistent with the growth and collapse of cavitation bubbles. The exact role of cavitation in the irradiation of meniscal tissue by laser light remains unknown, but may represent a clinically important mode of tissue ablation and postirradiation trauma.

Animals↗

Interferometric surface monitoring of biological tissue to study inertially confined ablation.

We present results from the application of laser interferometry to the study of short-pulsed laser ablation of biological tissue. The mechanical response of tissue to laser-induced stress is examined under subthreshold conditions to determine its role in initiating the ablation process. A theoretical model is developed to relate this surface displacement to the pressure within the tissue and the mechanical properties of the tissue. In the experiment, a 7.5 ns pulse of 355 nm light was used to irradiate bovine shank bone, human meniscus, and an aqueous dye solution. Interferometric monitoring of the tissue surface was used to determine its motion after laser irradiation. The surface movement of bone was qualitatively consistent with the theoretical predictions of the model. The movement of meniscus and an aqueous dye solution showed additional features that are consistent with the growth and collapse of cavitation bubbles.

Animals↗

Laser-induced thermoelastic deformation: a three-dimensional solution and its application to the ablation of biological tissue.

Under certain conditions, laser light incident on a target material can induce an explosive removal of some material, a process called laser ablation. The photomechanical model of laser ablation asserts that this process is initiated when the laser-induced stresses exceed the strength of the material in question. Although one-dimensional calculations have shown that short pulsed lasers can create significant transient tensile stresses in target materials, the stresses last for only a few nanoseconds and the spatial location of the peak stresses is not consistent with experimental observations of material failure in biological tissues. Using the theory of elasticity, analytical expressions have been derived for the thermoelastic stresses and deformations in an axially symmetric three-dimensional solid body caused by the absorption of laser light. The full three-dimensional solution includes three stresses, radial, circumferential and shear, which are necessarily absent in the simple one-dimensional solution. These stresses have long-lived components that exist for eight orders of magnitude longer in time than the acoustic transients, an important point when the details of dynamic fracture are considered. Many important qualitative features are revealed including the spatial location of the peak stresses, which is more consistent with experimental observations of failure.

Animals↗

Wavelength dependence of pulsed laser ablation of calcified tissue.

Pulsed laser ablation of calcified biological tissue was studied at several wavelengths in the near-ultraviolet, visible, near- and mid-infrared regions of the spectrum. The primary tissue model was bovine shank bone, while human arterial calcified plaque and normal human artery wall were also studied at selected wavelengths for comparison. Laser irradiances were on the order of MW/mm2, fluences ranged up to 1000 mJ/mm2, and repetition rates varied between 0.3-10 Hz. Spot sizes on the tissue surface ranged from 150 to 850 microns. Laser craters made with wavelengths between lambda = 295 nm and lambda = 375 nm and in the lambda = 3 microns region exhibited the highest quality ablation with clean, sharp cuts following closely the spatial contour of the incident beam. Craters drilled with visible wavelengths between lambda = 450 nm and lambda = 590 nm were generally larger than the incident laser beam spot, irregular in shape and often surrounded by large flakes of tissue debris. Ablation fluence thresholds increased with wavelength through the visible wavelengths and into the mid-infrared, but dropped to their lowest values near lambda = 3 microns. Fluence thresholds obtained with the tissue under a 1 mm depth of saline were approximately twice air thresholds. Ablation yields also varied with wavelength, probably due to increased scattering in the visible region, and were the same under saline as in air.

Absorption↗